This study simulates the operation of a 200 kW class micro gas turbine that is currently under development. The performance and operating characteristics depending on the load control scheme (constant turbine inlet temperature versus constant turbine exit temperature) and ambient condition were investigated using detailed component performance data. The sensitivities of operating parameters, such as the compressor surge margin and flow path temperatures, according to unit fuel flow change were predicted for a wide load range. The sensitivity analysis showed that the steady state calculation provided useful information about the maximum surge margin reduction during load change.

본 연구에서는 현재 개발중인 200kW 급 마이크로 가스터빈의 운전 특성을 모사하였다. 세부적인 성능 데이터를 이용하여 부분부하 제어방식(터빈 입구온도 제어방식(constant TIT control)과 터빈 출구온도 제어방식(constant TET control))과 외기온도에 따른 성능 및 작동특성을 분석하였다. 넓은 운전 범위에 대하여 압축기 서지마진과 터빈 입출구 온도 같은 작동 파라미터의 민감도를 단위 연료량 변화에 따라 예측하였다. 정상상태 계산으로 부분부하 변동 시 최대서지마진의 감소에 대한 정보를 민감도 분석을 통해 알 수 있다.

Keywords

References

  1. Rodgers, C. and Watts, J. and Nichols, K. and Brent, R., 2001, "Microturbines, in Distributed Generation," Borbely, A.M. and Kreider, J., ed., CRC Press, pp.119-150.
  2. Tan, E. S. and Zulhairi, M. A., 2012, " Feasibility of Biodiesel as Microturbine Alternative Fuel Through Atomization Characteristics Study," ASME GT2012-68039.
  3. Visser, W. P. J., Shakariyants, S. and De Later, M. T. L., 2012, "Performance Optimization of a 3kW Microturbine for CHP Applications," ASME GT2012-68686.
  4. Kim, B. S., Gil, Y. W. and Hong, W. P., 2009, " The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital Buildings," Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, Vol. 23, No, 12, pp. 176-183.
  5. Hong, W. P., Kim, B. S. and Cho, Y. S., 2010, " The Energy Performance Analysis of Micro Gas Turbine in Large Scale Store," Journal of the Korean Solar Energy Society, Vol. 30, No. 2, pp. 454-459.
  6. Oh, J. S. and Lee, H. S., 2002, " Prototype Development of a 75kW class Microturbine - Design/Manufacture and Self-Sustaining Test-," Proceedings of 2012 Annual Meeting of Korean Fluid Machinery Association, pp. 307-313.
  7. Kim, T. S. and Hwang, S. H., 2004, "Performance Characteristics for Off-design Operation of Micro Gas Turbines," Journal of Fluid Machinery, Vol. 7, No. 3, pp. 39-47. https://doi.org/10.5293/KFMA.2004.7.3.039
  8. Lee, J. J. and Kim, T. S., 2004, "Analysis of Operation Performance of a Micro Gas Turbine Generator System," Journal of Fluid Machinery, Vol. 8, No. 5, pp. 13-21.
  9. Kim, J. H., Jeon, Y. J., Kim, T. S. and Ro, S. T., 1999, "Analysis of the Dynamic Characteristics of a Small Regenerative Gas turbine," Trans. Korean Soc. Mech. Eng. B, Vol. 23, NO. 6, pp. 769-777.
  10. Park, J. H., 2011, "Practical Application of a 200kW Class Micro Gas Turbine Cogeneration System," Proceedings of 2011 Annual Meeting of Korean Fluid Machinery Association, pp. 491-494.
  11. Shin, H. D., Kang, D. W., Kim, T. S., Choi, M. k. and Park, P. J., 2012, "Design Parameter Sensitivity Analysis of a 200kW Class Micro Gas Turbine System," Journal of Fluid Machinery, Vol. 15, No. 6, pp. 39-45. https://doi.org/10.5293/kfma.2012.15.6.039
  12. Enter Software, Gasturb 9.0, 2001.
  13. Bruckner, R. J. and Puleo, B. J., 2008, "Compliant Foil Journal Bearing Performance at Alternate Pressures and Temperatures," ASME paper GT2008-50174.