• Title/Summary/Keyword: Frequency and temperature

Search Result 3,825, Processing Time 0.036 seconds

Improvement of Weldlines of an Injection Molded Part with the Aid of High-Frequency Induction Heating (고주파 유도가열을 적용한 사출성형품의 웰드라인 개선)

  • Seo, Young-Soo;Son, Dong-Hwi;Park, Keun
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.437-440
    • /
    • 2009
  • High-frequency induction is an efficient way to heat mold surface by electromagnetic induction in a non-contact manner. Thanks to its capability of rapid heating and cooling of mold surface, it has been recently applied to the injection molding. The present study applies the high-frequency induction heating for elimination of weldlines in an injection-molded plastic part. To eliminate weldlines, the mold temperature of the corresponding weld locations should be maintained higher than the glass transition temperature of the resin material. Through experiments, the maximum temperature of $143^{\circ}C$ is obtained on the mold surface around the elliptic coil, while the temperature of the mold plate is lower than $60^{\circ}C$. An injection molding experiment is then performed with the aid of induction heating, and the effect of induction heating conditions on the surface appearance of the weldline is investigated.

  • PDF

A Study on the Elastic Wave Delay Line (II) (탄성파지연선에 관한 연구(II))

  • 김종상
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.2
    • /
    • pp.1-4
    • /
    • 1976
  • In this paper, temperature dependence of the resonant frequency of thickness shear mode in X cut plate of $LiN_bO_3$ is theoretically analyzed. An a result of this analysis, theoretical value -78.43${\times}10^{-5}/^{\circ}C$ of the temperature coefficient of resonant frequency is obtained.

  • PDF

A study of frequency control of an inverter heat pump for indoor air temperature adjustment (실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구)

  • Park, Yun-Cheol;Min, Man-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.

Dielectric relaxation properties in the lead scandium niobate

  • Yeon Jung Kim
    • Journal of Surface Science and Engineering
    • /
    • v.56 no.4
    • /
    • pp.227-232
    • /
    • 2023
  • In this study, complex admittance as a function of temperature and frequency was measured to analyze the important relaxation properties of lead scandium niobate, which is physically important, although it is not an environmentally friendly electrical and electronic material, including lead. Lead scandium niobate was synthesized by heat treating the solid oxide, and the conductance, susceptance and capacitance were measured as a function of temperature and frequency from the temperature dependence of the RLC circuit. The relaxation characteristics of lead scandium niobate were found to be affected by contributions such as grain size, grain boundary characteristics, space charge, and dipole arrangement. As the temperature rises, the maximum admittance and susceptance increase in one direction, but the resonance frequency decreases below the transition temperature but increases after the phase transition.

A Study on Frequency Response of GaAs MESFET with different Temperatures (온도변화에 따른 GaAs MESFET의 주파수 특성에 관한 연구)

  • 정태오;박지홍;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.550-553
    • /
    • 2001
  • In this study, unity current gain frequency f$\_$T/ of GaAs MESFET is predicted with different temperatures up to 400 $^{\circ}C$. Temperature dependence parameters of the device including intrinsic carrier concentration n$\_$i/ effective mass, depletion width are considered to be temperature dependent. Small signal parameters such as gate-source, gate dran capacitances C$\_$gs/ C$\_$gd/ are correlated with transconductance g$\_$m/ to predict the unity current gain frequency. The extrinsic capacitance which plays an important roles in high frequency region has been taken into consideration in evaluating total capacitance by using elliptic integral through the substrate. From the results, f$\_$T/ decreases as the temperature increases due to the increase of small signal capacitances and the mobility degradation. Finally the extrinsic elements of capacitances have been proved to be critical in deciding f$\_$T/ which are originated from the design rule of the device.

  • PDF

A Study on the Microwave Dielectric Properties of 0.182BaO-0.818TiOS12T Ceramics (0.182BaO-0.818TiO2 세라믹스의 마이크로파 유전특성에 관한 연구)

  • 박인길;이영희;윤석진;정형진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.442-446
    • /
    • 1994
  • In this study, microwave dielectric properties of 0.182BaO-0.818TiOS12T ceramics were investigated with sintering temperature and annealing time, and the application for the microwave dielectric resonator was studied. In the specimen simtered at 1400[$^{\circ}C$], dielectric constant, unloaded Q and temperature coefficient of resonant frequency had good values of 35.36, 5692, -4.43[ppm/$^{\circ}C$], respectively. The specimen which temperature coefficient of resonant frequency($\tau$f) was vared positive to negative value was selected, thereafter microwave dielctric properties was investigated with annealing time(0~4[hr]) in the fixed annealing temperature of 1350[$^{\circ}C$]. Increasing the annealing time, dielectric constant and unloaded Q were increased and temperature coefficient of resonant frequency was decreased.

Recent Trends of Abnormal Sea Surface Temperature Occurrence Analyzed from Buoy and Satellite Data in Waters around Korean Peninsula

  • Choi, Won-Jun;Yang, Chan-Su
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.4
    • /
    • pp.355-364
    • /
    • 2022
  • In this study a tendency of abnormal sea surface temperature (SST) occurrence in the seas around South Korea is analyzed from daily SST data from satellite and 14 buoys from August 2020 to July 2021. As thresholds 28℃ and 4℃ are used to determine marine heatwaves(MHWs) and abnormal low water temperature (ALWT), respectively, because those values are adopted by the National Institute of Fisheries Science for the breaking news of abnormal temperature. In order to calculate frequency of abnormal SST occurrence spatially by using satellite SST, research area was divided into six areas of coast and three open seas. ALWT dominantly appeared over a wide area (7,745 km2) in Gyeonggi Bay for total 94 days and it was also confirmed from buoy temperature showing an occurrence number of 47 days. MHWs tended to be high in frequency in the coastal areas of Chungcheongdo and Jeollabukdo and the south coastal areas while in case of buoy temperature Jupo was the place of high frequency (32 days). This difference was supposed to be due to the low accuracy of satellite SST at the coasts. MHWs are also dominant in offshore waters around Korean Peninsula. Although detecting abnormal SST by using satellite SST has advantage of understanding occurrence from a spatial point of view, we also need to perform detection using buoys to increase detection accuracy along the coast.

Changes in the body temperature of Proprioceptive activity by external stimulation

  • Kim, Eun-Sung;Park, Chang-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.827-831
    • /
    • 2005
  • Acupuncture and Low-frequency-wave stimulation at the Points (LI4, LI6, LI8 and LI11) on the large intestine meridian of hand resulted in same pattern about body temperature profiles with time. Upon 4Hz and 50Hz stimulation the temperature profiles on LI6 and LI11 were declined probably because of their relationship with Proprioceptive activity. Temperature different at the points was higher when the intensity of low-frequency-wave stimulation was stronger.

  • PDF

Properties of Temperature and Brightness Applied on Frequency in Electrodeless Fluorescent Lamp (무전극 형광램프의 주파수 변화에 따른 온도 및 광속 특성)

  • Lee, Joo-Ho;Choi, Gi-Seung;Kim, Nam-Goon;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.607-608
    • /
    • 2006
  • In recent, it became necessary to develop the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long lifetime. Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined temperature and flux characteristic by frequency. Considering using frequency 2.65[MHz], Frequency was changed from 2.05(MHz) to 3.05[MHz] to recognize flux and temperature change of lamp. I used LMS(Lighting Measurement System) to measure flux and IR Camera to measure temperature of lamp.

  • PDF

Properties of Temperature and Brightness Applied on Frequency in Electrodeless Fluorescent Lamp (무전극 형광램프의 주파수 변화에 따른 온도 및 광속 특성)

  • Lee, Joo-Ho;Choi, Gi-Seung;Kim, Nam-Goon;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2239-2240
    • /
    • 2006
  • In recent, it became necessary to develop the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long lifetime. Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined temperature and flux characteristic by frequency. Considering using frequency 2.65[MHz], Frequency was changed from 2.05[MHz] to 3.05[MHz] to recognize flux and temperature change of lamp. I used LMS(Lighting Measurement System) to measure flux and IR Camera to measure temperature of lamp.

  • PDF