• Title/Summary/Keyword: Frequency weighting

Search Result 326, Processing Time 0.06 seconds

Study on Discomfort of Vertical Whole-body Shock Vibration Having Various Magnitudes, Frequencies and Damping (다양한 크기와 주파수 그리고 감쇠를 갖는 상하방향 전신 충격진동에 대한 불편함 연구)

  • Ahn, Se-Jin;Griffin, Michael J.;Yoo, Wan-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.50-57
    • /
    • 2007
  • Shocks are excited by impulsive forces and cause discomfort in vehicles. Current standards define means of evaluating shocks and predicting their discomfort, but the methods are based on research with a restricted range of shocks. This experimental study was designed to investigate the discomfort of seated subjects exposed to a wide range of vertical shocks. Shocks were produced from the responses of one degree-of-freedom models, with 16 natural frequencies (from 0.5 to 16 Hz) and four damping ratios (0.05 0.1, 0.2 and 0.4), to a hanning-windowed half-sine force inputs. Each type of shock was presented at five vibration dose values in the range $0.35\;ms^{-1.75}$ to $2.89\;ms^{-1.75}$. Fifteen subjects used magnitude estimation method to judge the discomfort of all shocks. The exponent in Stevens' power law, indicating the rate of growth in discomfort with shock magnitude, decreased with increasing fundamental frequency of the shocks. At all magnitudes, the equivalent comfort contours showed greatest sensitivity to shocks having fundamental frequencies in the range 4 to 12.5 Hz. At low magnitudes the variations in discomfort with the shock fundamental frequency were similar to the frequency weighting $W_b$ in BS 6841, but low frequency high magnitudes shocks produced greater discomfort than predicted by this weighting. At some frequencies, for the same unweighted vibration dose value, there were small but significant differences in discomfort caused by shocks having different damping ratios. The rate of increase in discomfort with increasing shock magnitude depends on the fundamental frequency of the shock. In consequence, the frequency-dependence of discomfort produced by vertical shocks depends on shock magnitude. For shocks of low and moderate discomfort, the current methods seem reasonable, but the response to higher magnitude shocks needs further investigation.

Directive Spectrum Analyzing System Using a Linear Hydrophone Array (직선배열 hydrophone에 의한 수중음원의 분석)

  • CHANG Jee-Won;JEONG Jung-Hyun;SUR Doo-Og
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.265-268
    • /
    • 1981
  • The direction and spectra of underwater sound wave were a remarkable contrast to the sound wave in the air because of the difference of transmissive medium. The linear hydrophone array of passive system has so far been applied to find out the direction and spectra of underwater sound wave from the sources for many purposes. The conventional methods are generally classified into two systems such as, the system which varying frequency responses, other parameters and pattern of signal like an adaptive array controlled by internal feedback, and another system which obtaining maximum of S/N ratio by giving a appropriate delay and a weighting coefficient in the output of each hydrophone. The array device of passive system can easily change the amplitude and the phase of signal by separately controlled hydrophone. And here we introduce a method that the spectral analyzing and the direction finding can be simultaneously carried out using a linear array of hydrophones. By making a circular convolution of output of signal from each hydrophone with appropriate rectangular weighting coefficient on the array, a sharp response of single lobe directivity and the spectral analyzing by time averaging were simultaneously obtained. In tile computer simulation of the array system with the length of 250cm and the interhydrophone distance of l0cm the power levels of sound signals received from given array direction were 16dB higher than those from the other directions when processing with rectangular weightings, and 8dB higher when processing with rectangular sound signals and rectangular weightings.

  • PDF

A Study on the Load Frequency Control of Power System Using an Optimal Modulation Controller (최적 변조제어기를 이용한 전력시스템의 부하주파수 제어에 관한 연구)

  • 정형환;허동렬;정문규;주석민;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.299-306
    • /
    • 2002
  • The load frequency control(LFC) of power system is one of important subjects in view of system operation and control. That is, even though the rapid load disturbances are applied to the given power system, the stable and reliable power should be supplied to the users, converging unconditionally and rapidly the frequency deviations and the tie-line power flow ones of each area into allowable boundary limits. Nonetheless of such needs, if the internal parameter perturbation and the sudden load variation are given, the unstable phenomena of power systems can be often brought out because of the large frequency deviation and the unsuppressible power line one. So, an optimal modulation controller for UC of multi-area power system is designed by a recursive algorithm that determines the state weighting matrix Q of a linear quadratic performance criterion. The optimal modulation controller is based on optimal control and can obtain the exact dynamic response of the UC of multi-area power system in the time domain. The performances of the resultant optimal modulation control, that is, the steady-state deviations of frequency and tie-line power flow and the related dynamics, were investigated and analyzed in detail by being applied to the UC of multi-area power system in the perturbations of predetermined internal parameters. Through the simulation results tried variously in this paper for disturbance of stepwise load changes, the superiorities of the proposed optimal modulation controller in robustness and stability were proved.

Robust tuning of quadratic criterion-based iterative learning control for linear batch system

  • Kim, Won-Cheol;Lee, Kwang-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.303-306
    • /
    • 1996
  • We propose a robust tuning method of the quadratic criterion based iterative learning control(Q-ILC) algorithm for discrete-time linear batch system. First, we establish the frequency domain representation for batch systems. Next, a robust convergence condition is derived in the frequency domain. Based on this condition, we propose to optimize the weighting matrices such that the upper bound of the robustness measure is minimized. Through numerical simulation, it is shown that the designed learning filter restores robustness under significant model uncertainty.

  • PDF

A Studyon the Equivalent Model Transformation of the Discrete Linear Systems (이산 선형 시스템의 등가 모델 변환에 관한 연구)

  • 임승우;김정화;정찬수
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1991.10a
    • /
    • pp.215-219
    • /
    • 1991
  • This paper is equivalent model transform which reduces the restriction of digitalization in the discrete linear system. This algorithm is the method that weight is given to contribillity and obserbility gramian, the regular matrix T of coordinate transform is obtained and then the state space coefficents of weighted model can be obtained. This study shows the frequency reponse of low quantization error according to the order of weighting function. The result shows that frequency response of the proposed algorithm is better than that of the balanced realization in the system of smaller bit.

Changes in Transmitting-Receiving Characteristics of Underwater Acoustic Transducer by Transformer (트랜스포머에 의한 수중 음향 트랜스듀서의 송수신 특성의 변화)

  • 조치영;이정민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.493-499
    • /
    • 1997
  • In this study, the changes in transmitting and receiving characteristics, especially resonance frequencies, of the underwater acoustic planar array transducer by the transformers used in the analog weighting circuit are investigated. Electrical equivalent circuit analysis shows that an ideal transformer does not change the resonance frequency of the transmitting mode, but the resonance frequency which gives the maximum receiving sensitivity can be designed by adjusting the magnitude of reactance of transformer.

  • PDF

A Simple Method for Frequency Domain Identification

  • Choe, Yeon-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.129-134
    • /
    • 1998
  • In this paper, a simple method is presented to synthesize a transfer function from experimentally obtained gain and phase data. The method we offer here is based on the previous method given by M.Hassul etc. [1], where they proposed relevant formulas in a straightforward manner so that undergraduate students could follow the development more easily. This method, however, inevitably is accompanied by a significant difference between the real and identified model especially in the low frequency region. We solve this problem by introducing a new weighting function that can be determined by using the additive uncertainty of the Identified transfer function.

  • PDF

Performance analysis and experiment results of multiband FSK signal based on direct sequence spread spectrum method (직접 수열 확산 방식 기반 다중 밴드 FSK 신호의 성능 분석 및 실험 결과)

  • Jeong, Hyun-Woo;Shin, Ji-Eun;Jung, Ji-Won
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.370-381
    • /
    • 2021
  • This paper presented an efficient transceiver structure of multiband Frequency Shift Keying (FSK) signals with direct sequence spread spectrum for maintaining covertness and performance. In aspect to covertness, direct sequence spread spectrum method, which multiplying by Pseudo Noise (PN) codes whose rate is much higher than that of data sequence, is employed. In aspect to performance, in order to overcome performance degradation caused by multipath and Doppler spreading, we applied multiband, turbo equalization, and weighting algorithm are applied. Based on the simulation results, by applying 4 number of multiband and number of chips are 8 and 32, experiments were conducted in a lake with a distance of moving from 300 m to 500 m between the transceivers. we confirmed that the performance was improved as the number of bands and chips are increased. Furthermore, the performance of multiband was improved when the proposed weighting algorithm was applied.