• Title/Summary/Keyword: Friction loss calculation

Search Result 18, Processing Time 0.022 seconds

Effectiveness of Friction Loss Calculation Used for Water Mist Fire Extinguishing System on Marine Vessels

  • Lee Kyung-Woo;Kim You-Taek;Lee Young-Ho;Kim Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.86-97
    • /
    • 2005
  • Nowadays, Water Mist Fire Extinguishing System is increasingly used in maritime field for various application. The fire extinguishing capability of the system should be verified by hydraulic calculation in the same manner as the conventional water based fire extinguishing system such as sprinkler system. water spray system and etc. Additionally, the review of effectiveness of friction loss calculation method used for hydraulic calculation is needed because the pipe flow characteristic of its piping system has higher Reynolds number than that of the conventional system. In this paper the review work was carried out based on the NFPA Code 750.

An Experimental Study on The Frictional Loss of Stress in The Prestressing Tendons (PS 긴장재의 마찰손실량에 관한 실험적 연구)

  • 정배근;한경봉;박선규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.417-422
    • /
    • 2000
  • In prestressed concrete structures, determining serviceability and safety it is important to exactly calculate effective prestress force acting on structures. for the determination of effective prestress force, friction loss of the prestressing tendon should be decided exactly, but it is very difficult to measure the exact prestress force on the site and there is no actual field data. Therefore the friction loss coefficient recommended by the specification is not verified. in this paper, the friction loss standard PSC-Beam will be investigated, and is will be found what kind of relationship between the specification and the site. The results from this study can be summarized as follows. For jacking at both ends, actual intial prestress force in the center section of PCS-Beam was about 1.61% larger than theoretical initial prestress force and for hacking at one end, actual initial prestress force was approximate 4.9% lower than theoretical initial prestress force. Thus, for the exact calculation of friction loss, friction coefficient should be modified according to jacking methods.

  • PDF

The Problem of Engine Friction Test by Strip Down Method (스트립 다운에 의한 엔진 마찰 시험의 문제점)

  • Cho, Myung-Rae;Oh, Dae-Yoon;Han, Dong-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2429-2435
    • /
    • 2002
  • The aim of this paper is to investigate the problem of strip down method, which is usually used to evaluate the engine friction level. The validity of strip down method was investigated by theoretical analysis of friction in crank and piston assembly. The friction of cylinder and piston assembly was analyzed under the various test conditions. The measured cylinder pressure was used as boundary conditions of friction torque and loss calculation. The friction loss of crank and piston assembly was influenced by test conditions that resulted from the variation of load condition. From the results, we have known that the strip down method could be possible to distort the friction loss of engine moving components.

Simple Equivalent Circuit for Efficiency Calculation of Brushless DC Motors

  • Ishikawa, Takeo;Tsuji, Takuma;Hashimoto, Seiji;Kurita, Nobuyuki
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • This paper shows a calculation method of several types of loss and the efficiency of brushless DC motors coupled with a load system by using a simple equivalent circuit, in which copper loss, eddy current loss, hysteresis loss, friction loss, viscous loss, and inverter loss are taken into account. We clarify each loss and motor efficiency at different motor speeds and different output torques by using the Microsoft-Excel. Moreover, the calculated results are in good agreement with the measured ones.

A Study on Hydraulic Calculation Procedure of Fire Sprinkler System Design (스프링클러설비 설계의 수리계산 절차에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.24-32
    • /
    • 2018
  • There are two kinds of method on hydraulic calculation of fire sprinkler system design. The one is using the computational program and the other is designer calculate system for oneself. In case of using the computational program, putting the input data in, the program calculate the friction loss, water flow, total height and so forth. If program user or designer doesn't know the basic idea and procedure of hydraulic calculation. Then, the outputs are different from each other. This paper suggests the hydraulic calculation procedure in design area as follow. Equivalent lengths of tees on the branch are selected base on the same pipe diameter which the tees are established, although the diameter of tee outlet is different. Even though there is a different friction loss of head from the other head, the pressure from the hydraulic end is bigger than a head loss, discharge flow is calculated by pressure from the hydraulic end.

Evaluation of Head Loss within In-Line Mixer for Water Treatment using CFD Technique (CFD모사 기법을 이용한 관내 혼화장치내 수두손실 발생 특성 평가)

  • Hwang, Young-Jin;Lim, Sung-Eun;Kim, Seong-Su;Park, No-Suk;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.107-112
    • /
    • 2009
  • This study was conducted for verification and systematization of estimation method about the headloss using CFD(Computational Fluid Dynamics). Head loss which happens between the inlet and outlet of in-line mixer can be a major factor for the design and construction. Also, this Case studies about the sensitivity related to the velocity in the piping system. As result, program's default calculation function was used to get each side's total pressure and the differential of each total pressure could be defined as head loss from in-line mixer. In the case of adopting pipe surface friction factor and geometry loss, Calculation residual can be much more reduced. It was found that residual of value between CFD method and field test ranged about 3 through 18 precent.

Performance Prediction of Centrifugal Compressors (원심 압축기의 성능 예측)

  • 오형우;정명균
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.136-148
    • /
    • 1997
  • The present study has been carried out to develop a computational procedure for the analysis of the off-design performance in centrifugal compressors with vaneless diffusers by integrating empirical loss models and analytical equations. Losses in centrifugal compressors stem from a number of sources and their exact calculation is not yet possible. This study investigates several modeling schemes and shows that a fairly good prediction can be achieved by a proper selection of the most important flow parameters resulting form a meanline one-dimensional analysis. The performance maps for compressors are calculated and compared with measured performance maps. The off-design performance characteristics in terms of the pressure ratio vs. mass flow produced have generally correct forms. However, no universal means have been found to predict accurately the onset of surge. The prediction method developed through this study can serve as a tool to ensure good matching between parts and it can assist the understanding of the operational characteristics of general purpose centrifugal compressors.

  • PDF

Lubrication Modeling of Reciprocating Piston in Piston Pump with High Lateral Load (강한 측력이 작용하는 피스톤 펌프의 왕복동 피스톤 기구 부에서의 윤활모형에 관한 연구)

  • Shin, JungHun;Jung, DongSoo;Kim, KyungWoong
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.116-123
    • /
    • 2014
  • The objective of this study is to model and simulate the nonlinear lubrication performance of the sliding part between the piston and cylinder wall in a hydrostatic swash-plate-type axial piston pump. A numerical algorithm is developed that facilitates simultaneous calculation of the rotating body motion and fluid film pressure to observe the fluid film geometry and power loss. It is assumed that solid asperity contact, so-called mixed lubrication in this study, invariably occurs in the swash-plate-type axial piston pump, which produces a higher lateral moment on the pistons than other types of hydrostatic machines. Two comparative mixed lubrication models, rigid and elastic, are used to determine the reaction force and sliding friction. The rigid model does not allow any elastic deformation in the partial lubrication area. The patch shapes, reactive forces, and virtual local elastic deformation in the partial lubrication area are obtained in the elastic contact model using a simple Hertz contact theory. The calculation results show that a higher reaction force and friction loss are obtained in the rigid model, indicating that solid deformation is a significant factor on the lubrication characteristics of the reciprocating piston part.

Simulation of the gas exchange process for single-cylinder 4-stroke cycle spark ignition engine (단기통 4사이클 스파아크 점화기관 흡.배기 과정의 시뮬레이션)

  • 윤건식;유병철
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.7 no.1
    • /
    • pp.24-34
    • /
    • 1985
  • The study of unsteady gas exchange processes in the inlet and exhaust systems of the single-cylinder 4-stroke cycle spark ignition engine is presented in this paper. The generalized method of characteristics including friction, heat transfer, change of flow area and entropy gradients was used for solving the equations defining the gas exchange process. The path line calculation was also conducted to allow for calculation of the gas composition and entropy change along the path lines, and of the variable specific heat due to the change of temperature and composition. As the result of the simulation, the properties at each point in the inlet and exhaust pipe, pressure and temperature in the cylinder, and charging efficiency were obtained. Pumping loss and residual gas fraction were also computed. The effect of engine speed, exhaust and inlet pipe length on the pumping loss and charging efficiency were studied showing that the results were in agreement with what has been known from experiments.

  • PDF

A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System (Loop형 스프링클러 설비의 수리계산 방법에 대한 제시)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • There are three kinds of design method of the fire sprinkler systems. Grid type is connected all branch as a trapezoid. Loop type is connected cross-mains like circle. The last one is a tree type most commonly used. Grid type needs computer program to calculate the friction loss and flow rate apart from very simple form. In loop type, manual calculation is possible. Design engineer can draw up and calculate the demands without computer program. Because water supplies two direction in loop type, friction loss is smaller than tree type. Water distribution in operation area is uniform because of the small differences of sprinklers discharge pressure. Loop type is superior to tree type in respect of total pressure and flow rate. Using the small diameter pipe, the labor and construction cost will be decreased in the end. Loop type sprinkler design is rarely laid out because design engineers don't know the method. This paper is intended to inform that the loop type is better than the tree type in performance and economic point of view. And also this paper intend to use the loop type easily and widely.