• Title/Summary/Keyword: Fuel Change

Search Result 1,359, Processing Time 0.026 seconds

Effects of Port Masking on fart Load Performance: Part II - Emission and Fuel Economy (포트 마스킹이 엔진의 부분부하 성능에 미치는 영향: Part II - 배기 및 연비특성)

  • 이원근;엄인용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.23-29
    • /
    • 2001
  • This paper is the second of companion papers, which investigate port-masking effects on emission and fuel economy. Port-masking was applied to commercial SOHC 3-valve engine by inserting masking plates between manifold and port. To induce various conditions of stratification, six types of masking plates were applied. In this paper, main interest is focused on the influence of injection timing on emission and fuel economy. Various injection timing was applied to the six cases, under the stoichiometric and lean-limit air-fuel ratio. Under the stoichiometric condition, an explanation about the reason of the change in emission level due to injection timing change is given. It is observed that NOx emission under the LML condition varies significantly when the injection timing changes.

  • PDF

The Influence of Source Term Release Parameters on Health Effects

  • Jeong, Jongtae;Ha, Jaejoo
    • Nuclear Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.294-302
    • /
    • 1999
  • The influence of source term release parameters on offsite health effects was examined for the YGN 3&4 nuclear power plants. The release parameters considered in this study are release height, heat content, and release time. The effects of core inventory change as a function of fuel burnup was also examined. The health effects by the change of release parameters are early fatalities, cancer fatalities, and early fatality distance. The results showed that early fatalities and early fatality distance decrease as release height increases, although it does not have significant influence on cancer fatalities. The values of both early and late health effects decrease as heat content increases. As release time increases, health consequence shows maximum value in 2 hours of release time and then decreases rapidly. As fuel burnup increases, early fatalities decrease rapidly, while cancer fatalities increase rapidly. Both cases show little variation afterward. Early fatality distance is almost same in all fuel turnup history. The information obtained through this research is very useful in developing strategies for reducing offsite consequences when combined with the influence of weather conditions on offsite risks.

  • PDF

DC/AC converters for the power generating system using fuel cell (연료전지 발전 시스템의 직류/교류 변환기)

  • Kim, Y.H.;Kwon, G.H.;Kim, J.S.;Jung, Y.H.;Choi, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1035-1037
    • /
    • 1992
  • Generally, fuel cell has characteristics of low voltage, large current and voltage variation under load change. Therefore, DC output voltage of fuel cell is too low to convert into AC with high efficiency and good performance. For this reason, fuel cell generating system is composed of DC-DC converter and inverter in cascade. This paper used 2-phase boost DC-DC converter to obtain low distortion waveform and reduce input-output current ripple, and discussed inverter which can be operated in independent drive mode and utility line interface drive mode. Then, the change of modes can be achived smoothly.

  • PDF

Transient response of unit PEMFC with the visualization study of cathode flooding under different stoichiometries (당량비 조건에 따른 PEM단위 연료전지의 과도 응답 특성 및 공기극 플러딩 연구)

  • Cho, Jun-Hyun;Kim, Han-Sang;Min, Kyoung-Doug
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.539-542
    • /
    • 2007
  • The transient response of PEMFC (proton exchange membrane fuel cell) is important criteria in the application of PEM fuel cell to real automotive system. In this work, using a transparent unit PEM fuel cell, the transient response and cathode flooding during load change are investigated. The cell voltage is acquired according to the current density change($0.3Acm^2$ to $0.6A/cm^2$) under various stoichiometry conditions and different flooding intensities, Also the cathode gas channel images are obtained by CCD imaging system simultaneously. The different level of undershoots appeared at the moment of load changes under different cathode stoichiometries and flooding intensities. The correlation of the dynamic behavior with stoichiometry and cathode flooding is induced from the results of these experiments.

  • PDF

Numerical Analysis of Combustion Characteristics during Combustion Mode Change of a Low NOx Utility Gas Turbine (발전용 저 NOx 가스터빈의 연소모드 변환시기의 연소특성 전산해석)

  • Jeong, Jai-Mo;Chung, Jae-Hwa;Park, Jung-Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.6
    • /
    • pp.127-134
    • /
    • 2004
  • Three-dimensional numerical investigations are carried out to understand the combustion characteristics inside a DLN(dry low NOx) utility gas turbine combustor during the combustion mode change period by applying transient fuel flow rates in fuel supply system as numerical boundary conditions. The numerical solution domain comprises the complex combustor liner including cooling air holes, three types of fuel nozzles, a swirl vane, and a venturi. Detailed three-dimensional flow and temperature fields before and after combustion mode changeover have been analyzed. The results may be useful for further studies on the unfavorable phenomena, such as flashback or thermal damage of combustor parts when the combustion mode changes.

Energy Saving and Development of an Industrial Regenerative Oxy-Fuel Combustion Furnace for CO2 Capture (에너지 절약 및 이산화탄소 포집을 위한 축열식 순산소 연소로 개발)

  • Oh, Jeongseog;Noh, Dongsoon;Lee, Daegeun;Hong, Sungkook;Yang, Jebok;Ko, Changbok;Lee, Eunkyung
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.121-122
    • /
    • 2013
  • In recent years, the usage of fossil fuels has caused problems of climate change and global warming. Because the combustion of fossil fuels is related to the production of greenhouse gases ($CO_2$, $CH_4$, etc.), new technology in the field of combustion is needed in order to handle the crisis of climate change and the global warming. As one of the efforts to reduce the emission of greenhouse gases, the concept of regenerative oxy-fuel combustion for energy efficiency and carbon capture was suggested, In the current study, the development of an industrial regenerative oxy-fuel combustion furnace was introduced, which has been being performed at Korea Institute of Energy Research (KIER).

  • PDF

Analysis of Fuelling Sequence and Fatigue Life for 4-Bundle Shift Refuelling Scheme in CANDU6 NPP

  • Namgung, Ihn
    • Nuclear Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.176-185
    • /
    • 2002
  • A 4-bundle shift refuelling method of CANDU6 F/H (Fuel Handling) System is analyzed to assess the operational flexibility and capacity of F/H system. The current 8-bundle shift refuelling scheme requires to refuel eight fuel bundles from a single fuel channel, and to refuel 14 fuel channels in a week on average assuming that the reactor is in a steady state. The analysis showed that the 4-bundle shift refuelling method increases F/M (Fuelling Machine) duty cycle and operator load. However, the fuellin’g method change from the 8- to 4-bundle shift refuelling ill not require additional team of operators. A marginal increase in the maintenance cost may be resulted in by the change of fuelling method and the increase of fatigue usage factors requires some components to be replaced during the FM lifetime.

Review for Applying Spent Fuel Pool Island (SFPI) during Decommissioning in Korea (원전해체시 독립된 사용후핵연료저장조 국내 적용 검토)

  • Baik, Jun-ki;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.163-169
    • /
    • 2015
  • In many nuclear power plant sites in Korea, high density storage racks were installed in the spent fuel pool to expand the spent fuel storage capacity. Nevertheless, the capability of the Hanbit nuclear site will be saturated by 2024. Also, 10 NPPs will reach their design life expiration date by 2029. In the case of the US, SFPI (Spent Fuel Pool Island) operated temporarily as a spent fuel storage option before spent nuclear fuels were transported to an interim storage facility or a final disposal facility. As a spent fuel storage option after shutdown during decommissioning, the SFPI concept can be expected to have the following effects: reduced occupational exposure, lower cost of operation, strengthened safety, and so on. This paper presents a case study associated with the regulations, operating experiences, and systems of SFPI in the US. In conclusion, the following steps are recommended for applying SFPI during decommissioning in Korea: confirmation of design change scope of SFPI and expected final cost, the submission of a decommissioning plan which is reflected in SFPI improvement plans, safety assessment using PSR, application of an operating license change for design change, regulatory body review and approval, design change, inspection by the regulatory body, education and commissioning for SFPI, SFPI operation and periodic inspection, and dismantling of SFPI.

Estimating Wildfire Fuel Load of Coarse Woody Debris using National Forest Inventory Data in South Korea

  • Choi, Suwon;Lee, Jongyeol;Han, Seung Hyun;Kim, Seongjun;Son, Yowhan
    • Journal of Climate Change Research
    • /
    • v.6 no.3
    • /
    • pp.185-191
    • /
    • 2015
  • This study presents an estimate of on-site surface fuel loadings composed of coarse woody debris (CWD) using $5^{th}$ National Forest Inventory (NFI) data in South Korea. We classified CWD data into forest type, region and decay class, and used conversion factors by decay class and tonne of oil equivalent developed in the country. In 2010, the total wildfire fuel load of CWD was estimated as 8.9 million TOE; those of coniferous, deciduous and mixed forests were 3.5 million TOE, 2.8 million TOE and 2.6 million TOE, respectively. Gangwon Province had the highest wildfire fuel load of CWD (2.3 million TOE), whereas Seoul exhibited the lowest wildfire fuel load of CWD (0.02 million TOE). Wildfire fuel loads of CWD were estimated as 2.9 million TOE, 1.9 million TOE, 2.4 million TOE and 1.7 million TOE for decay classes I, II, III and IV, respectively. The total wildfire fuel load of CWD corresponded to the calorific value of 8.2 million tons crude oil, 2.46% of that of living trees. Proportionate to the growing stock, total wildfire fuel load of CWD was in a broad distinction by region, while its TOE $ha^{-1}$ was not. This implies that there is no need to establish different guidelines by region for management of CWD. The results of this work provide a baseline study for scientific policy guidelines on preventing wildfires by proposing CWD as wildfire fuel load.

Application of Hyperion Hyperspectral Remote Sensing Data for Wildfire Fuel Mapping

  • Yoon, Yeo-Sang;Kim, Yong-Seung
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.1
    • /
    • pp.21-32
    • /
    • 2007
  • Fire fuel map is one of the most critical factors for planning and managing the fire hazard and risk. However, fuel mapping is extremely difficult because fuel properties vary at spatial scales, change depending on the seasonal situations and are affected by the surrounding environment. Remote sensing has potential to reduce the uncertainty in mapping fuels and offers the best approach for improving our abilities. Especially, Hyperspectral sensor have a great potential for mapping vegetation properties because of their high spectral resolution. The objective of this paper is to evaluate the potential of mapping fuel properties using Hyperion hyperspectral remote sensing data acquired in April, 2002. Fuel properties are divided into four broad categories: 1) fuel moisture, 2) fuel green live biomass, 3) fuel condition and 4) fuel types. Fuel moisture and fuel green biomass were assessed using canopy moisture, derived from the expression of liquid water in the reflectance spectrum of plants. Fuel condition was assessed using endmember fractions from spectral mixture analysis (SMA). Fuel types were classified by fuel models based on the results of SMA. Although Hyperion imagery included a lot of sensor noise and poor performance in liquid water band, the overall results showed that Hyperion imagery have good potential for wildfire fuel mapping.