• 제목/요약/키워드: Frequency Deviation

검색결과 1,417건 처리시간 0.029초

심박변이에 대한 평가방법 (Assessing Methods of Heart Rate Variability)

  • 박기종;정희정
    • Annals of Clinical Neurophysiology
    • /
    • 제16권2호
    • /
    • pp.49-54
    • /
    • 2014
  • Heart rate variability is significantly associated with cardiovascular complications in various neurological disorders with cardiac impairment. Measures of spontaneous heart rate variability might be different from provocating tests of heart rate variability such as deep breathing and Valsava maneuver. Methods for analysis are divided into time domain methods and frequency domain methods. There are standard deviation of NN interval, standard deviation of average NN interval, root mean square of the successive differences, NN50, and pNN50 in time domain methods. Frequency domain bands can be divided into very low, low, and high frequency. Each variables are influenced by sympathetic and/or parasympathetic activity.

정궤환을 이용한 무효전력 변동기반의 단독운전 방지 성능 검증 (Performance Verification of Anti-Islanding of Reactive Power Variation Method using Positive Feedback)

  • 조종민;신창훈;차한주
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.105-110
    • /
    • 2019
  • This study proposed a reactive power variation (RPV) method equipped with positive feedback (PF) for detecting the islanding operation of distributed generation systems. The proposed RPV consists of the constant reactive power component and a certain reactive power term and uses the frequency deviation between the rated and the measured frequencies. The constant reactive power is injected from distributed generation system and power factor is to 0.9975 in grid-connected operation. PF is activated from generation of the frequency deviation and the injected reactive power is continuously increased due to PF when islanding occurs. Consequently, the increasing reactive power causes the point of common coupling frequency to deviate from the maximum/minimum threshold level. Performance of the proposed RPV is verified in a 1.7 kW T-type inverter, and the detection times are 53 and 150 ms.

A Biomolecular Sensing Platform Using RF Active System

  • Kim, Sang-Gyu;Lee, Hee-Jo;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제12권4호
    • /
    • pp.227-233
    • /
    • 2012
  • This paper describes a novel and compact biosensing platform using an RF active system. The proposed sensing system is based on the oscillation frequency deviation due to the biomolecular binding mechanism on a resonator. The impedance variation of the resonator, which is caused by a specific biomolecular interaction results in a corresponding change in the oscillation frequency of the oscillator so that this change is used for the discrimination of the biomolecular binding, along with concentration variation. Also, a Surface Acoustic Wave (SAW) filter is utilized in order to enhance the biosensing performance of our system. Because the oscillator operates at the skirt frequency range of the SAW filter, a small amount of oscillation frequency deviation is transformed into a large variation in the output amplitude. Next, a power detector is used to detect the amplitude variation and convert it to DC voltage. It was also found that the frequency response of the biosensing system changes linearly with three streptavidin concentrations. Therefore, we expect that the proposed RF biosensing system can be applied to bio/medical applications capable of detecting a nano-sized biomolecular interaction.

회전자 속도에 따라 변하는 게인에 기반한 가변속 풍력발전기 출력 평활화 (Power Smoothing of a Variable-Speed Wind Turbine Generator Based on the Rotor Speed-Dependent Gain)

  • 김연희;강용철
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.533-538
    • /
    • 2016
  • In a power grid that has a high penetration of wind power, the highly-fluctuating output power of wind turbine generators (WTGs) adversely impacts the power quality in terms of the system frequency. This paper proposes a power smoothing scheme of a variable-speed WTG that can smooth its fluctuating output power caused by varying wind speeds, thereby improving system frequency regulation. To achieve this, an additional loop relying on the frequency deviation that operates in association with the maximum power point tracking control loop, is proposed; its control gain is modified with the rotor speed. For a low rotor speed, to ensure the stable operation of a WTG, the gain is set to be proportional to the square of the rotor speed. For a high rotor speed, to improve the power smoothing capability, the control gain is set to be proportional to the cube of the rotor speed. The performance of the proposed scheme is investigated under varying wind speeds for the IEEE 14-bus system using an EMTP-RV simulator. The simulation results indicate that the proposed scheme can mitigate the output power fluctuation of WTGs caused by varying wind speeds by adjusting the control gain depending on the rotor speed, thereby supporting system frequency regulation.

수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안 (Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-Horizontal Area Ratio)

  • 우성식;이상현;정란;이정우;조승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.653-658
    • /
    • 2008
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the Case01 to 19, the standard deviation($s_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the Case21 to 61, the standard deviation ($s_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF

수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안 (Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-horizontal Area Ratio)

  • 우성식;정란;이정우
    • 한국소음진동공학회논문집
    • /
    • 제19권2호
    • /
    • pp.119-126
    • /
    • 2009
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the case01 to 19, the standard deviation($S_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the case21 to 61, the standard deviation($S_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

위성통신대역 주파수 공유를 위한 AltBOC 상관 내 주변 첨두 제거 기법 (Cancellation of AltBOC Correlation Side-Peaks for Frequency Sharing in Satellite Communication Spectrum)

  • 채근홍;윤석호
    • 한국통신학회논문지
    • /
    • 제39B권11호
    • /
    • pp.810-816
    • /
    • 2014
  • Alternative binary offset carrier (AltBOC) 신호는 기존의 phase shift keying (PSK) 신호와 주파수 대역을 공유한다는 특성을 지니고 있기에, 효율적으로 주파수 대역을 이용할 수 있다는 장점이 있으나, AltBOC 신호의 자기상관함수에 존재하는 주변 첨두로 (side-peak) 인해 AltBOC 신호의 주파수 공유 특성을 효과적으로 이용할 수 없다는 단점이 존재한다. 따라서 본 논문에서는 AltBOC 신호의 주파수 공유 특성을 극대화하고자 자기상관함수에 존재하는 주변 첨두 제거 기법을 제안한다. 모의실험을 통해 제안한 기법을 이용하여 신호 추적을 수행할 경우, 주변 첨두 제거 효과에 의해 기존 자기상관함수를 이용하는 기법에 비해 향상된 추적 오류 표준편차를 (tracking error standard deviation: TESD) 보이고, 이에 따라 AltBOC 신호의 주파수 공유 특성을 효과적으로 이용할 수 있음을 보인다.

1/f 수준 별 음악 자극이 감정 노동 종사자의 심장 반응에 미치는 효과 (Heart Response Effect by 1/f Fluctuation Sounds for Emotional Labor on Employee)

  • 전병무;황민철
    • 감성과학
    • /
    • 제18권3호
    • /
    • pp.63-70
    • /
    • 2015
  • 본 연구는 1/f fluctuation의 ${\alpha}$기울기 따라 구성된 사운드를 들었을 때 감정 스트레스 업무에 종사하고 있는 피험자들의 심박 변화를 확인하고자 하였다. 기존의 연구에서는 주로 사용자의 심리상태 안정시키는 효과 또는 생리적 안정성에 1/f fluctuation의 ${\alpha}$기울기가 관계가 있는 것으로 보고되었다. 본 연구에서는 1/f fluctuation 수준을 총 3가지 나누어 제작한 사운드를 독립변수로 사용하였다. 독립변수는 감정노동 종사자에게 제시하여 그에 따른 심장반응을 측정하였다. 종속변수는 네 가지로 BPM(Beat Per Minute), VLF(Very Low Frequency), SDNN(Standard Deviation of NN intervals), 그리고 HF(High Frequency) 파워(Power)값을 확인하였다. 분석결과 기울기가 3인 1/fluctuation 사운드는 각성효과를 보였다. 기울기 1, 2인 사운드는 이완효과가 있는 것을 통계적으로 검증하였다. 이러한 1/f fluctuation 사운드의 특성을 활용해 감정 노동자들의 스트레스를 완화시키기 위한 서비스에 응용될 수 있을 것으로 사료된다.

VIBRATION OF A CIRCULAR PLATE WITH A CONCENTRATED MASS ATTACHED ON A RADIUS

  • Lee, Jang-Moo;Hong, Jin-Sun
    • Journal of Theoretical and Applied Mechanics
    • /
    • 제1권1호
    • /
    • pp.89-96
    • /
    • 1995
  • An analytical method is presented for predicting the effect of a local deviation in the form of a concentrated mass along a radial line on the free bending vibration characteristics of a nearly axisymmetric circular plate. The approach is based on the Rayleigh-Ritz method and the expression of local deviation of the concentrated radial mass as the variation of heaviside unit step function. The effects of the concentrated mass on the natural frequencies and mode shapes of the plate are predicted with a proposed nondimensional mass parameter.

부하 편차 방식의 전신진동운동이 하지 근력 불균형 개선에 미치는 효과 (The Effect on Improvement of Muscle Strength Imbalance According to Load Deviation Protocol of Whole Body Vibration Exercise)

  • 서신배;강승록;유창호;민진영;권대규
    • 한국정밀공학회지
    • /
    • 제30권10호
    • /
    • pp.1095-1101
    • /
    • 2013
  • The purpose of this study was to verify the effect on improvement of muscle strength unbalance according to load deviation protocol during whole body vibration exercise. Seventeen female volunteers (age $22{\pm}3$ years, height $160{\pm}4.9$ cm, weight $49{\pm}.8$ kg) participated in this experiment. The subjects performed squat exercise in WBV platform. Exercise were performed five set a day including 15 time a set, three days a week, and during 4 weeks. Vibration stimulus was 25Hz as frequency and intensity was dominant leg 1mm and non-dominant leg 4mm. The results in WBV group showed that the differences of peak torque in 16% were getting decreasing significantly after 4 weeks from 16.2% to 5.2%. This result means that WBV with load deviation protocol could provide muscle strength exercise for muscle strength balance. Our study found out that WBV of load deviation protocol could provide muscle strength exercise for improving muscle imbalance.