• Title/Summary/Keyword: Function Transfer

Search Result 3,374, Processing Time 0.031 seconds

Attenuation of Experimental Autoimmune Hepatitis in Mice with Bone Mesenchymal Stem Cell-Derived Exosomes Carrying MicroRNA-223-3p

  • Lu, Feng-Bin;Chen, Da-Zhi;Chen, Lu;Hu, En-De;Wu, Jin-Lu;Li, Hui;Gong, Yue-Wen;Lin, Zhuo;Wang, Xiao-Dong;Li, Ji;Jin, Xiao-Ya;Xu, Lan-Man;Chen, Yong-Ping
    • Molecules and Cells
    • /
    • v.42 no.12
    • /
    • pp.906-918
    • /
    • 2019
  • MicroRNA-223-3p (miR-223-3p) is one of the potential microRNAs that have been shown to alleviate inflammatory responses in pre-clinical investigations and is highly encased in exosomes derived from bone mesenchymal stem cells (MSC-exosomes). MSC-exosomes are able to function as carriers to deliver microRNAs into cells. Autoimmune hepatitis is one of the challenging liver diseases with no effective treatment other than steroid hormones. Here, we examined whether MSC-exosomes can transfer miR-223-3p to treat autoimmune hepatitis in an experimental model. We found that MSC-exosomes were successfully incorporated with miR-223-3p and delivered miR-223-3p into macrophages. Moreover, there was no toxic effect of exosomes on the macrophages. Furthermore, treatments of either exosomes or exosomes with miR-223-3p successfully attenuated inflammatory responses in the liver of autoimmune hepatitis and inflammatory cytokine release in both the liver and macrophages. The mechanism may be related to the regulation of miR-223-3p level and STAT3 expression in the liver and macrophages. These results suggest that MSC-exosomes can be used to deliver miR-223-3p for the treatment of autoimmune hepatitis.

Abosrbed Dose Measurements and Phantom Image Ecaluation at Minimum CT Dose for Pediatric SPECT/CT Scan (소아 SPECT/CT 검사를 위한 최저조건에서의 피폭선량측정 및 팬텀의 영상평가)

  • Park, Chan Rok;Choi, Jin Wook;Cho, Seong Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.82-88
    • /
    • 2014
  • Purpose: The purpose of study was to evaluate radiation dose for pediatric patients by changing tube voltage (kVp) and tube current (mA) at minimum conditions. By evaluating radiation dose, we want to provide dose reduction for pediatric patients and maintain good quality of SPECT/CT images. Materials and Methods: Discovery NM/CT 670 Scanne was used as SPECT/CT. Tube voltages are 80 and 100 kvP. Tube currents are 10, 15, 20, 25 mA. Using PMMA (Polymethyl methacrylate) Phantom, radiation dose which were calculated at center and peripheral dose and SNRD (Signal to Noise Ratio Dose) were evaluated. Using the CT performance phantom, spatial resolution was evaluated as the MTF (Modulation Transfer Function) graph. Jaszczak phantom was used for SPECT image evaluation by CNR (Contrast to Noise to Ratio). Results: Radiation dose using the PMMA phantom was higher peripheral dose than center dose about 7%. SNRD were 7.8, 8.2, 8.3, 8.8, 8.8, 9.9, 9.8, 9.6 for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. We can distinguish 35, 45, 70, 71, 52, 58, 90, 110 linepair for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA at resolution with MTF. CNR of SPECT images using CT attenuation map were 57.8, 57.7, 57.1, 56.7, 56.6, 56.7, 56.7, 56.7% for 80 kVp 10, 15, 20, 25 mA, 100 kVp 10, 15, 20, 25 mA. Conclusion: In this study, radiation dose for pediatric patients showed decreased low dose condition. And SNRD value was similar in all condition. Resolution showed higher value at 100kVp than 80kVp. for CNR, there was no significant difference. we should take additional study to prove better quality and dose reduction.

  • PDF

Design and Implementation of Medical Information System using QR Code (QR 코드를 이용한 의료정보 시스템 설계 및 구현)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • The new medical device technologies for bio-signal information and medical information which developed in various forms have been increasing. Information gathering techniques and the increasing of the bio-signal information device are being used as the main information of the medical service in everyday life. Hence, there is increasing in utilization of the various bio-signals, but it has a problem that does not account for security reasons. Furthermore, the medical image information and bio-signal of the patient in medical field is generated by the individual device, that make the situation cannot be managed and integrated. In order to solve that problem, in this paper we integrated the QR code signal associated with the medial image information including the finding of the doctor and the bio-signal information. bio-signal. System implementation environment for medical imaging devices and bio-signal acquisition was configured through bio-signal measurement, smart device and PC. For the ROI extraction of bio-signal and the receiving of image information that transfer from the medical equipment or bio-signal measurement, .NET Framework was used to operate the QR server module on Window Server 2008 operating system. The main function of the QR server module is to parse the DICOM file generated from the medical imaging device and extract the identified ROI information to store and manage in the database. Additionally, EMR, patient health information such as OCS, extracted ROI information needed for basic information and emergency situation is managed by QR code. QR code and ROI management and the bio-signal information file also store and manage depending on the size of receiving the bio-singnal information case with a PID (patient identification) to be used by the bio-signal device. If the receiving of information is not less than the maximum size to be converted into a QR code, the QR code and the URL information can access the bio-signal information through the server. Likewise, .Net Framework is installed to provide the information in the form of the QR code, so the client can check and find the relevant information through PC and android-based smart device. Finally, the existing medical imaging information, bio-signal information and the health information of the patient are integrated over the result of executing the application service in order to provide a medical information service which is suitable in medical field.

Importance of Carbon Monoxide Transfer Coefficient (KCO) Interpretation in Patients with Airflow Limitation (기류제한 환자의 일산화탄소확산능 해석에서 폐용적 보정의 의의)

  • Seo, Yong Woo;Choi, Won-Il;Lee, Jeong Eun;Park, Hun Pyo;Ko, Sung Min;Won, Kyoung Sook;Keum, Dong Yoon;Lee, Mi-Young;Jeon, Young June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.374-379
    • /
    • 2005
  • Background : The single-breath carbon monoxide diffusion capacity (DLCO) and the per unit alveolar volume (KCO; $D_LCO/VA$) gave discordant values when there was an abnormal alveolar volume (VA). However, the clinical significance of the discordant values in patients with airflow limitation has not been examined. This study investigated the $D_LCO$ and KCO changes after improving the airflow limitation. Methods : The baseline $D_LCO$ and KCO with lung volume were measured in patients with an airflow obstruction. The effective alveolar volume was measured using the single-breath $CH_4$ dilution method. The patients divided into two groups according to the baseline values: (1) increased KCO in comparison with the $D_LCO$ (high discordance) (2) decreased or not increased KCO in comparison with the $D_LCO$ (low discordance). The diffusion capacity and lung volume were measured after treatment. Results : There was no significant difference in the baseline lung volumes including the $FEV_1$ and FVC between the two groups. The $FEV_1$ and FVC were significantly increased in the high discordance group compared with the low discordance group after treating the airflow limitation. The $D_LCO$ and alveolar volume were significant higher in the high discordance group compared with the low discordance group while the TLC was not. Conclusion : The discordance between the $D_LCO$ and KCO could be translated into an airflow reversibility in patients with an airflow limitation.

A Research on Ball-Balancing Robot (볼 벨런싱 로봇에 관한 연구)

  • Kim, Ji-Tae;Kim, Dae-young;Lee, Won-Joon;Jin, Tae-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.463-466
    • /
    • 2017
  • The purpose of this paper is to develop a module capable of all-directional driving different from conventional wheeled robots, and to solve the problems of the conventional mobile robot with side driving performance degradation, It is possible to overcome the disadvantages such as an increase in the time required for the unnecessary driving. The all - direction spherical wheel drive module for driving a ball - balancing robot is required to develop a power transfer mechanism and a driving algorithm for driving the robot in all directions using three rotor casters. 3DoF (Axis) A driver with built-in forward motion algorithm is embedded in the module and a driving motor module with 3DoF (axis) for driving direction and speed is installed. The movement mechanism depends on the sum of the rotation vectors of the respective driving wheels. It is possible to create various movement directions depending on the rotation and the vector sum of two or three drive wheels. It is possible to move in different directions according to the rotation vector field of each driving wheel. When a more innovative all-round spherical wheel drive module for forward movement is developed, it can be used in the driving part of the mobile robot to improve the performance of the robot more technically, and through the forward-direction robot platform with the drive module Conventional wheeled robots can overcome the disadvantage that the continuous straightening performance is lowered due to resistance to various environments. Therefore, it is necessary to use a full-direction driving function as well as a cleaning robot and a mobile robot applicable in the Americas and Europe It will be an essential technology for guide robots, boarding robots, mobile means, etc., and will contribute to the expansion of the intelligent service robot market and future automobile market.

  • PDF

Latarjet Operation for Anterior Shoulder Instability with Glenoid Bone Defect (관절와 골 결손을 동반한 견관절 전방 불안정증에 대한 Latarjet 술식)

  • Cho, Seung-Hyun;Cho, Nam-Su;Yi, Jin-Woong;Choi, Il-Hun;Kwack, Yoon-Ho;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.189-198
    • /
    • 2009
  • Purpose: We wanted to evaluate the clinical results of the Latarjet procedure for treating anterior shoulder instability combined with a glenoid bone defect. Materials and Methods: Between Oct. 2006 and May. 2007, fourteen patients underwent a Latarjet operation to treat their anterior shoulder instability combined with a glenoid bone defect. The mean follow-up period was 15 months (range: 12 to 19 months), and the average age at the time of surgery was 29.9-years-old (range: 19 to 44 years). There were 13 males and 1 female. Eight patients exhibited involvement of the right shoulder. The dominant arm was involved in 8 patients. Six patients had undergone a previous arthroscopic Bankart repair before their Latarjet operation and 2 patients had a history of seizure. Results: The average Rowe score improved from 51.8 to 80.2 with 9 excellent, 4 good, and 1 fair results. The average Korean shoulder score for instability improved from 61.6 to 82.1 postoperatively. The active forward flexion and external rotation at the side of the involved shoulder was an average of $8^{\circ}$ and $16^{\circ}$ less than that of the uninvolved shoulder. The muscle strength of the involved shoulder measured 78.7% in forward flexion and 82.5% in external rotation, as compared with that of the uninvolved shoulder. There was 1 case of dislocation, 1 transient subluxation, 2 fibrotic unions, 1 resorption of the transferred coracoid process, 1 intraoperative broken bone, 1 transient musculocutaneous nerve injury and 1 case of stiffness. Conclusion: The Latarjet procedure for treating anterior shoulder instability combined with a significant glenoid defect effectively restores function and stability through extending the articular arc at the expense of external rotation. We should be cautious to avoid or detect complications when performing coracoid transfer.

Classification of Estuaries based on Morphological Convergence (형태적 수렴 특성을 이용한 하구 분류)

  • SHIN, Hyun-jung;RHEW, Hosahng;LEE, Guan-hong
    • Journal of The Geomorphological Association of Korea
    • /
    • v.19 no.3
    • /
    • pp.1-22
    • /
    • 2012
  • The classification scheme of estuaries can be divided into two categories: qualitative classification based on geomorphic characteristics and quantitative classification based upon the physical properties of water body. While simple and intuitive scheme of the former is difficult to quantify, the latter is not easy to apply due to the lack of data. A classification scheme based on morphological convergence is very promising because it only requires easily accessible data such as width and depth of channels, as well as it can characterize estuaries in terms of tidal propagation. Thus, this paper examines the classification scheme based on estuarine morphological convergence using depth and width data obtained from 19 major Korean estuaries. Morphological convergence for each estuary was estimated with the estuarine length, width and depth data to get the convergence parameters, which includes the degree of funneling ${\nu}$ and the dimensionless estuarine length $y_0$. The transfer function ${\xi}({\nu},ky)$ is then deduced analytically from 1D depth-integrated hydrodynamic momentum equation and continuity equation for estuarine shapes. Tidal response of each estuary is finally calculated using ${\nu}$, $y_0$ and ${\xi}({\nu},ky)$ for comparison and classification. The 19 Korean estuaries were classified into three groups: tidal amplitude-dominated estuaries with standing wave-like tidal response (group 1), current-dominated estuaries with progressive wave-like tidal response (group 2), and the intermediate group (group 3) between groups 1 and 2. The sensitivity analysis revealed that uncertainties in determining the estuarine length can have a critical effect upon the results of classification, which indicates that the reasonable determination of the estuarine length is of critical importance. Once the estuarine length is feasibly determined, depth-convergence can be neglected without any negative effect on the classification scheme, which has an important ramification on the wide applicability of the classification scheme.

The long-term decay rate and nutrient dynamics during leaf litter decomposition of Pinus densiflora and Pinus thunbergii (한반도 중부지역 조림지 소나무와 곰솔의 장기적 낙엽 분해율 및 분해과정에 따른 영양염류 동태변화)

  • Lee, Il-hwan;Jo, Soo-un;Lee, Young-sang;Won, Ho-yeon
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.3
    • /
    • pp.374-382
    • /
    • 2021
  • In the present study, we analyzed the decay rate and nutrient dynamics during leaf litter decomposition of Pinus densiflora and Pinus thunbergii in Gongju for 60 months, from 2014 to 2019. P. thunbergii leaf litter decomposed faster than that of P. densiflora. The decay constant of P. densiflora and P. thunbergii leaf litter after 60 months was 3.02 and 3.59, respectively. The initial C/N ratio of P. densiflora and P. thunbergii leaf litter were 14.4 and 14.5, respectively. After 60 months, C/N ratio of decomposing P. densiflora and P. thunbergii leaf litter decreased to 2.26 and 3.0, respectively. The initial C/P ratio of P. densiflora and P. thunbergii leaf litter were 144.1 and 111.3. After 60 months elapsed, the C/P ratio of decomposing P. densiflora and P. thunbergii leaf litter decreased to 40.1 and 45.8, respectively. After 60 months, the percentage of the remaining N, P, K, Ca, and Mg in decomposing P. densiflora leaf litter was 231.08, 130.13, 35.68, 48.58, and 36.03%, respectively. After 60 months, the percentage of the remaining N, P, K, Ca, and Mg in decomposing P. thunbergii leaf litter was 143.91, 74.02, 28.59, 45.08, and 44.99%, respectively. The findings of the present study provide an insight into the forest ecosystem function of coniferous forests through the analysis of the amount of nutrient transfer into the soil through a long-term decomposition process; this information is intended to be used as basic data for preparing counter measures for future climate and ecosystem changes.

The Reform of the National Records Management System and Change of Administrative System in Korean Government from 1948 to 1964 (한국정부 수립 이후 행정체제의 변동과 국가기록관리체제의 개편(1948년~64년))

  • Lee, Sang-Hun
    • The Korean Journal of Archival Studies
    • /
    • no.21
    • /
    • pp.169-246
    • /
    • 2009
  • The national records management system of the Korean Government has been developed in a close relationship with changes in the administrative system. The national records management system established immediately after the establishment of the Korean Government, began to be reformed as a system with a new feature during the quick transition of the administrative system during the early 1960s. Particularly this new system holds an important meaning in that it began to cope with the mass production system of records and was established on the government level for the first time since the establishment of the government. Also this was a basic framework that defined the records management pattern of the Korean Government for the later 40 years. Therefore, this study aims to identify the origin and the meaning of the national records management system established during the early 1960s. At the time of establishing the government, the administrative system of the Korean Government was not completely free from the framework of the administrative system of the Chosen General Government. This was mainly because the Korean Government had no capability to renovate the administrative system. This was not an exception also for the national records management system. In other words, the forms and preparation methods of official document, an official document management process, and the classification and appraisal system used the records management system of the Chosen General Government without any alteration. Main factors that brought about the reform of the national records management system as well as the change in the Korean administrative system during the early 1960s, were being created in Korean society, starting from the mid 1950s. This resulted from the growth of Korean Army, public officers, and students of administrative science as being the intrinsic elites of Korean society through their respective experience of the US administration. In particular, the reform of the creation, classification, filing, transfer, and preservation system shown during the introduction of a scientific management system of the US Army in the Korean Army was a meaningful change given the historic developing process of Korean records management system history. This change had a decisive effect on the reform of the national records management system during the early 1960s. As the Korean Army, public officers, and students of administrative science, who had posted growth beginning in the mid-1950s, emerged as administrative elites during the early 1960s, the administrative system of the Korean Government brought about a change, which was different from the past in terms of its quality, and the modernization work of documentary administration pursued during the period, became extended to the reform of the national records management system. Then, the direction of reform was 'the efficient and effective control' over records based on scientific management, which was advanced through the medium of the work that accommodate the US office management system and a decimal filing system to Korean administrative circumstances. Consequently, Various official document forms, standards, and the gist of process were improved and standardized, and the appraisal system based on the function-based classification were unified on the government level by introducing a decimal filing system.

A Study on Inscribed Celadons Excavated from the Goryeo Palace Site (고려궁성 출토 명문·기호 청자 고찰)

  • Park, Jiyoung
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.2
    • /
    • pp.122-141
    • /
    • 2019
  • This study aimed to provide new interpretations of the ceramics excavated from the archaeological site of the royal palace of Goryeo (918~1392), where only limited access was permitted due to its location in Gaeseong, North Korea. The interpretations were based on the existing understanding of the arrangement of the palace buildings at the site and historical records. The study of the general aspects of the celadons discovered during eight excavations at the Goryeo Palace site in Gaeseong revealed that most of the vessels found at the site were produced during the early and middle phases of the Goryeo dynasty. The study involved classifying the celadons bearing inscribed texts and symbols into 18 different types according to their characteristic features and periods of production. The inscribed celadons have provided detailed information of the site where they were found, thereby making it possible to make strong presumptions about the date of construction, function, and status of the building in the palace connected with the discoveries. The excavations from the Goryeo Palace site and related historical literature suggest that the celadons bearing the inscription "Sojeon (燒錢)" were used during the first half of the 13th century, although the existing view had been that they were used during the second half of the century. This new conclusion is based on the use of the symbols ${\circ}$ and ${\odot}$, the celadons found together with the Sojeon-inscribed celadons, the date of the celadons bearing the inscription "Seong (成)," and the location of their discovery behind the site of Seongyeongjeon (aka Hoegyeongjeon) Hall, which had been one of the main palace buildings. The Taoist rituals performed for the safety of the Goryeo dynasty were largely held at Ganganjeon (aka Daegwanjeon) Hall in the western part of the royal palace during the second half of the 13th century. It was mostly in the first half of the 13th century just before the transfer of the Goryeo government from Gaeseong to Ganghwa (1232~1270) that the Taoist rituals were held at the location near Seongyeongjeon Hall, where archaeologists found the Sojeon-inscribed celadons. Therefore, the large number of celadon cups with holders, including those inscribed with Sojeon, discovered during the eighth excavation of the palace site suggests that they were used for the rituals held at Seongyeongjeon Hall during the first half of the 13th century.