DOI QR코드

DOI QR Code

The Integrity Verification of Tube-end Sleeve by ECT

와전류탐상검사에 의한 튜브엔드 슬리브 건전성 검증

  • 김수진 (한전KPS 원자력정비기술센터) ;
  • 권경주 (한전KPS 원자력정비기술센터) ;
  • 석동화 (한전KPS 원자력정비기술센터) ;
  • 박기태 (한전KPS 원자력정비기술센터)
  • Received : 2015.05.04
  • Accepted : 2015.06.25
  • Published : 2015.06.30

Abstract

Steam generator(S/G) tubes in pressurized water reactor (PWR's) are subject to several types of degradation. This degradation includes denting, pitting, intergranular attack(IGA), intergranular stress corrosion cracking(IGSCC), fatigue, fretting and wear. Degradation can be derived from either the primary side(inside) or the secondary side(outside) of the tube. Recent issue for tube degradation in domestic steam generator is the tube end cracking on seal weld region. The seal weld region at the tube end and tube itself is regarded as a pressure boundary between the primary side and the secondary side. One of the Westinghouse Model-F S/G has experienced tube end cracking and its number of plugging approximately becomes to the operating limit up to 5% due to tube end cracking which was reported as SAI/MAI(single/multiple axial indication) or SCI/MCI(Single/multiple circumferential indication) from the results of eddy current testing. Eddy current mock-up test was carried out to determine the origin of cracking whether it is from weld zone area or parent tube. This result was helpful to analyze crack location on ECT data. Correct action on this problem was the installation of tube-end sleeve. Last year, after removing 340 installed plugs from tubes, selected 269 tubes took tube-end sleeve installation. Tube-end sleeve brought pressure boundary from parent tube to installed sleeve tube. Tube-end sleeve has the benefit of reducing outage period and increasing more revenue than replacing S/G. This paper is provided to assist interest parties in effectively understanding this issue.

Keywords

References

  1. Swilley, S., 2007, "Pressurized Water Reactor Steam Generator Examination Guidelines", Revsion 7, pp. 3-2. 6-5-6-6.
  2. Mcllree, A. R., 1997, "PWR Steam Generator Sleeving Assessment Document", Revision 1, pp. 1-1-1-6,
  3. Kepco KPS, 2014, "Final Report of Steam Generator De-plugging and Tube End Sleeve Installation at HB Unit2", pp. 1-29.
  4. Westinghouse Electric germany GmbH, 2014, "Sleeving of Steam Generator tubes PLUSS Sleeve"