• Title/Summary/Keyword: Frost characteristics

Search Result 161, Processing Time 0.026 seconds

A study on the performance of the finned tube heat exchanger affected by the frosting using CFD tool (전산해석을 이용한 착상이 핀튜브 열교환기 성능에 미치는 영향에 관한 연구)

  • Kim, Sung-Jool;Choi, Ho-Jin;Ha, Man-Yeong;Bang, Seon-Wook
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2738-2743
    • /
    • 2008
  • We conducted a study by computational simulation about the effects of frost thickness on the pressure drop and heat transfer characteristics as whole heat exchanger configuration changes. In order to perform the analysis for validation, we assumed that frost properties have constant values and the frost layers that are formed on the fin and tube surfaces are uniform. In order to find the constant thermal conductivity of frost layer, a variety of frost thermal conductivities are performed in our work and compared with the results by Lee et al. [4] and Yang et al. [5] proposed many experimental data about the 2-rows and 2-columns finned tube heat exchanger. The numerical results agreed well with the experimental data when frost conductivity is 0.07W/mK. After the validation had performed, we applied this procedure to the finned tube heat exchanger of domestic refrigeration and investigated the thermo-hydraulic characteristic of the heat exchanger affected by frost thickness according to the inlet velocities and temperatures of air considering the configuration change such as fin pitch.

  • PDF

Fin and Temperature Effect of Frost in Ambient Air Vaporizer

  • Lee, Seong-Woo;Choi, Sung-Woong
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.211-216
    • /
    • 2022
  • Since liquefied natural gas (LNG) is imported in a liquid state of about -162℃ to increase transportation efficiency in Korea, it must be vaporized in a gaseous state to supply it to consumers. Among them, ambient air vaporizer (AAV) has caught attention due to eco-friendly and low costs characteristics. However, there is a disadvantage that the performance of the heat exchanger is deteriorated due to frost due to mist and icing when used for a long time. In this paper, frost generation model in AAV vaporizer was investigated with numerically to examine utilizing the vaporizer performance with the frost generation behavior. The frost generation behavior of AAV vaporizers was examined with humidity, fin characteristic, and temperature effects. As for the LNG discharge temperature, the 12 fin vaporizer showed the highest discharge temperature when the atmospheric temperature was 25℃, and the 8 fin vaporizer had the lowest LNG discharge temperature when the atmospheric temperature was 0℃. In the case of frost formation, in the case of the 12 fin vaporizer, it was formed the most at the atmospheric temperature of 25℃, and the least was formed in the vaporizer at the 0℃ condition of the atmospheric temperature of 8 fins.

Experimental Assessment and Specimen Height Effect in Frost Heave Testing Apparatus (동상시험장비의 실험적 검증 및 시료크기의 영향에 관한 연구)

  • Jin, Hyunwoo;Ryu, Byunghyun;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Frost heave is one of the representative engineering characteristics in cold regions. In South Korea, which is located in seasonal frost area, structural damage caused by frost heave and thaw happens and the need for research on the frost heave is increasing. In this paper, newly developed transparent temperature-controllable cell is used to focus on the frost heave. Frost susceptible artificial soil is used to analyze water intake rate which is one of the important factors in frost susceptibility criteria. Frost heave rate and water intake rate have similar behavior after heave by freezing of pore water converges. O-ring installed in the upper pedestal to measure water intake rate generates side friction between the inner wall of the freezing cell and O-ring, thereby hindering frost heave. Therefore, the frost susceptibility criteria using the water intake rate is not reliable. It is appropriate to use frost heave rate which has similar behavior with water intake rate. Frost heave tests were performed under two different specimen heights. Overburden pressure, temperature gradient and dry unit weight were set under similar state. Based on laboratory testing results, frost heave is independent on the specimen height.

Characteristics and Trends of Spatiotemporal Distribution of Frost Occurrence in South Korea for 21 Years (21년간 한국의 서리발생 시·공간 분포 특성과 경향)

  • Jo, Eunsu;Kim, Hae-Min;Shin, Ju-Young;Kim, Kyu Rang;Lee, Yong Hee;Jee, Joonbum
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.2
    • /
    • pp.83-94
    • /
    • 2022
  • In order to actively prepare to frost damage that occurs in the process of growing crops, the spatial and temporal distribution of frost occurrence in South Korea was derived using frost observation data from 20 regions over the past 21 years (2000~2020). The main products are the number of frost days, first frost day, and last frost day by region. And the climatic trends of these results were identified by performing the Mann-Kendall trend test and Sen's slope estimator. In South Korea, a lot of frost occurs in the inland area to the west of the Taebaek and Sobaek Mountains. Relatively closer to the coastal area, the number of frost days is small, the first frost day is slow, and the last frost day is early. The east coast region has fewer frost days, the first frost day is later, and the last frost day is earlier than the west coast region. The southern sea, the southeastern sea region, and the island region rarely experience frost. As a result of the annual time series trend analysis, although South Korea is a country where climate warming is progressing, there was no trend in reducing the number of frost days and slowing the first frost day, and it was found that the last frost day is delayed by 0.5 days per year.

Evaluation on the Reliability of Frost Susceptibility Criteria (동상민감성 판정 기준 신뢰성에 관한 연구)

  • Jin, Hyunwoo;Ryu, Byunghyun;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.12
    • /
    • pp.37-45
    • /
    • 2017
  • Structural instability and damage are caused by frost heave during the winter when atmospheric temperature maintains below $0^{\circ}C$. Frost heave is the most representative engineering characteristics of frozen ground and there are various frost susceptibility criteria. Frost susceptibility criteria can be roughly divided into three categories. First, frost susceptibility is determined from particle size distribution, which is practically useful and many countries are adopting. In this paper, several particle size distributions (PSDs) are applied to the frost susceptibility criteria but PSD seems to be not enough to determine whether soils are frost susceptible. Second, it is judged from laboratory frost heave testing results. Laboratory frost heave tests were performed with newly developed thermal controlled triaxial cell and the reliability of frost susceptibility criteria is evaluated. New testing apparatus and method are suitable to meet the existing frost susceptibility criteria. Third, it is compositive frost susceptibility criteria envelope including the particle size distribution, soil classification, and frost heave test. The compositive frost susceptibility criteria envelope should be supplemented based on additional data on various soil types.

The Weather Characteristics of Frost Occurrence Days for Protecting Crops against Frost Damage (서리 피해 방지를 위한 서리 발생일의 기상 특성에 대한 연구)

  • Kwon, Young-Ah;Lee, Hyo-Shin;Kwon, Won-Tae;Boo, Kyung-On
    • Journal of the Korean Geographical Society
    • /
    • v.43 no.6
    • /
    • pp.824-842
    • /
    • 2008
  • The main objective of the study was to analyze the weather conditions of frost occurrence for protecting crops against frost damage in Korea. The primary data used for the analysis of meteorological characteristics of frost occurrence days are the airmass pattern, minimum temperature, grass minimum temperature, daily temperature range, relative humidity, minimum relative humidity, mean wind speed in autumn and spring. Frost often occurs when the migratory anticyclone passes the southwest of Korea. The importance of grass minimum temperature measurements for agricultural purposes has previously been recognized. The grass minimum thermometer is capable of detecting ground frosts which are often not recorded by the minimum thermometer. The minimum temperature of frost occurrence days is above $0^{\circ}C$ in the coastal area, but the grass minimum temperature of frost occurrence days is below $0^{\circ}C$ in the whole area. The daily temperature of frost occurrence days is about 9 to $12^{\circ}C$ in the coastal area and is over $14^{\circ}C$ in the inland area. The minimum relative humidity of frost occurrence days is about 30 to 50%. The mean wind speed of frost occurrence days is less than 2m/sec.

Development and Verification of High Efficiency Experimental Apparatus to Evaluate Freezing Phenomenon of Soils (고효율 실내 동결실험장비의 개발 및 성능검증)

  • Choi, Chang-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.93-103
    • /
    • 2011
  • In order to design suitable geo-structures in cold region, it is generally required to consider the mechanical properties of permafrost soils. 'Frost heave' as one of the primary phenomenon is considered to be an important factor together with 'adfreeze bond-strength' and 'creep deformation' for structural design process in permafrost area. Therefore, the fundamental study for frost heave has to be preceded for design of geo-structures in cold region. While various experimental apparatuses have been developed, there still exist a certain level of limitation to evaluate the frost-heave characteristics as design parameters. In this paper, a new type of experimental apparatus is proposed to evaluate the engineering characteristics of frost heave in permafrost soils and a set of verification test results is presented. Based on the verification tests, the proposed apparatus is a suitable to obtain frost characteristics of soils.

Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition (착상조건하에서 평행 평판 열교환기의 열 및 물질전달)

  • Lee, K.S.;Lee, T.H.;Kim, W.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

Geotechnical Characteristics of Frost-Susceptibility Soil Using Modified Freeze-Thaw Apparatus (변형된 동결-융해 시험장치를 이용한 동상민감성흙의 지반공학적 특성)

  • Shin, Eun-Chul;Ryu, Byung-Hyun;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • A new system of modified freeze-thaw testing apparatus is introduced. This system is developed to evaluate the geotechnical parameters and their dependence upon freezing-thawing history of frost-susceptibility soil. A necessary condition for stationary frost heaving is clarified in this paper. The method changes the thermal boundary condition up to the net heat flow at the freezing frost becomes zero. The effectiveness of this method is verified by freeze-thaw tests. Frost heaving observed after the application of the method is found to be due to another frost heaving action called long-term frost heaving. This frost heaving has already been studied and is considered ignorable as engineering factor because of its small heaving amount.

  • PDF

Effects of Humidity and Velocity on Frost Distribution Characteristics of Humid Air Flow on Cold Surfaces (차가운 표면위에서의 습공기 유동의 습도 및 속도가 착상분포 특성에 미치는 영향)

  • Kwon Jeong-Tae;Rew Keun-Ho;Lim Hyo-Jae;Han Ji-Won;Kwon Young Chul
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.213-218
    • /
    • 2005
  • In order to understand the heat and mass transfer characteristics of humid airflow in frosting conditions, a flat plate of aluminum with cooling modules located in the central part of the plate was used. A microscope system (resolution of 0.05 mm) was used for the measurement of local thickness of frost at seven points along the plate in the flow direction. For the total mass of frost at each test operation, an electronic balance (resolution of 1 mg) was used. The local frost thickness distributions far various test conditions were presented along with the frost mass data measured at the given operating times. The effect of humidity and velocity of humid air on frosting were analyzed.