Operating Characteristics of 5MW Class Gas Turbine Engine for Power Generation

5MW급 발전용 가스터빈 엔진의 작동 특성

  • 박준철 (두산중공업(주) 미래사업기술개발센터) ;
  • 홍성진 (두산중공업(주) 미래사업기술개발센터) ;
  • ;
  • 류제욱 (두산중공업(주) 미래사업기술개발센터)
  • Published : 2010.11.25

Abstract

Operating characteristics of DGT-5 being developed by Doosan Heavy Industries & Construction Co., Ltd. for power generation service was evaluated. Starting behavior was improved by a series of tests to investigate the effect of various fuel schedule and several combination of bleed valve control. The engine showed stable operation without any instability of compressor in the full operating regime covering from start-up to load conditions. If there is a rapid change of load in the condition of synchronization to Grid, the engine can be controlled stably based on the analysis of dynamic responses of the engine to an rapid load change and a sudden load rejection.

두산중공업(주)에서 개발 중인 발전용 가스터빈 DGT-5 엔진의 작동 특성을 평가하였다. 다양한 연료 스케쥴과 여러 가지 조합의 bleed valve 개폐 제어에 대한 영향을 분석하기 위한 시험을 통해 시동 특성을 개선하였고, 시동부터 부하운전 전체 작동 영역에서 압축기에서의 불안정 현상 없이 엔진이 안정적으로 작동됨을 확인하였다. 순간적인 부하 변동과 load rejection에 대한 엔진의 동적 거동 분석을 통해 실제 계통 병입 조건에서 급격한 부하변동 시 엔진이 안정적으로 제어될 수 있음을 확인하였다.