• Title/Summary/Keyword: Full resonance

Search Result 250, Processing Time 0.029 seconds

A Hybrid DC/DC Converter for EV OBCs Using Full-bridge and Resonant Converters with a Single Transformer

  • Hassan, Najam ul;Kim, Yoon-Jae;Han, Byung-Moon;Lee, Jun-Young
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.11-19
    • /
    • 2017
  • This paper proposes a dc/dc converter for electric vehicle onboard chargers using a secondary resonant tank. To attain soft switching characteristics, such as zero voltage switching, magnetizing inductance has been used at the primary side of the transformer. The leakage inductance of the transformer is used as a resonant inductor on the secondary side to avoid the use of a separate inductor as resonance. The proposed converter is applicable for a wide load range. A 6.6KW prototype has been implemented for a wide range of load variations (250V, 330V, 360V, and 413V). A maximum efficiency of 97.4% is achieved at 413V.

Improvement and Operation of a Helicopter Tail-Fan Performance Test System (헬리콥터 테일팬 시험장치 개조 및 운용)

  • Lee, Je-Dong;Song, Keun-Woong;Kang, Hee-Jung;Sim, Jung-Wook;Kim, Seung-Bum
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.41-44
    • /
    • 2005
  • This paper described improvement and operation of a 'Tail-Fan' anti-torque performance test system KARI (Korea Aerospace Research Institute) developed a 'Tail-Fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the Tail-Fan. The test-rig was improved for full rotating test in 4300rpm(100%). Machinery and hydraulic parts ware changed to reduce vibration and to increase safety. To find the operation rotating speed for the performance test, vibration test were carried out rising accelerometers on tail gear box. The performance test conditions of the Tail-Fan to avoid a resonance were found from vibration test results. The Tail-Fan operation tests were performed safely frier to carry out performance test.

  • PDF

Reduction of Booming Noise Using Damper Clutch Disk on the Drive Shaft of Commercial Small Truck (상업용 소형 트럭의 구동축에서 댐퍼 클러치 디스크를 이용한 부밍 소음 저감)

  • Kim, Yong Dae;Choi, Byungjae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.6
    • /
    • pp.377-383
    • /
    • 2015
  • Torsion mode or bending mode of drive-line for rear-wheel drive vehicle exists in low frequency band. If resonance exists there between natural mode of driveline and powertrain excitation force, drive-line will manifest excessive vibration response. Also, the vibration response can be transmitted to vehicle body and can induce booming noise. A vehicle in this study exhibits a booming noise problem under specific transmission gear condition. To draw performance improvement plan, finite element analysis technique was used. Modification was evaluated qualitatively and priorities were derived. Finally, effectiveness of best modification was verified through test and full vehicle FE analysis.

Arthroscopic Treatment of Isolated Teres Minor Tendon Tear: A Case Report

  • Lee, Se-Won;Park, Sang-Eun;Park, Min-Gyu;Ji, Jong-Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.159-161
    • /
    • 2015
  • Arthroscopic repair of an isolated teres minor tendon tear without associated shoulder joint pathology has not been reported in the literature. We report on a case of isolated teres minor tendon tear after trauma. The patient complained of severe shoulder pain and progressive limited range of motion 4 months after the injury. Magnetic resonance imaging showed a full-thickness tear of the teres minor tendon at its musculotendinous junction and arthroscopic repair was performed. At 2 years follow-up, satisfactory clinical and radiological outcomes were observed with return to pre-injury level. Here, the authors report this case and provide a review of literature.

Half-Bridge Resonant Converter with Coreless Isolation Transformer (공심 절연변압기를 구비한 반브릿지 공진형 컨버터)

  • Heo, Joon;Jeon, Seong-Jeub
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.636-642
    • /
    • 2017
  • Recently, new power devices, SiC and GaN FETs, are commercialized. They are expected to change power electronics environments. They will raise operating frequencies of power electronic equipments. Accordingly, design method will be changed greatly. In this paper, an 1 MHz resonant converter with fully compensated coreless isolation transformer is proposed, where the primary voltage is proportional to the secondary current and the primary current to the secondary voltage. 30 W prototype is constructed and tested, and its usefulness is verified.

The Design and Fabrication of an Electronic Ballast for High Intensity Short-Arc Lamps (고휘도 Short-Arc 램프용 전자식 안정기 설계 및 제작)

  • Kim, Il-Kwon;Park, Dae-Won;Lee, Sung-Geun;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.304-309
    • /
    • 2005
  • This paper presents an electronic ballast using a step down converter, a low frequency inverter for high intensity short-arc discharge lamp. The proposed ballast is composed of a full-wave rectifier, a step down converter operated as a current source with power regulation and a low frequency inverter with external ignition circuit. The ignition circuit generates high voltage pulse of $3{\sim}5[kV]$ peak, 130[Hz] periodically. Moreover, it is able to reignite at regular intervals by protective circuit. As experimental results on the test, acoustic resonance phenomenon is eliminated by operating the low frequency square wave voltage and current. Lamp voltage, current and consumption power are measured 123.8[V], 8.1[A] and 1,002[W], respectively. It was confirmed that the designed ballast operate the lamp with a constant power.

  • PDF

Design of a Speed Controller for 2-Mass System Based on Neural Network and Observer (신경 회로망과 관측기에 기반한 2-mass 시스템에서의 속도 제어기 설계)

  • 현대성;박정일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.361-361
    • /
    • 2000
  • In the 2-mass system with flexible shaft, a torsional vibration is often generated because of the elastic elements in torque transmission as the newly required speed response which is very close to the primary resonant frequency. This vibration makes it difficult to achieve quick responses of speed and disturbance rejection. In this paper, 2-mass system is designed by using pole placement based on optimal control theory fur fast speed response and torsional vibration elimination and using neural network for disturbance rejection in particular. The simulation results show that the proposed controller based on neural network and full state feedback controller has better performance than 려ll state feedback controller, especially fur disturbance rejection.

  • PDF

Experimental Verification of Transverse Electric Mode Controlled Vacuum Chamber of PLS-II Storage Ring

  • Ju, Yeong-Do;Ha, Tae-Gyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.229-229
    • /
    • 2012
  • It is significant issue to control the unwanted transverse electric (TE) modes in the vacuum chamber for preventing the position reading noise from the beam position monitor (BPM) of storage ring. We introduce shunt structure to control the frequency distribution of TE resonance modes excited in the vacuum chambers of the Pohang Light Source II (PLS-II). The design of shunt structure is performed using the full three dimensional finite-difference time-domain (FDTD) simulation. It is verified that the sympton of the BPM noise is not oberved up to the beam current of 190 mA in the commmissioning of PLS-II.

  • PDF

Plain Chest X-ray Diagnosis of Respiratory Disease (호흡기 질환에서 단순흉부 X-선 진단)

  • Kim, Sang-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.4
    • /
    • pp.353-356
    • /
    • 1993
  • Advent of new imaging modalities such as computed tomography, magnetic resonance imaging and ultrasound contributed greately to the specific imaging diagnosis. However plain chest X-ray is still most prequently used for imaging diagnosis of respiratory disease in clinical pratic and it is important to make a good quality of X-ray film and good interpretation. The optimal chest X-ray should be taken with full inspiration without rotation and motion and the exposure is at the level of barely demonstrable thoracic vertebral disc space. It is recommended that higk KVP technique for detection of lesions which is overlaped by mediastinum, heart and rib cage. It is better to examine chest X-ray film start at some distance(6-8 feet) and closer to the film later on and the reader should not read a film in fatigue condition. The reading room should be quiet and relately dark illumination. It is important, to make a good X-ray film and good interpretation to reduce the observer error.

  • PDF

A Study on the Optimal Design of 5 kW Plasma Discharger (5kW급 플라즈마 방전장치 설계 최적화의 관한 연구)

  • Noh, Hyun-Kyu;Shin, Chul-Jun;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2016
  • This paper presents a study on the design optimization of a 5 kW plasma discharger for driving plasma reactor. The proposed study is composed of a high-frequency inverter based on the full-bridge circuit using soft switching techniques for high-frequency switching. The switching frequency in the operating region is the area of 130-200 kHz. By applying the LC resonance technique and a variable switching frequency, control technique is designed to be stable under changes in the load characteristics of the plasma reactor. This paper presents a quantitative analysis technique for design optimization. Experiments are performed according to load characteristic variations depending on the vacuum of the plasma reactor. This paper has verified the topology and design method for the 5 kW plasma discharger design.