• Title/Summary/Keyword: Frequency Response Method

Search Result 2,153, Processing Time 0.029 seconds

Modal Parameter Identification from Frequency Response Functions Using Legendre Polynomials (Legendre 다항식을 이용한 주파수 응답 함수의 곡선접합과 모드 매개변수 규명)

  • Park, Nam-Gyu;Jeon, Sang-Youn;Suh, Jeong-Min;Kim, Hyeong-Koo;Jang, Young-Ki;Kim, Kyu-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.769-776
    • /
    • 2006
  • A measured frequency response function can be represented as a ratio of two polynomials. A curve-fitting of frequency responses with Legendre polynomialis suggested in the paper. And the suggested curve-fitting algorithm is based on the least-square error method. Since the Legendre polynomials satisfy the orthogonality condition, the curve-fitting with the polynomials results to more reliable curve-fitting than ordinary polynomial method. Though the proposed curve-fitting with Legendre polynomials cannot cover all frequency range of interest, example shows that the suggested method is quite applicable in a limited frequency band.

Frequency Analysis Method for Linear Optically Coupled Isolation Amplifier (선형 광결합 절연 증폭기의 주파수 특성분석 기법)

  • Ahn, Hee-Wook;Sung, Young-Whee;Kim, San-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2240-2246
    • /
    • 2007
  • Optically coupled linear isolation amplifier requires special care to avoid oscillation in actual applications. In this paper methods to analyze the frequency characteristics of the amplifier are proposed to reveal the cause of oscillation and to provide design guidelines. The loop gain of the amplifier obtained through the equivalent circuit model shows that the phase margin is too small to ensure stable operations. Methods to get non-oscillatory response are proposed and the resulting frequency responses are analyzed. The common method adding a small capacitor to the amplifier is shown to degrade the frequency bandwidth. The frequency response of output voltage explains the need of filter capacitor in output stage. The usefulness of the method is verified through experiments.

Frequency Response Characteristics of Fluorescent OLED with Alternating Current Driving Method (교류구동방식에 의한 형광 OLED의 주파수 응답 특성)

  • Seo, Jung-Hyun;Ju, Sung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.1
    • /
    • pp.40-46
    • /
    • 2019
  • To study the frequency response characteristics of alternating-current-driven organic light-emitting diodes (OLEDs), we fabricated blue-fluorescent OLEDs and analyzed their electroluminescent characteristics according to the alternating current voltage and frequency. The luminance-frequency characteristics of alternating-current-driven OLED was similar to that of a low-pass filter, and the luminance of high-voltage OLED decreased at higher frequency than low-voltage OLED. The luminance characteristics of the OLED according to the frequency is due to the capacitive reactance in the OLED, generated during the alternating current driving. The frequency response characteristics of the OLED according to the voltage is due to the decrease in internal resistance of the organic layer. In addition, the negative voltage component of the alternating current did not affect the frequency response of the OLED. Therefore, the electroluminescent characteristics of OLED with an alternating current power of 60 Hz are not influenced by the frequency.

Modified complex mode superposition design response spectrum method and parameters optimization for linear seismic base-isolation structures

  • Huang, Dong-Mei;Ren, Wei-Xin;Mao, Yun
    • Earthquakes and Structures
    • /
    • v.4 no.4
    • /
    • pp.341-363
    • /
    • 2013
  • Earthquake response calculation, parametric analysis and seismic parameter optimization of base-isolated structures are some critical issues for seismic design of base-isolated structures. To calculate the earthquake responses for such non-symmetric and non-classical damping linear systems and to implement the earthquake resistant design codes, a modified complex mode superposition design response spectrum method is put forward. Furthermore, to do parameter optimization for base-isolation structures, a graphical approach is proposed by analyzing the relationship between the base shear ratio of a seismic base-isolation floor to non-seismic base-isolation one and frequency ratio-damping ratio, as well as the relationship between the seismic base-isolation floor displacement and frequency ratio-damping ratio. In addition, the influences of mode number and site classification on the seismic base-isolation structure and corresponding optimum parameters are investigated. It is demonstrated that the modified complex mode superposition design response spectrum method is more precise and more convenient to engineering applications for utilizing the damping reduction factors and the design response spectrum, and the proposed graphical approach for parameter optimization of seismic base-isolation structures is compendious and feasible.

Characteristics and Applications of a Strain Modal Testing Method (변형률 모드시험방법의 특성 및 응용)

  • 차주환;하태희;이건명
    • Journal of KSNVE
    • /
    • v.8 no.3
    • /
    • pp.420-427
    • /
    • 1998
  • A strain modal testing method has been applied to a cantilever beam to investigate the characteristics of the method. By applying the method to an analytical and an experimental system, it was shown that accurate modal parameters can be estimated from strain frequency response functions using a current modal parameter extraction algorithm. The modal parameters estimated by the method are more accurate than those by the conventional method which uses accelerometers when the tested system is of light weight. The method can be used to predict strain responses and excitation forces for given excitation forces and responses, respectively. Cracks on a structure can be detected by measuring strian FRFs and comparing them with the original ones.

  • PDF

A Study on the Compensation of Transducer Effects for the Measurement of Vibration with an Impedance Head (임피턴스헤드로 진동계측시 변환기의 부착영향을 보상하는 방법에 관한 연구)

  • 이현엽;박재영
    • Journal of KSNVE
    • /
    • v.5 no.1
    • /
    • pp.117-122
    • /
    • 1995
  • The transfer matrix method is proposed to compensate the attachment effect of a piezo-electric impedance head. To validate the proposed method, an experiment is carried out for axial vibration of a uniform rod for which an analytical solution is known. The impedance head is attached to the test rod by a stud and is connected to the exciter. The frequency response function is mesured by applying random excitation from the electro-magnetic exciter. The frequency response function compensated by the method proposed in this research shows good agreement with the analytical solution.

  • PDF

A study on natural frequency estimation of modified ship structure by using FRF synthesis method (전달함수함성법을 이용한 선박구조변경시 고유진동수 추정에 관한 연구)

  • Kim, Kuk-Su;Choi, Su-Hyun;Jo, Sung-Je
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.176-180
    • /
    • 2006
  • When the vibration troubles occur on the ship structure during the sea trial, the rectification work is very restricted because of in-situ limitation. Usually, the finite element method is used to improve vibration characteristics of the structure, but it takes lots of time and effort in modeling the structure and adjusting the finite element model in order to consider appropriate boundary conditions of a complex ship structure. Therefore, experimental methods have been in general suggested to obtain proper countermeasures without time-consuming in modeling. In this paper, FRE(frequency response function) synthesis method is applied to estimate natural frequency of the modified ship structure, which is obtained from experimental and numerical methods.

  • PDF

Simplification of Transfer Function Via Walsh Function in Frequency Domain (주파수 영역에서 Walsh 함수에 의한 전달함수의 간단화)

  • Doo-Soo Ahn
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.31 no.8
    • /
    • pp.33-38
    • /
    • 1982
  • This paper deals with the simplification of the transfer function in a frequency domain, viz. the integral of the squared errors between the original and the simplified model is minimized and the latter is estimated by the Walsh function. It tries to minimize the errors between the frequency responses of the two functions. This method is compared with the existing method by means of a numercal example. The frequency response of this simplified model approximates closely to that of the original model. The proposed method is simpler in analysis and easier in implementation than the existing methods. Though the Walsh function can be easily generated with the discrete values, it has errors because its zero crossings are not continuous. This method aims at the reduction of the errors in the real parts and the imaginary parts of the two functions by dividing into the more sub-intervals, and selecting the reduced-order model according to the response of the model. As a result, it can be applied for the simplification of higher order functions into lower order functions and for the design of control systems.

  • PDF

Preliminary Study on Linear Dynamic Response Topology Optimization Using Equivalent Static Loads (등가정하중을 사용한 선형 동적반응 위상최적설계 기초연구)

  • Jang, Hwan-Hak;Lee, Hyun-Ah;Park, Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.12
    • /
    • pp.1401-1409
    • /
    • 2009
  • All the forces in the real world act dynamically on structures. Design and analysis should be performed based on the dynamic loads for the safety of structures. Dynamic (transient or vibrational) responses have many peaks in the time domain. Topology optimization, which gives an excellent conceptual design, mainly has been performed with static loads. In topology optimization, the number of design variables is quite large and considering the peaks is fairly costly. Topology optimization in the frequency domain has been performed to consider the dynamic effects; however, it is not sufficient to fully include the dynamic characteristics. In this research, linear dynamic response topology optimization is performed in the time domain. First, the necessity of topology optimization to directly consider the dynamic loads is verified by identifying the relationship between the natural frequency of a structure and the excitation frequency. When the natural frequency of a structure is low, the dynamic characteristics (inertia effect) should be considered. The equivalent static loads (ESLs) method is proposed for linear dynamic response topology optimization. ESLs are made to generate the same response field as that from dynamic loads at each time step of dynamic response analysis. The method was originally developed for size and shape optimizations. The original method is expanded to topology optimization under dynamic loads. At each time step of dynamic analysis, ESLs are calculated and ESLs are used as the external loads in static response topology optimization. The results of topology optimization are used to update the design variables (density of finite elements) and the updated design variables are used in dynamic analysis in a cyclic manner until the convergence criteria are satisfied. The updating rules and convergence criteria in the ESLs method are newly proposed for linear dynamic response topology optimization. The proposed updating rules are the artificial material method and the element elimination method. The artificial material method updates the material property for dynamic analysis at the next cycle using the results of topology optimization. The element elimination method is proposed to remove the element which has low density when static topology optimization is finished. These proposed methods are applied to some examples. The results are discussed in comparison with conventional linear static response topology optimization.

Analysis of Transient Response of an Engine to Throttle Tip-in/Tip-out (차량 감/가속시의 엔진의 동적 응답 해석)

  • 고강호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.122-128
    • /
    • 2002
  • In this paper dynamic responses of an engine, which is supported by hydraulic mount, to throttle tip-in/Tip out are analyzed. Because the hydraulic mounts have non-linearity that the characteristics of stiffness and damping vary with frequencies, it is difficult to analyze the dynamic behavior of an engine using general integral algorithms. Convolution integral and relationship between unit impulse response functions and frequency response functions are therefore used to simulate the transient behaviors of an engine indirectly. In time domain, impulse response functions are calculated by two-side discrete inverse courier transform of frequency response function achieved by laplace transform of equations of motion. Considering the fact that the shapes of behavior of an engine simulated by the proposed method are in good agreement with test results, it is confirmed that the proposed method is very effective for the analysis of transient response to throttle tip-in/out of an engine with hydraulic mounts.