• Title/Summary/Keyword: Fume

Search Result 793, Processing Time 0.029 seconds

A Study on the Fundamental Properties of High Strength Concrete Using Silica Fume (실리카흄 사용 고강도콘크리트의 기초적 성질에 대한 연구)

  • 문한영;김기형;문대중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.11-17
    • /
    • 1993
  • In this study, the fundamental properties of High-Strength Concrete(HSC), such as the slump loss, the temperature increment, the strength development, are considered by experiment. In reducing the temperature and the slump loss, and developing the strength of HSC, the application of silica fume as an admixtures is very effective. And when gypsum is added, the slump loss is reduced and the strength of HSC is improved remarkably, but the temperature of concrete is increased, thus a more study to reduce the temperature increment is required

  • PDF

Strength Charcteristics of Centrifugal Pipes With Silica Fume Concrete (실리카흄을 혼입한 원심력 콘크리트관의 강도특성)

  • Kim, Tae-Kyung
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.31-38
    • /
    • 1996
  • This experimental study was conducted to analyze the characteristics of centrifugal pipes which were made of silica fume concrete. External load tests showed that maximum external load ranged from 1,100~5,300kgf/m with thickness ratio(t/D) of between 4.5%~10.0%. Correlation between thickness ratios and external loads was excellent with $R^2$ of 0.99. Respective correlation between measured and computed vertical deformation was good with $R^2$ of higher than 0.90. And therefore, vertical deformation and tensile stress of centrifugal concrete pipes may be theoretically computed with a good precision.

  • PDF

A Study on the Fundamental Properties of High-Strength Concrete using Silica Fume (실리카흄 혼합 고강도 콘크리트의 기초물성에 관한 연구)

  • 문한영;김진철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.10a
    • /
    • pp.21-25
    • /
    • 1991
  • For the purpose of improving the compressive strength of concrete, the high strength concrete which have the compressive strength about 800kg/$\textrm{cm}^2$ were made by using silica fume and high range water reducing admixture on reducing the water-cement ratio. But the facts that the slump loss of high strength concrete was high and the tensile strength and elastic modulus were not improved enough are indicated to problems which must be solved.

  • PDF

Outbreak of Sudden Cardiac Deaths in a Tire Manufacturing Facility: Can It Be Caused by Nanoparticles?

  • Kim, Eun-A;Park, Jung-Sun;Kim, Kun-Hyung;Lee, Na-Roo;Kim, Dae-Seong;Kang, Seong-Kyu
    • Safety and Health at Work
    • /
    • v.3 no.1
    • /
    • pp.58-66
    • /
    • 2012
  • Objectives: The purpose of this study was to review clinical characteristics and working environments of sudden cardiac death (SCD) cases associated with a tire manufacturer in Korea, and review possible occupational risk factors for cardiovascular disease including nanoparticles (ultrafine particles, UFPs). Methods: We reviewed (i) the clinical course of SCD cases and (ii) occupational and non-occupational risk factors including chemicals, the physical work environment, and job characteristics. Results: Possible occupational factors were chemicals, UFPs of rubber fume, a hot environment, shift work, overworking, and noise exposure. The mean diameter of rubber fume (63-73 nm) was (larger than diesel exhaust [12 nm] and outdoor dust [50 nm]). The concentration of carbon disulfide, carbon monoxide and styrene were lower than the limit of detection. Five SCD cases were exposed to shift work and overworking. Most of the cases had several non-occupational factors such as hypertension, overweight and smoking. Conclusion: The diameter of rubber fume was larger than outdoor and the diesel exhaust, the most well known particulate having a causal relationship with cardiovascular disease. The possibility of a causal relation between UFPs of rubber fume and SCD was not supported in this study. However, it is necessary to continue studying the relationship between large sized UFPs and SCD.

A Study on the Estimation of Autogenous Shrinkage of High Strength Mortar incorporating Mineral Admixture by Equivalent Age Method (등가재령 방법에 의한 혼화재 치환 고강도 시멘트 모르타르의 자기수축 해석에 관한 연구)

  • Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.1
    • /
    • pp.110-117
    • /
    • 2014
  • The objective of this study is to investigate an effect of curing temperature on autogenous shrinkage of high strength cement mortar with 0.15 of W/B incorporating fly ash and silica fume in terms of equivalent age. The contents of fly ash and silica fume are varied from 10% to 30%. Non linear regression model applying equivalent age was used to estimate the autogenous shrinkage evolution. To obtain apparent activation energy($E_a$), setting time method by Pinto and existing method were calculated and compared respectively. Test results showed that use of silica fume increased autogenous shrinkage while use of fly ash decreased it. It was also found that poor agreements were obtained when $E_a$ by setting time was applied. But, application of existing $E_a$ resulted in a good agreement between calculated autogenous shrinkage and measured one.

Sonication in the Analysis of Hexavalent Chromium in Welding Fume (초음파 전처리에 의한 용접 흄 중 6가 크롬의 분석)

  • Yoon, Chung-Sik;Paik, Nam-Won;Kim, Jeong-Han;Park, Dong-Uk;Choi, Sang-Jun;Kim, Shin-Bum;Chae, Hyun-Byung
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.447-459
    • /
    • 1999
  • A study was conducted to compare three analytical methods for determination of hexavalent chromium in the welding fume. Precision and accuracy arc documented for colorimetric, ion chromatographic, and inductively coupled plasma-optical emission spectroscopic method. Evidence is presented that welding fume can affect the oxidation of trivalent chromium. A simple sonication extraction method, proposed in this study, instead of hot alkaline extraction has the advantage of minimizing the potential for chromium oxidation.

  • PDF

Fire Resistance Performance Test of High Strength Concrete by Type of Mineral Admixture (혼화재 종류에 따른 고강도 콘크리트의 내화성능 평가)

  • Kwon, Ki-Seok;Ryu, Dong-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.6
    • /
    • pp.597-605
    • /
    • 2015
  • The method of concrete mix design used in this study aims to achieve the identical specified design strength, applying different types and replacement ratio of mineral admixtures and afterwards, fire tests were conducted using the standard time-temperature curve specified in the ASTM E119 to identify the influences of the types of mineral admixtures on the fire resistance performance of high strength concrete(HSC). The least spalling was observed in the test specimen containing blast furnace slag as a partial replacement of cement, while the most significant spalling phenomena were observed in the blast furnace slag test specimen that silica-fume was added in. In particular, the reasonable volume of spalling was observed when solely replaced by silica fume. However, the influence of the cement replacement by silica fume and blast furnace slag on the increases of spalling can be explained through blocked pores by the fine particles of silica fume, leading to decreases in permeability.

A Model-Analysis for Removal of Fire Fumes in a Road Tunnel during a Fire Disaster (도로터널내 화재 발생시 매연 제거를 위한 모델 해석)

  • 윤성욱;이희근
    • Tunnel and Underground Space
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 1997
  • In case of a fire outbreak in a uni-directional road tunnel, the flow of traffic immediately behind the fire disaster will be stalled all the way back to the entrance of the tunnel. Furthermore, when the vehicle passengers try to flee away from the fire toward the entrance of the tunnel, the extremely hot fume that propagates in the same direction will be fatal to the multitudes evacuating, but may also cause damage to the ventilation equipments and the vehicles, compounding the evacuation process. This paper will present the 3-dimensional modelling analysis of the preventive measures of such a fume propagation in the same direction as the evacuating passengers. For the analysis, the fire hazard was assumed to be a perfect combustion of methane gas injected through the 1 m X 2 m nozzle in the middle of the tunnel, and the product of $CO_2$ as the indicator of the fume propagation. From the research results, when the fire hazard occurred in middle of the 400 m road tunnel, the air density decreased around the fire point, and the maximum temperatures were 996 K and 499 K at 210 m and 350 m locations, respectively, 60 seconds after fire disaster occurred, when the fumes were driven out only towards the exit-direction of the tunnel. By tracing the increase of $CO_2$ level over 1% mole fraction, the minimum longitudinal ventilation velocity was found to be 2.40 m/sec. Furthermore, through Analysis of the temperature distribution graphs, and observation of the cross-sectional distribution of $CO_2$ over 1% mole fraction, it was found that the fume did not mix with the air, but rather moved far in a laminar flow towards exit of the tunnel.

  • PDF