• 제목/요약/키워드: Fretting Fatigue Limit

검색결과 16건 처리시간 0.025초

재질 열화와 프레팅 피로거동 평가에 관한 연구 (A Study on Material Degradation and Fretting Fatigue Behavior)

  • 권재도;성상석;최성종
    • 대한기계학회논문집A
    • /
    • 제25권8호
    • /
    • pp.1287-1293
    • /
    • 2001
  • Fretting is a potential degradation mechanism of structural components and equipments exposed to various environments and loading conditions. The fretting degradation, for example, for example, can be observed in equipments of nuclear, fossil as well as petroleum chemical plants exposed to special environments and loading conditions. It is well known that a cast stainless steel(CF8M) used in a primary reactor coolant(RCS) degrades seriously when that material is exposed to temperature range from 290$\^{C}$∼390$\^{C}$ for long period. This degradation can be resulted into a catastrophical failure of components. In the present paper, the characteristics of the fretting fatigue are investigated using the artificially aged CF8M specimen. The specimen of CF8M are prepared by an artificially accelerated aging technique holding 180hr at 430$\^{C}$ respectively. Through the investigations, the simple fatigue endurance limit of the virgin specimen is not altered from that obtained from the fatigue tests imposed the fretting fatigue. The similar tests are performed using the degraded specimen. The results are not changed from those of the virgin specimen. The significant effects of fretting fatigue imposed on both virgin and degraded specimen on the fatigue strength are not found.

스틸 휠 굽힘 모멘트 내구시험의 내구신뢰성 개선에 대한 연구 - 스틸 휠 접촉면의 프랫팅 제거 - (A Study for Improvement of Cornering Fatigue Test by Eliminating a Fretting Effect on Steel Wheel to enhance Durability and Reliability)

  • 정수식;정원욱;유연상;강우종;김대성;권일기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1326-1330
    • /
    • 2008
  • The failure mode of steel road wheels in a vehicle is cracks from ventilation hole through to contact plane on steel wheel's disc plate. But a number of cracks of Cornering Fatigue Limit Test is on contact plane near to wheel nut mounting area, even though it's satisfied with specified cycles. So this paper searches out causes to improve durability and reliability of C.F.T by uni-axial bending moment test. The verified cause is a "fretting" on contact area of steel wheel. In result, this paper suggests a solution to prevent a fretting by inserting a damping shim, 0.7mm between steel wheel contact areas. Therefore this paper makes it possible to move crack position of C.F.T in steel wheel from contact plane to vehicle's failure mode.

  • PDF

경년열화가 가공송전선(STACIR/AW)용 강심소재 Al Clad Invar 강선의 피로에 미치는 영향 ( 1 ) (Effect of Aging on fatigue of Al Clad INVAR Core Wire for High Capacity and Low Sag(STACIR/AW) Conductor ( 1 ))

  • 김상수;김병걸;현석규;신구용;이동일;민병욱
    • 한국전기전자재료학회논문지
    • /
    • 제19권1호
    • /
    • pp.91-99
    • /
    • 2006
  • Fatigue properties of INVAR/AW wires have been investigated under the heat exposure in order to ensure stable operation and to estimate life span of their power line. In the case of heat exposure for 10000 hr, fatigue life and limit increased. For further heat exposure, fatigue limit decreased due to the decrease in yield strength. The variation fatigue of strand wire was strongly dependent on its amplitude. Also, cracks in wires of 7 strands were caused by stress concentration at the outer surface and fretting between each wire during vibration.

미소피로균열의 검출과 정류균열 (Detection and non-propagating cracks of small fatigue crack)

  • 이종형
    • 대한기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.603-609
    • /
    • 1990
  • 본 연구에서는 미소균열의 정의로서 균열의 크기가 재료의 조직의 크기와 order적으로 같은 균열의 특성이라는 것과 균열의 크기가 소성역 크기와 order적으로 같은 균열의 특성에 착안해서 탄소강 평활재와 예균열재(pre-cracked specimen)에 대 해서 응력비 R=-1 및 R=0의 피로한도 특성과 평활재의 미소균열의 검출 및 정류균열의 생성기구를 균열 열림 닫힘에 주목해서 검토하였다.

와전류탐상검사에 의한 튜브엔드 슬리브 건전성 검증 (The Integrity Verification of Tube-end Sleeve by ECT)

  • 김수진;권경주;석동화;박기태
    • 한국압력기기공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.20-24
    • /
    • 2015
  • Steam generator(S/G) tubes in pressurized water reactor (PWR's) are subject to several types of degradation. This degradation includes denting, pitting, intergranular attack(IGA), intergranular stress corrosion cracking(IGSCC), fatigue, fretting and wear. Degradation can be derived from either the primary side(inside) or the secondary side(outside) of the tube. Recent issue for tube degradation in domestic steam generator is the tube end cracking on seal weld region. The seal weld region at the tube end and tube itself is regarded as a pressure boundary between the primary side and the secondary side. One of the Westinghouse Model-F S/G has experienced tube end cracking and its number of plugging approximately becomes to the operating limit up to 5% due to tube end cracking which was reported as SAI/MAI(single/multiple axial indication) or SCI/MCI(Single/multiple circumferential indication) from the results of eddy current testing. Eddy current mock-up test was carried out to determine the origin of cracking whether it is from weld zone area or parent tube. This result was helpful to analyze crack location on ECT data. Correct action on this problem was the installation of tube-end sleeve. Last year, after removing 340 installed plugs from tubes, selected 269 tubes took tube-end sleeve installation. Tube-end sleeve brought pressure boundary from parent tube to installed sleeve tube. Tube-end sleeve has the benefit of reducing outage period and increasing more revenue than replacing S/G. This paper is provided to assist interest parties in effectively understanding this issue.