• 제목/요약/키워드: Frequency Response Model

검색결과 1,404건 처리시간 0.025초

구조물의 결함 규명을 위한 위상최적설계 기법의 적용가능성 연구 (A Feasibility Study on the Application of the Topology Optimization Method for Structural Damage Identification)

  • 이중석;김재은;김윤영
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.115-123
    • /
    • 2006
  • A feasibility of using the topology optimization method for structural damage identification is investigated for the first time. The frequency response functions (FRFs) are assumed to be constructed by the finite element models of damaged and undamaged structures. In addition to commonly used resonances, antiresonances are employed as the damage identifying modal parameters. For the topology optimization formulation, the modal parameters of the undamaged structure are made to approach those of the damaged structure by means of the constraint equations, while the objective function is an explicit penalty function requiring clear black-and-white images. The developed formulation is especially suitable for damage identification problems dealing with many modal parameters. Although relatively simple numerical problems were considered in this investigation, the possibility of using the topology optimization method for structural damage identification is suggested through this research.

RCP 시나리오 기반 농업용 저수지의 내한능력 평가 (Assessment of Anti-Drought Capacity for Agricultural Reservoirs using RCP Scenarios)

  • 박나영;최진용;유승환;이상현
    • 한국농공학회논문집
    • /
    • 제55권3호
    • /
    • pp.13-24
    • /
    • 2013
  • Agriculture is affected directly by climate conditions and changes, and it is necessary to understand the impact of climate change on agricultural reservoirs which are the main water resources for paddy fields in Korea. This study aimed to evaluate the impact of climate change on the anti-drought capacity including water supply capability (WSC) and drought response ability (DRA) of agricultural reservoirs based on RCP (Representative Concentration Pathway) 4.5 and 8.5 scenarios of CanESM2 (The Second Generation Earth System Model) provided by CCCma (Canadian Center for Climate Modeling and Analysis). The WSC and DRA were estimated using frequency analysis and runs theory. The six reservoirs (Yooshin, Nogok, Kumsung, Songgok, Gapyung, Seoma) were selected considering geographical characteristics and design criteria of reservoir capacity. In case of Seoma reservoir, more than 10 year drought return period (DRP), the variation of the WSC was estimated larger than the others. In case of Yooshin reservior (2~5 DRP) DRC was decreased in 2025s under RCP8.5. These results could be utilized for agricultural reservoirs management and future design criteria considering climate change impacts on paddy irrigation.

이중선회 가스터빈 모델연소기에서 맥놀이 현상으로 인한 연소불안정 특성 (Combustion Instability Characteristics due to the Beating Phenomenon in the Dual Swirl Gas Turbine Model Combustor)

  • 장문석;이기만
    • 한국추진공학회지
    • /
    • 제20권6호
    • /
    • pp.61-69
    • /
    • 2016
  • 본 연구는 이중 선회 가스터빈 연소기에서 연소실 길이와 열용량을 변수로 연소불안정 현상과 관련된 결과이다. 특히 열용량이 상대적으로 작은 구간에서 연소실 길이가 길어지면 공진 주파수의 값이 일정하게 유지되는 맥놀이 현상이 발생하는 것이 확인되었다. 이러한 맥놀이 현상은 메인 화염과 파일럿 화염이 각각 다른 주기로 거동하기 때문에 발생되었으며, 연소실 길이가 증가하여도 주파수의 값이 변하지 않는 현상은 메인 화염과 파일럿 화염의 서로 다른 상호작용 결과라고 판단된다.

지하탐사 레이더의 응답 계산에 적합한 안테나 급전모델의 비교 연구 (A Comparison Study of Antenna Feed Models Suitable for Computation of Responses for a Ground-Penetrating Radar)

  • 현승엽;김세윤
    • 대한전자공학회논문지TC
    • /
    • 제38권2호
    • /
    • pp.19-27
    • /
    • 2001
  • FDTD법을 이용하여 GPR의 응답을 계산하기 위해서는 정확하고 효율적인 안테나 급전 모델이 매우 중요하다. 기존 문헌에 의하면 각주파수 영역에서 등가 회로망 모델, 시간영역에서 1차원 전송선 셀 모델, 전압경계조건 모델 등이 있다. 본 논문에서는 이러한 급전모델간의 이론적인 관계를 검토하였다. 매우 짧은 길이의 무손실 급전선이 송신기(또는 수신기) 와 정합 되었을 때 위의 3가지 모델이 서로 등가관계가 성립함을 알 수 있었다. 모의계산의 정확성과 계산의 효율성 관점에서 급전모델에 따른 실제 GPR 시스템의 수신응답 계산결과들을 비교하였다.

  • PDF

6kW 독립형 풍력발전기의 진동 모니터링 및 분석 (Vibration Monitoring and Analysis of a 6kW Wind Stand Alone Turbine Generator)

  • 김석현;남윤수;유능수;이정완;박무열;박해균;김태형
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.81-86
    • /
    • 2005
  • A vibration monitoring system for a small class of wind turbine (W/T) is established and operated. The monitoring system consists of monolithic integrated chip accelerometer for vibration monitoring, anemometers for wind data acquisition and auxiliary sensors for atmospheric data. Using the monitoring system, vibration response of a 6kW W/T generator is investigated. Acceleration data of the W/T tower under various operation condition is acquired in real time using LabVIEW and is remotely transferred from the test site to the laboratory in school by internet. Vibration state of the tower structure is diagnosed within the operating speed range. Resonance frequency range of the test model is investigated with the wind speed data of the test site.

  • PDF

Resonance and Response of the Submerged Dual Buoy/Porous-Membrane Breakwaters in Oblique Seas

  • Kee, S.T.
    • 한국해양공학회지
    • /
    • 제15권2호
    • /
    • pp.22-32
    • /
    • 2001
  • The numerical investigation of obliquely incident wave interactions with fully submerged dual buoy/porous-membrane floating breakwaters placed in parallel with spacing is studied based on linear potential theory and Darcy's law. The numerical solutions are obtained by using a discrete-membrane dynamic model and second-kind modified Bessel function distribution over the entire boundaries of fluid regions. First, numerical solutions for an idealized dual submerged system without buoys are obtained. Second, a more practical dual submerged system with membrane tension provided by buoys at its tops is investigated by the multi-domain boundary element method particularly devised for dual buoy/porous-membrane problems with gaps. The velocity potentials of wave motion are coupled with porous-membrane deformation, and solved simultaneously since the boundary condition on porous-membrane is not known in advance. The effects of varying permeability on membranes and wave characteristics are discussed for the optimum design parameters of systems previously studied. The inclusion of permeability on membrane eliminates the resonances that aggravate the breakwater performance. The system is highly efficient when waves generated by the buoys and membranes were mutually canceled and its energy at resonance frequency dissipates through fine pores on membranes.

  • PDF

병원근로자의 변화지향 조직시민행동 결정요인 : 직무만족, 조직몰입의 매개효과 검증 (Determinants of Change-Oriented Organizational Citizenship Behavior of Hospital Employees : Estimating the Mediating Effects of Job Satisfaction and Organizational Commitment)

  • 김동휘;서영준
    • 한국병원경영학회지
    • /
    • 제25권1호
    • /
    • pp.58-72
    • /
    • 2020
  • Purposes: This study aims to investigate the determinants of change-oriented organizational citizenship behavior(CO-OCB) of hospital employees and test the mediating effect of the job satisfaction and organizational commitment on the CO-OCB. Methods: Data were collected from the self-administered questionnaire survey for hospital employees of ten hospitals located in five regions, including Seoul. Out of 1,100 questionnaires which were distributed through the administrative routes, a total of 617 copies were returned(response rate 56.1%) and analyzed by frequency analysis, t-tests, correlation analysis, multiple regression, and path analysis using SPSS 21.0 and AMOS 21.0. Findings: The study results revealed that the explanatory power(56.4%) of the model was most significantly increased by the variables of psychological attributes(R2-change 33,5%). Also, the variables of self-efficacy, followed by hope, the organizational climate for innovation, the psychological safety climate, team-member exchange, and leader-member exchange were found to have positive total effects on CO-OCB, through the mediating variables of job satisfaction and organizational commitment. Practical Implications: The study results imply that, in order to improve the CO-OCB of hospital employees, the administrators have to take the integrated approach considering the various domains of factors including the psychological attributes, job characteristics, interpersonal relations, and organizational climate simultaneously.

이온 전송 및 고주파 유전 흡수 (Ion Transport and High Frequency Dielectric Absorption)

  • 윤주호;최용성;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.379-380
    • /
    • 2008
  • Molecular Dynamics (MD) simulations have been used to model the dynamics of the charge-compensating sodium ions in the non-stoichiometric hollandite Nax$(Ti_{8-x}Cr_x)O_{16}$. These interstitial ions reside in 'tunnels' in the crystal structure and move under the forces of both the ions making up the cage structure and the many body interactions of the other sodium ions in the tunnel. The Velocity Autocorrelation Function (VAF) of the sodium ions is calculated for a range of temperature from 250K to 1000K and converted into the linear ac-conductivity and ac-susceptibility response via Fourier transformation. A peak is found in the conductivity around $6\times10^{12}$ Hz that has some of the character of a Poley absorption. Here it is shown to be due to an harmonically coupled site vibrations of the sodium atoms, which extend only over a limited range. At frequencies below the peak the conductivity tends towards a constant i.e. dc value corresponding to a constant flow of ions through the simulation cell. At high temperatures the conductivity due to this ion transport process behaves like a metal with an insulator to metal transition occurring around a specific temperature.

  • PDF

옥내 전력선 통신 채널 특성 측정 (Measurement of the indoor power line channel characteristic)

  • 허윤석
    • 정보학연구
    • /
    • 제7권3호
    • /
    • pp.1-10
    • /
    • 2004
  • 옥내${\cdot}$외의 전력선 환경에 대한 정확한 채널 모델링에 관한 노력이 최근에 이루어지고 있다. 알려진 일반표준, 제한과 발표된 모델들은 특별한 형태의 접근들이였다. 본 논문에서는 더 신속하고 효율적인 전력선 통신 실험을 위한 전력선 채널 모델링에 관한 연구이다. 용량성 부하 시뮬레이터는 전력선 옥내 망 모뎀 개발에 필수적인 장비이다. 총 244 경우의 용량성 부하 변화에 대한 주파수 응답 특성 측정으로 채널 모델링을 수행하였다. 본 측정 실험에서 PLC는 일반적으로 알고 있었던 특성 보다 더 확정적인 매체라는 것을 확인하였다.

  • PDF

Robust inverse identification of piezoelectric and dielectric effective behaviors of a bonded patch to a composite plate

  • Benjeddou, Ayech;Hamdi, Mohsen;Ghanmi, Samir
    • Smart Structures and Systems
    • /
    • 제12권5호
    • /
    • pp.523-545
    • /
    • 2013
  • Piezoelectric and dielectric behaviors of a piezoceramic patch adhesively centered on a carbon composite plate are identified using a robust multi-objective optimization procedure. For this purpose, the patch piezoelectric stress coupling and blocked dielectric constants are automatically evaluated for a wide frequency range and for the different identifiable behaviors. Latters' symmetry conditions are coded in the design plans serving for response surface methodology-based sensitivity analysis and meta-modeling. The identified constants result from the measured and computed open-circuit frequencies deviations minimization by a genetic algorithm that uses meta-model estimated frequencies. Present investigations show that the bonded piezoceramic patch has effective three-dimensional (3D) orthotropic piezoelectric and dielectric behaviors. Besides, the sensitivity analysis indicates that four constants, from eight, dominate the 3D orthotropic behavior, and that the analyses can be reduced to the electromechanically coupled modes only; therefore, in this case, and if only the dominated parameters are optimized while the others keep their nominal values, the resulting piezoelectric and dielectric behaviors are found to be transverse-isotropic. These results can help designing piezoceramics smart composites for various applications like noise, vibration, shape, and health control.