• 제목/요약/키워드: Full Load Operating Condition

검색결과 29건 처리시간 0.023초

압축기출구에 공기분사가 터보과급 디젤기관의 성능에 미치는 영향에 관한 연구 (A Study on the Effects of Injected Air into the Compressor Exit for the Performances of a Turbocharged Diesel Engine)

  • 최낙정;이창식
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.796-805
    • /
    • 1995
  • For the purpose of improving performances of a turbocharged diesel engine at low speed, this study investigates the effects of the injected air for the performances and flow characteristics in the intake and exhaust pipes by using the computer simulation with test bed. In the theoretical analysis, the whole flow system, including engine cylinders and intake and exhaust pipes, is calculated numerically by the method of filling and emptying. From the results of this study, the following conclusions may be summarized. Increasing injected air pressure into the pipe of compressor exit brings about the improvement in a performance and flow characteristics of intake and exhaust pipes under full load operating conditions at 1000 rpm of the engine speed, but shows trends of the inferior performances under no load operating conditions at 2000 rpm of the engine speed.

정상운항 상태에서 쇄빙선박에 작용하는 설계 빙하중 추정 (Prediction of Design Ice Load on Icebreaking Vessels under Normal Operating Conditions)

  • 최경식;정성엽;남종호
    • 대한조선학회논문집
    • /
    • 제46권6호
    • /
    • pp.603-610
    • /
    • 2009
  • Ice load is one of the important design parameters for the construction of icebreaking vessels. In this paper, the design ice load prediction for the icebreaking vessels under normal operating condition in ice-covered sea is discussed. The ice loads under normal operating condition are expected from sea trials in moderate ice conditions. In this sense the extreme ice loads during heavy ramming or accidental collision are not considered. Current study describes the global ice load on the hull of the icebreaking vessels. Available ice load data from full-scale sea trials are collected and analyzed according to various ship-ice interaction parameters including displacement, stem angle, speed of a ship and flexural strength and thickness of sea ice. The ice load prediction formula is compared with the collected full-scale sea trials data and it shows a good agreement.

Design Guidelines for a Capacitive Wireless Power Transfer System with Input/Output Matching Transformers

  • Choi, Sung-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1656-1663
    • /
    • 2016
  • A capacitive wireless power transfer (C-WPT) system uses an electric field to transmit power through a physical isolation barrier which forms a pair of ac link capacitors between the metal plates. However, the physical dimension and low dielectric constant of the interface medium severely limit the effective link capacitance to a level comparable to the main switch output capacitance of the transmitting circuit, which thus narrows the soft-switching range in the light load condition. Moreover, by fundamental limit analysis, it can be proved that such a low link capacitance increases operating frequency and capacitor voltage stress in the full load condition. In order to handle these problems, this paper investigates optimal design of double matching transformer networks for C-WPT. Using mathematical analysis with fundamental harmonic approximation, a design guideline is presented to avoid unnecessarily high frequency operation, to suppress the voltage stress on the link capacitors, and to achieve wide ZVS range even with low link capacitance. Simulation and hardware implementation are performed on a 5-W prototype system equipped with a 256-pF link capacitance and a 200-pF switch output capacitance. Results show that the proposed scheme ensures zero-voltage-switching from full load to 10% load, and the switching frequency and the link capacitor voltage stress are kept below 250 kHz and 452 V, respectively, in the full load condition.

함정용 탐색레이더 안테나의 구동 토크 분석 및 감쇄에 대한 연구 (Study on Analysis of Driving Torque and Reduction for Naval Surveillance Radar Antenna)

  • 김승우;양윤석
    • 한국군사과학기술학회지
    • /
    • 제12권3호
    • /
    • pp.388-395
    • /
    • 2009
  • Surveillance Radar System for naval vessels is a primary core sensor for command and fire control, and provides CFCS(Command and Fire Control System) information for 3-D surveillance and fire control. It's composed of Antenna, Transmitter/Receiver, Signal Processor, and Air drier, which are installed on and under deck. They should be designed and produced in order to endure at any operating circumstances. This paper analyzes load of a driving part for driving the antenna considering factors under external operating circumstances, and proposes a condition of load for maintaining fixed RPM through analyzing internal load of the driving part, and how to reduce the load to meet the condition. This paper is verified through experimental studies.

쇄빙연구선 ARAON호의 남극해 쇄빙운항 중 계측된 스트레인게이지 데이터 분석 (Analysis of Strain Gauge Data Onboard the IBRV ARAON during Icebreaking Voyage in the Antarctic Sea Ice)

  • 천은지;최경식;김호연;이탁기
    • 대한조선학회논문집
    • /
    • 제51권6호
    • /
    • pp.489-494
    • /
    • 2014
  • Estimation of correct ice load under various operating conditions is important during the design and the operation stages of an icebreaker. Normal operating conditions are expected from the official field ice trials and also from general ice transit action. In this paper ice load for the Korean icebreaking research vessel, ARAON, under normal operating condition, is discussed. Published ice load data from full-scale sea trials of six icebreakers were analysed to derive an empirical ice load prediction formula. The IBRV ARAON had sea ice trials during 2010 and 2012 summer season. Strain gauge signal were recorded during her icebreaking voyage and the measured strain data were converted to the equivalent hull stress values. The effect of ARAON's speed in ice and the hull stresses are investigated. By comparing the empirical formula and ice load calculation based von measured data, it is recommended to use the empirical ice load estimation formula for the initial design stage.

5MW급 발전용 가스터빈 엔진의 작동 특성 (Operating Characteristics of 5MW Class Gas Turbine Engine for Power Generation)

  • 박준철;홍성진;;류제욱
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.331-334
    • /
    • 2010
  • 두산중공업(주)에서 개발 중인 발전용 가스터빈 DGT-5 엔진의 작동 특성을 평가하였다. 다양한 연료 스케쥴과 여러 가지 조합의 bleed valve 개폐 제어에 대한 영향을 분석하기 위한 시험을 통해 시동 특성을 개선하였고, 시동부터 부하운전 전체 작동 영역에서 압축기에서의 불안정 현상 없이 엔진이 안정적으로 작동됨을 확인하였다. 순간적인 부하 변동과 load rejection에 대한 엔진의 동적 거동 분석을 통해 실제 계통 병입 조건에서 급격한 부하변동 시 엔진이 안정적으로 제어될 수 있음을 확인하였다.

  • PDF

200kW 급 마이크로 가스터빈의 운전특성 분석 (Analysis of Operating Characteristics of 200kW Class Micro Gas Turbine)

  • 김정호;강도원;김동섭
    • 대한기계학회논문집B
    • /
    • 제37권11호
    • /
    • pp.1015-1022
    • /
    • 2013
  • 본 연구에서는 현재 개발중인 200kW 급 마이크로 가스터빈의 운전 특성을 모사하였다. 세부적인 성능 데이터를 이용하여 부분부하 제어방식(터빈 입구온도 제어방식(constant TIT control)과 터빈 출구온도 제어방식(constant TET control))과 외기온도에 따른 성능 및 작동특성을 분석하였다. 넓은 운전 범위에 대하여 압축기 서지마진과 터빈 입출구 온도 같은 작동 파라미터의 민감도를 단위 연료량 변화에 따라 예측하였다. 정상상태 계산으로 부분부하 변동 시 최대서지마진의 감소에 대한 정보를 민감도 분석을 통해 알 수 있다.

향상된 직렬 부하 공진형 컨버터 토폴로지를 이용한 10kW DC/DC 컨버터 (10kW DC/DC Converter using Modified Series Loaded Resonant Topology)

  • 안석호;공지웅;장성록;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.215-216
    • /
    • 2012
  • This paper proposes a modified converter topology from the existing loaded resonant converter and describe the development of 10kW(50~500V, 0~ 50A) DC/DC Converter using the proposed topology. The suggested converter, which revised the topology of the converter operating on the CCM(Continuous Conduction Mode) (above resonance), has the advantage of enhancing the efficiency of rated load operation by rapidly increasing the primary side resonant current and by improving the resonance current in a trapezoid shape. The proposed topology is described with analysis of operating mode and designed using PSpice simulation and the points on design to consider when implementing the topology are described. It is verified that the advantages of the proposed topology centered on rated load are effectively highlighted. Experimental results carried out at different condition and its results shows 98.5% efficiency at full load condition.

  • PDF

A Novel Soft-Switching Full-Bridge PWM Converter with an Energy Recovery Circuit

  • Lee, Dong-Young;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.809-821
    • /
    • 2009
  • This paper proposes a new phase-shift full-bridge DC-DC converter by applying energy recovery circuits to a conventional full-bridge DC-DC converter in plasma display panel applications. The converter can achieve soft-switching in main-switches by an extra auxiliary resonant network even with the wide operating condition of both output load and input voltage. The un-coupled design guidelines to the main bridge-leg component parameters for soft-switching operation contribute to conduction loss reduction in the transformer primary side leading to efficiency improvement. The auxiliary switches in the resonant network also operate in zero-current switching. This paper analyzes the operation modes of the proposed scheme and presents the key design guidelines through steady state analysis. Also, the paper verifies the validity of the circuits by hardware experiments with a 1kW DC/DC converter prototype.

하이포이드 기어의 소음원인규명을 위한 디플렉션 테스트와 전달에러 측정에 대한 연구 (Identify Hypoid gear whine noise for Deflection test and Transmission error measurement)

  • 최병재;오재응;박상길
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1040-1047
    • /
    • 2008
  • Hypoid gears are widely used in rear drive and 4WD vehicle axles. Investigation of their sensitivity to deflections is one of the most important aspects of their design and optimization procedures. The deflection test is performed in the actual gear mounting using completely processed gear. This test should cover the full operating range of gear loads from no load to peak load. Under peak load the contact pattern should extend to the tooth boundaries without showing a concentration of the contact pattern at any point on the tooth surface. Transmission error is tested on an axle assembly triaxial real car load condition.

  • PDF