• 제목/요약/키워드: Frequency protection

검색결과 875건 처리시간 0.034초

Comparative Study between Two Protection Schemes for DFIG-based Wind Generator Fault Ride Through

  • Okedu, K.E.;Muyeen, S.M.;Takahashi, R.;Tamura, J.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권1호
    • /
    • pp.8-16
    • /
    • 2012
  • Fixed speed wind turbine generators system that uses induction generator as a wind generator has the stability problem similar to a synchronous generator. On the other hand, doubly fed induction generator (DFIG) has the flexibility to control its real and reactive powers independently while being operated in variable speed mode. This paper focuses on a scheme where IG is stabilized by using DFIG during grid fault. In that case, DFIG will be heavily stressed and a remedy should be found out to protect the frequency converter as well as to allow the independent control of real and reactive powers without loosing the synchronism. For that purpose, a crowbar protection switch or DC-link protecting device can be considered. This paper presents a comparative study between two protective schemes, a crowbar circuit connected across the rotor of the DFIG and a protective device connected in the DC-link circuit of the frequency converter. Simulation analysis by using PSCAD/EMTDC shows that both schemes could effectively protect the DFIG, but the latter scheme is superior to the former, because of less circuitry involved.

국제규격 대응 컴퓨터 네트워크용 서지방호장치 개발에 관한 연구 (A Study on the Surge Protection Device for Computer Networks by International Standards)

  • 박대원;서황동;송재용;한주섭;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.277-280
    • /
    • 2005
  • This paper dealt with the development of a surge protection device (SPD) that can protect high speed computer network devices from overvoltages caused by switching operations or lightning surges. The designed SPD is a form of hybrid circuit which is composed of a gas tube having large current diverting capability, high response bi-directional avalanche diodes, and fast recovery diodes to reduce insertion loss on high frequency domain. Surge protection and signal transmission characteristics of the fabricated SPD was tested according to the international standards, IEC 61000-4-5 and IEC 61643-21. From the test results, the SPD is satisfied with the international standards and the high cut-off frequency was 204MHz. Also, the SPD showed a good performance without an insertion loss on a field test of 100Mbps class Local Area Network

  • PDF

풍력단지의 Fault Ride-Through 기능을 위한 연계선 보호용 거리계전기의 성능향상 기법 (Improved distance relay suitable for intertie protection of a wind farm considering Fault Ride-Through requirement)

  • 강용철;강해권;정태영;이병은;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.442_443
    • /
    • 2009
  • A large wind farm should satisfy the requirements for a grid and accomplish the optimization of the wind farm system. In that point of view, the wind farm intertie protection system, which must consider the Fault Ride-Through (FRT) requirement for more reliable protection, should be improved. This paper proposes a modified distance relay suitable for protection of a wind farm intertie considering a FRT requirement. The frequency change is used to discriminate the intertie fault from a outside zone fault. The performance of the proposed algorithm is verified using a PSCAD/EMTDC simulator.

  • PDF

분산 전원의 고립 운전 진단 알고리즘 개발 (Development of a Islanding Protection Algorithm for Distributed Resources)

  • 장성일;박제영;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1287-1289
    • /
    • 2001
  • This paper presents the logic based islanding protection algorithm for distributed resources(DR) which are interconnected with distribution network. Due to the negative impacts from islanding operations of DR on protection, operation and management of distribution system, it is necessary to effectively detect the islanding operations of DR and disconnect it from distribution network rapidly. Generally, it is difficult to detect islanding operation by monitoring only one system parameter. The proposed islanding protection algorithm utilizes multi-criteria, voltage variation, phase displacement frequency variation, the variation of total harmonic distortion(THD) of current; therefore it effectively detects island operation of DR unit. We also verified the efficiency of the proposed algorithm using the radial distribution network of IEEE 34 bus model.

  • PDF

보행자 더미모델을 이용한 EURO-NCAP 상부다리모형 평가시험 방법에 대한 분석 (Upper Legform Impact Test of the EURO-NCAP Protocol using a Pedestrian Dummy Model)

  • 박상옥;최욱한;손대근;박경진;이은덕;권해붕
    • 자동차안전학회지
    • /
    • 제9권4호
    • /
    • pp.14-19
    • /
    • 2017
  • The mortality rate of car-pedestrian accidents is quite high compared to the frequency of accident. Recently, governments and insurance companies tend to establish and implement new safety standards for pedestrian protection such as EURO-NCAP and K-NCAP. The performance for the pedestrian protection has been gradually improved, but it is still insufficient. Therefore, various studies for the pedestrian protection are being carried out. The car-pedestrian accident is simulated in order to study to the upper legform test of the EURO-NCAP protocol. A pedestrian dummy model is employed and the results are discussed.

A Control and Protection Model for the Distributed Generation and Energy Storage Systems in Microgrids

  • Ballal, Makarand Sudhakar;Bhadane, Kishor V.;Moharil, Ravindra M.;Suryawanshi, Hiralal M.
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.748-759
    • /
    • 2016
  • The microgrid concept is a promising approach for injecting clean, renewable, and reliable electricity into power systems. It can operate in both the grid-connected and the islanding mode. This paper addresses the two main challenges associated with the operation of a microgrid i.e. control and protection. A control strategy for inverter based distributed generation (DG) and an energy storage system (ESS) are proposed to control both the voltage and frequency during islanding operation. The protection scheme is proposed to protect the lines, DG and ESS. Further, the control scheme and the protection scheme are coordinated to avoid nuisance tripping of the DG, ESS and loads. The feasibility of the proposed method is verified by simulation and experimental results.

소방용주파수 447 MHz와 2.4 GHz의 응답특성에 관한 연구 (A Study on the Response Characteristics of Fire Frequency 447 MHz and 2.4 GHz)

  • 오새별;김시국;지승욱;이춘하;김형권;사공성호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.31-34
    • /
    • 2011
  • 본 논문은 소방용 무선주파수로 도입 예정인 447 MHz와 2.4 GHz의 응답특성을 확인하고자, 한국소방산업기술원에서 개발된 447 MHz 무선모듈과 2.4 GHz 무선모듈을 이용하여 건축물 내에서 무선통신 환경에 영향을 줄 수 있는 대표적 장애물인 벽체를 시료로 하여 두 주파수 간의 응답특성을 비교 분석하였다. 도출된 결과를 바탕으로 향후 도입될 소방용 무선주파수 선정을 위한 기초 자료로 활용하고자 한다.

  • PDF

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.

국제표준(IEC 62305) 도입에 따른 피뢰시스템 검사 및 유지관리에 대한 연구 (A Study on a Regulation Draft of Inspection and Maintenance for Lightning Protection Facilities based on IEC 62305)

  • 이강희;이상협;구경완
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.838-844
    • /
    • 2015
  • Latest development of ICT makes building, including houses, factories and public facilities, more intelligent and automatized. It follows that a wide variety of electric and ICT installations are adopted along with micro electronic equipments. Corresponding to such changes, the frequency of lightning increases due to the abnormal climate. The major damage by lightning surge is disconnection and malfunction of facilities. It is necessary, therefore, to make a regulation of inspection and maintenance for lightning protection facilities. This paper deals with main issues of a regulation draft of inspection and maintenance for lightning protection facilities based on IEC 62305

발전기시스템의 고정자보호 IED를 위한 개선된 알고리즘 (Advanced Algorithm for IED of Stator Winding Protection of Generator System)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.91-95
    • /
    • 2008
  • The large AC generator fault may lead to large impacts or perturbations in power system. The generator protection control systems in Korea have been imported and operated through a turn-key from overseas entirely. Therefore a study of the generator protection field has in urgent need for a stable operation of the imported goods. In present, the algorithm using the current ratio differential relaying based DFT for stator winding protection or a fault detection had been applied that of internal fault protection of a generator. the DFT used for the analysis of transient state signal conventionally had defects losing a time information in the course of transforming a target signal to frequency domain. In this paper, the discrete wavelet transform (DWT) was applied a fault detection of the generator being superior to a transient state signal analysis and being easy to real time realization. The fault signals after executing a terminal fault modeling collect using a MATLAB package, and calculate the wavelet coefficients through the process of a muiti-level decomposition (MLD). The proposed algorithm for a fault detection using the Daubechies WT (wavelet transform) was executed with a C language and the commend line function for the real time realization after analyzing MATLAB's graphical interface. The advanced technique had improved faster a speed of fault discrimination than a conventional DFR based on DFT.