• 제목/요약/키워드: Full scale experiment

검색결과 237건 처리시간 0.027초

전력용변압기에서 UHF 부분방전 신호의 전파 특성 (Propagation Characteristics of Ultra High Frequency Partial Discharge Signals in Power Transformer)

  • 윤진열;한기선;주형준;구선근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.798-803
    • /
    • 2010
  • This paper describes the characteristics of electromagnetic wave propagation in power transformer. A transformer which is similar to 154 kV single phase on-site transformer unit was provided for the purpose of the experiment. The 12 dielectric windows on the transformer enclosure to install UHF (ultra high frequency) sensors and the full scale mock ups of winding and the core were also equipped in the transformer. Every sensors to be installed to the transformer was tested and verified whether they show same characteristics or not before the experiment. A discharge gap which was used as a PD (partial discharge) source moved to several necessary locations in the transformer to simulate dielectric defects. Propagation times of electromagnetic wave signal from PD source to sensors decided by the routes of both reflection phenomenon and diffraction phenomenon were compared each other. The experimental results showed propagation route of the PD signal makes an effect on the frequency spectrum of front part of the signal and the magnitude of the signal and propagation time of the signal when the signal is captured on the sensor.

데크플레이트의 휨 강도에 관한 기준 비교 연구 (An Investigation into differences between codes for the Moment Strength of Deck Plates)

  • 신태송
    • 한국강구조학회 논문집
    • /
    • 제15권1호
    • /
    • pp.25-31
    • /
    • 2003
  • 본 연구는 데크플레이트의 모멘트 강도에 관한 실험적, 이론적 연구를 수행하였다. 실물크기의 14개 모멘트 실험을 행하였으며, 가력부의 국부좌굴을 방지하기 위해 1/4지점 집중하중을 가력하였다. 기준식들 간의 차이점을 이론적으로 비교분석하였다. 또한 미국 AISI, 유럽 EC3, 한국 기준과 실험값을 비교 평가하였다. 파괴모드는 보 중앙부의 국부좌굴 및 중간가력부의 국부좌굴에 의하여 형성되어 최대내력에 도달하였다. 인장측이 먼저 항복하는 경우 소성능력이 인장측에서 발휘되어 내력이 증대하였다. 설험결과는 인장측 부분 소성화를 고려한 EC 기준과 가장 잘 일치하였다. EC3 부록Z에 의한 통계학적 평가로부터 EC3 기준식이 목표로 하는 $^{\circ}{_M}=1.1$ 이내로 그 적용성이 만족되었다. AISI와 KS 기준에서도 소성화 개념을 추가한다면, 이론해석이 보다 더 개선될 것이다.

하수고도처리에서 층상이중수화물을 이용한 인산 이온교환 특성 (Characteristics of Ion Exchange of Phosphate using Layered Double Hydroxides in Advanced Wastewater Treatment)

  • 송지현;신승규;이상협;박기영
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.991-995
    • /
    • 2006
  • The layered double hydroxide with the insertion of chloride ions (LDH-Cl), which was synthesized by the co-precipitation method, was applied to investigate the fundamental aspects of the absorptive agent for phosphate removal from wastewater. The adsorption capacity was best described by the Langmuir-FreundIich isotherm, and the estimated isotherm parameters indicate that the LDH-CI capacity for the phosphate removal is much higher than that observed using a natural adsorbent material such iron oxide tailing. The kinetic experiment also showed that the LDH-Cl adsorption reaction rapidly at the adsorptive rate of 0.55 mg-P/g-LDH/min, implying that this adsorbent can be of use in the full-scale applications. The pH had a minimal effect on the LDH adsorption capacity in the range of 5 to 11, although the capacity dropped at the low pHs because of the change in LDH surface properties. Furthermore, other anions such as $Cl^-$ and $NO_3{^-}$ commonly found in the wastewater streams insignificantly affected the phosphate removal efficiencies, while $HCO_3{^-}$ ions had a negative effect on the LDH adsorption capacity due to its high selectivity. The phosphate removal experiment using the actual secondary effluent from a wastewater treatment plant showed the similar decrease in adsorption capacity, indicating that the bicarbonate ions in the wastewater were competing with phosphate for the adsorptive site in the surface of the LDH-Cl. Overall, the synthetic adsorbent material, LDH-Cl, can be a feasible alternative over other conventional chemical agents, since the LDH-Cl exhibits the high phosphate removal capacity with the low sensitivity to other environmental conditions.

$CO_2$ 소화설비 방사시 정보저장장치의 저온손상에 관한 연구 (An Experimental Study on the Damage of the Data Process Equipment When $CO_2$ is Discharged)

  • 이수경;김종훈;김영진;최종운
    • 한국화재소방학회논문지
    • /
    • 제13권3호
    • /
    • pp.19-26
    • /
    • 1999
  • 이산화탄소 소화설비는 가스계 소화설비 중 비용의 저렴함과 작동후의 청결함, 그리고 절연성등의 특성으로 인하여 통신기기설, 전산실, 전기실 등에 많이 사용되고 있다. 이산화탄소는 저장시 액체이다가 방출과 동시에 가스상태로 기화하는데 이때 온도가 급격히 내려간다. 이러한 냉각효과에 의하여 반도체장비나 정보저장장치에 손상을 줄 수 있다. 본 연구는 이산화탄소 방사시 구획내부의 온도분포와 손상정도를 규명하여 차후 연구의 기초자료를 제공하고 $CO_2$소화설비 설계나 관련규정의 정비에 도움이 되고자 시행했다. $CO_2$ 소화설비 방사 시 노즐부분의 순간방출온도는 $-82.53^{\circ}C$까지 내려갔다. 소화약제가 모두 방사되는 1분경의 실내평균온도는 $-40^{\circ}C$이며 이는 충분히 정보저장 장치류에 피해를 입힐 수 있는 온도이다. 플로피 디스켓을 설치하고 실험한 결과 70%의 고장율을 보였다. 컴퓨터를 넣고 실제 화재를 일으켜 실험한 결과, 특별한 고장이 없었으나, 작동으로 인한 내부의 열과의 온도차이에 의하여 수증기가 응결되고 녹아 흐르는 현상을 보여 Water Damage의 발생가능성을 발견할 수 있었다. 또한 저온지속시간(-5$^{\circ}C$기준)이 각 시나리오에서 평균 5분이상 나타났으며, 만약 실내의 단열과 밀폐조건이 더욱 좋은 경우라면 더 장시간 지속될 수 있다.

  • PDF

실험 계획법을 이용한 점착방지막용 플라즈마 증착 공정변수의 최적화 연구 (Optimizing the Plasma Deposition Process Parameters of Antistiction Layers Using a DOE (Design of Experiment))

  • 차남구;박창화;조민수;박진구;정준호;이응숙
    • 한국재료학회지
    • /
    • 제15권11호
    • /
    • pp.705-710
    • /
    • 2005
  • NIL (nanoimprint lithography) technique has demonstrated a high potential for wafer size definition of nanometer as well as micrometer size patterns. During the replication process by NIL, the stiction between the stamp and the polymer is one of major problems. This stiction problem is moi·e important in small sized patterns. An antistiction layer prevents this stiction ana insures a clean demolding process. In this paper, we were using a TCP (transfer coupled plasma) equipment and $C_4F_8$ as a precursor to make a Teflon-like antistiction layer. This antistiction layer was deposited on a 6 inch silicon wafer to have nanometer scale thicknesses. The thickness of deposited antistiction layer was measured by ellipsometry. To optimize the process factor such as table height (TH), substrate temperature (ST), working pressure (WP) and plasma power (PP), we were using a design of experimental (DOE) method. The table of full factorial arrays was set by the 4 factors and 2 levels. Using this table, experiments were organized to achieve 2 responses such as deposition rate and non-uniformity. It was investigated that the main effects and interaction effects between parameters. Deposition rate was in proportion to table height, working pressure and plasma power. Non-uniformity was in proportion to substrate temperature and working pressure. Using a response optimization, we were able to get the optimized deposition condition at desired deposition rate and an experimental deposition rate showed similar results.

Identification of acrosswind load effects on tall slender structures

  • Jae-Seung Hwang;Dae-Kun Kwon;Jungtae Noh;Ahsan Kareem
    • Wind and Structures
    • /
    • 제36권4호
    • /
    • pp.221-236
    • /
    • 2023
  • The lateral component of turbulence and the vortices shed in the wake of a structure result in introducing dynamic wind load in the acrosswind direction and the resulting level of motion is typically larger than the corresponding alongwind motion for a dynamically sensitive structure. The underlying source mechanisms of the acrosswind load may be classified into motion-induced, buffeting, and Strouhal components. This study proposes a frequency domain framework to decompose the overall load into these components based on output-only measurements from wind tunnel experiments or full-scale measurements. First, the total acrosswind load is identified based on measured acceleration response by solving the inverse problem using the Kalman filter technique. The decomposition of the combined load is then performed by modeling each load component in terms of a Bayesian filtering scheme. More specifically, the decomposition and the estimation of the model parameters are accomplished using the unscented Kalman filter in the frequency domain. An aeroelastic wind tunnel experiment involving a tall circular cylinder was carried out for the validation of the proposed framework. The contribution of each load component to the acrosswind response is assessed by re-analyzing the system with the decomposed components. Through comparison of the measured and the re-analyzed response, it is demonstrated that the proposed framework effectively decomposes the total acrosswind load into components and sheds light on the overall underlying mechanism of the acrosswind load and attendant structural response. The delineation of these load components and their subsequent modeling and control may become increasingly important as tall slender buildings of the prismatic cross-section that are highly sensitive to the acrosswind load effects are increasingly being built in major metropolises.

하수처리장의 고도처리 upgrading 설계와 공정 최적화를 위한 다변량 통계분석 (Design of a Wastewater Treatment Plant Upgrading to Advanced Nutrient Removal Treatment Using Modeling Methodology and Multivariate Statistical Analysis for Process Optimization)

  • 김민정;김민한;김용수;유창규
    • Korean Chemical Engineering Research
    • /
    • 제48권5호
    • /
    • pp.589-597
    • /
    • 2010
  • 하수처리 시스템에서의 생물학적 영양염류 기준이 강화됨에 따라, 표준활성슬러지공법으로 운전 중인 하수처리장의 고도처리 공법으로의 개보수 필요성이 증가하고 있다. 그러나 실제 하수처리 시스템에서의 다양한 유입조건 및 운전조건의 복잡한 반응 구성으로 인해 실험을 통하여 개보수된 고도처리공법의 최적조건을 찾는 것은 쉽지 않은 일이며, 이는 많은 시간과 비용을 소모하여 비효율적이다. 따라서 본 연구에서는 활성슬러지공정모델(ASMs)을 기반으로 한 하수처리장의 모델링 및 시뮬레이션 기법을 통하여 하수처리장의 고도처리공법으로의 upgrading 설계를 수행하며, 이를 통계적이며 체계적으로 접근하기 위해 반응표면분석법(Response surface method)을 통한 고도처리공법의 설계 최적화를 수행하였다. 또한 실규모 하수처리장에서의 운전 최적화를 위해서는 하수처리의 동력학적 매개변수에 대한 정확한 분석이 수행되어야 한다. 본 연구에서는 다변량 통계분석 기법인 부분최소승자법(PLS)을 통하여 하수처리 시스템의 동력학적 매개변수 간의 상관관계를 파악하며, 고도처리공법 하수처리장의 운전 결과에 가장 큰 영향을 미치는 매개변수를 도출하였다. 본 연구를 통해 하수처리장의 고도처리공법 upgrading 설계 및 운전 최적화를 위한 방법론을 제시하였으며, 이를 통하여 설계시간 및 경비 절감 등 고도처리공법으로의 고효율적인 개보수가 가능할 것으로 예상된다.

한정연성 철근콘크리트 교각의 유사동적 실험에 의한 내진 성능 평가 (Seismic Performance Evaluation of RC Bridge Piers with Limited Ductility by the Pseudo-Dynamic Test)

  • 정영수;박창규;박진영
    • 콘크리트학회논문집
    • /
    • 제15권5호
    • /
    • pp.705-714
    • /
    • 2003
  • 우리나라는 선진 외국에 비하여 늦은 1992년에 도로교 표준시방에 내진설계편이 도입되었다. 따라서, 1992년 이전에 설계된 교각들은 내진 설계가 되어있지 않음은 물론 시공편의상 소성힌지 구간에 주철근이 겹침이음 시공되어 현재에도 사용되고 있다. 또한, 현행 내진규정도 강진지역의 설계규정을 도입함으로써 중 약진 지역에 속하는 우리의 현실에 맞지 않아 현장에서 복잡한 철근배근을 요구함으로 시공성 및 경제성이 많이 떨어지고 있는 실정이다. 본 연구에서는 1992년 이전에 비내진 설계/시공되어 공용중인 원형 교각을 조사하여, 주철근이 겹침이음된 기준실험체(주철근비 1.01%, 심부구속철근비 0.13%) 1개를 실물크기와 유사하도록 직경 1.2m, 높이 4.8m로 제작하였으며, 또한 중 약진 지역에 속하는 우리나라의 실정을 감안하여 심부구속철근비를 비내진 규정의의 2.3배 현행 내진 설계규정의 0.32배에 해당하는 0.30%의 한정연성실험체 3개를 제작하여 유사동적 실험을 통하여 내진 연성도 평가를 하였다. 실험결과 비내진 실험체는 요구변위연성도 5를 만족시키지 못하였고, 한정연성 실험체의 경우는 현행 내진규정의 요구 변위연성도 5를 만족하는 것으로 나타났다.

Full-Scale SBR 공법을 이용한 처리특성 (Treatment Characteristics Using Full-Scale SBR System)

  • 추태호;이용두;조용현
    • 한국콘텐츠학회논문지
    • /
    • 제6권10호
    • /
    • pp.34-40
    • /
    • 2006
  • 본 연구에서 연속회분식반응기(SBR)를 이용한 유기물질과 영양염류(N, P)처리가 수행되었다. 이 연구 결과들을 요약하면 다음과 같다. BOD는 $19.6{\sim}40.0mg/L$의 범위로 유입되고, 처리수는 $3.0{\sim}14.8mg/L$로 실험기간의 경과에 따라 점차 안정적으로 처리되었다. 이때의 제거율은 $47.9{\sim}88.4%$로 평균 80.0%로 안정적인 제거율을 보였다. 그리고 COD는 $12.2{\sim}32.0mg/L$의 범위로 유입되었으며, 처리수는 $3.3{\sim}18.6mg/L$로 제거율은 $19.2{\sim}78.6%$로 평균 57.3%의 제거율을 보였다. 하지만 79일 이후의 평균 COD 제거율은 70.2%로 안정적인 제거율은 보였다. T-N의 경우 유입농도는 $7.53{\sim}14.99mg/L$, 처리수는 초기 79일까지는 평균 6.59mg/L로 제거율이 평균 40.3%로 낮았지만 시스템이 정상화된 80일 이후는 평균 4.44mg/L로 처리되어 그 제거율이 56.4%로 나타났다. 또한 T-P의 경우는 유입수의 농도는 $0.77{\sim}1.91mg/L$, 처리수는 $0.26{\sim}1.53mg/L$으로 제거율이 $5.3{\sim}71.7%$로 상당히 큰 변화를 보였으며, 평균제거율은 42.6%로 나타났다. 이는 MLSS 증가를 위해 슬러지 인발을 하지 않았기 때문으로 판단된다.

  • PDF

수치해석을 이용한 육각 낙석방지망의 성능 평가 (Performance Estimation of Hexagonal Rockfall Protection Net by Numerical Analysis)

  • 오세욱;박수범;권영철
    • 한국지반환경공학회 논문집
    • /
    • 제15권11호
    • /
    • pp.53-59
    • /
    • 2014
  • 낙석방지망에 대한 기존 연구 결과에 의하면 종래의 낙석방지망에서 발생되는 대표적인 문제점으로 이완성이 없는 횡방향 와이어로프에 의해 발생되는 낙석 중량의 누적현상, 지반과 낙석방지망의 결합지점 부족으로 인한 인발지지력 부족, 낙석의 과도한 충격으로 인한 철망의 빈번한 파손, 낙석방지망의 유지관리 시 철망의 재사용의 어려움 등이 보고되고 있다. 선행 연구를 통해 실내에서의 인장력과 현장실험이 실시되어 새로운 낙석방지망의 효과를 검증한 바 있다. 선행연구에 이어 본 연구에서는 기존의 사각낙석방지망과 비교하여 충격 완화형 육각 낙석방지망의 전체적인 구조적 안정성과 성능을 수치해석적 방법을 통해 점검하는 것에 그 목적이 있으며, 이를 충분히 검토하고 결과를 얻을 수 있도록 수치해석 프로그램이 설정되었다. 수치해석 결과를 종합해볼 때 동일한 단일 셀 간격 뿐만 아니라 동일한 면적비로 비교하더라도 육각 낙석방지망이 사각 낙석방지망에 비해 하중분배 효과가 우수한 것으로 나타났으며, 육각 낙석방지망은 낙석하중이 작용할 경우 이를 효율적으로 분산시킴으로써 과도한 하중 집중이 발생하는 것을 피할 수 있어 장기적인 안정성 확보에 유리할 것으로 판단된다.