• 제목/요약/키워드: Frequency Control

검색결과 8,917건 처리시간 0.033초

계통연계형 마이크로그리드의 독립운전시 주파수 제어에 관한 연구 (Frequency Control Method of Grid Interconnected Microgrid Operating in Stand Alone Mode)

  • 채우규;이학주;박중성;조진태;원동준
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1099-1106
    • /
    • 2012
  • Microgrid is a new electrical energy system that composed of various generators, renewable energy, batteries and loads located near the electrical customers. When Microgrid is interconnected with large power system, Microgrid don't need to control the frequency. But in case of the outage or faults of power system, Microgrid should control the frequency to prevent the shutdown of Microgrid. This paper presents the frequency control methods using the droop function, being used by synchronous generators and EMS(Energy Management System). Using droop function, two battery systems could share the load based on locally measured signals without any communications between batteries. Also, we suggest that EMS should control the controllable distributed generators as P/Q control modes except batteries to overcome the weakness of droop function. Finally we suggest the two batteries systems to prolong the battery's life time considering the economical view. The validation of proposed methods is tested using PSCAD/EMTDC simulations and field test sites at the same time.

초음파 모터 구동을 위한 단순화된 디지털 주파수/위상차/전압 제어기 (A Simplified Digital Frequency/Phase/Voltage Controller for the Traveling Wave Type Ultrasonic Motor Drive System)

  • 이을재;김영석
    • 전력전자학회논문지
    • /
    • 제4권3호
    • /
    • pp.285-293
    • /
    • 1999
  • 본 논문에서는 인버터를 사용하여 진행파형 초음파 모터를 구동할 때에 구동 주파수, 위상차 및 상간의 전압을 제어하기 위해 새로운 방식의 초음파 모터 구동용 디지털 제어기를 제안하였다. 제안된 디지털 제어기는 주파수 발생과 위상차 제어를 하기 위하여 기존의 제어기에서 사용한 디지털-아날로그 혼합 방식이 아닌 디지털 논리에 의하여 출력이 발생되며 이로 인하여 제어기의 구성이 대폭 단순해진 특징을 갖는다. 제안된 디지털 제어기는 두 가지 형태로 주파수와 위상만을 제어하기 위한 경우와 상간의 전압까지 제어하기 위한 경우로 분리하였다. 실험에서는 상용 LSI와 EPLD를 사용하여 구현된 단순화된 디지털 제어기의 성능을 평가하였다.

  • PDF

퍼지 알고리즘을 이용한 유도전동기 간접벡터제어기의 설계와 엘리베이터 속도제어 시스템의 응용 (Design of Indirect Vector Controller of Induction Motor using Fuzzy Algorithm and apply to the Speed Control System of Elevator)

  • 경제문;김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.110-113
    • /
    • 2000
  • In general, speed control method of the elevator system has used motor pole change type or motor primary voltage control type. But it will change to vector control type in order to increase it's reliability, riding comfort and decrease material cost. It is the conception of vector control type in order to increase it's reliability, riding comfort and decrease material cost. It is the conception of vector control that primary current of the induction motor be controlled independently with magnetizing current(field current of DC motor) and torque current(armature current of DC motor). In this paper, by analyzing the effect of the time constant variation of rotor of the induction motor on the slip frequency type indirect vector control, a drive system for the motor will be constructed using a fuzzy slip frequency type indirect vector controller with fuzzy control method for estimating the vector time constant in the slip frequency type indirect vector control. The goal of this study is to enabling even more efficient speed control by constructing on elevator driver based on the newly developed drive system.

  • PDF

주파수 의존형 최적 레귤이터에 의한 크레인 흔들림 제어계 설계 (Swing Motion Control System Design Based on Frequency-shaped LQ Control)

  • 김영복;장지성
    • 동력기계공학회지
    • /
    • 제12권6호
    • /
    • pp.50-55
    • /
    • 2008
  • In general, the swing motion of the crane is controlled and suppressed by activating the trolley motion. In many papers reported by us, we suggested a new type of anti-sway control system of the crane. In the proposed control system, a small auxiliary mass(moving-mass) is installed on the spreader and the swing motion is controlled by moving the auxiliary mass. The actuator reaction against the auxiliary mass applies inertial control forces to the container in order to reduce the swing motion in the desired manner. Futhermore the measuring systems based on image sensor have been proposed also. To obtain the robustness for our control system, $H_{\infty}$ based control techniques and other approach have been applied to suppress swing motion. As well known, the robust control technologies based on $H_{\infty}$ control need complicated and difficult process. In the result, the obtained closed-loop system becomes to high order system which may give us many difficulties to apply it to the real plants. Therefore, we introduce an easy approach which is based on LQ control theory. In this approach, we introduce the frequency dependent weighting matrices which give the system filters to shape frequency characteristics of the controlled system and guarantee the control performance.

  • PDF

가변구조제어 이론을 이용한 유도 서보 전동기의 위치제어 (Position Control for Induction Servo Motors Using a Theory of Variable Structure Control)

  • 홍순일;홍정표
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.132-139
    • /
    • 2005
  • This paper describes the application of sliding mode control based on the variable structure control(VSC) concept for high-performance position control of an induction servo motor A design method based on external load parameters has been developed for the robust control of AC induction servo drive. Also, a slip frequency vector control with software current control technique has been adopted to achieve fast response of an induction motor drive The position control scheme is comprised of a variable structure controller and slip frequency vector control for inverter fed induction servo motor. Simulated results are given to verify the proposed design method by adoption of sliding mode and show robust control for a change of shaft inertia, viscous friction and torque disturbance.

제동 시스템을 위한 고주파수 ECU의 제어 특성 연구 (Study on the Characteristics of Control by High Frequency ECU for Braking System)

  • 연규봉;정정화
    • 한국산학기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.2428-2434
    • /
    • 2012
  • 본 논문은 제동 시스템에서 전자식 주행안정 제어장치(ESC)의 유압 모듈레이터의 솔레노이드 밸브 제어에 대한 것이다. ESC의 전자제어유니트(ECU)를 제어하기 위한 방법으로 고주파수 제어와 슬로프 제어를 적용하였으며, 서지 압력 및 전자파간섭(EMI) 저감 특성을 연구하였다. 고주파수에서의 전자파 방출을 줄이기 위하여 ECU 출력 단에 슬로프 제어 기능을 추가하였다. 측정결과 제동 시스템에서 고주파수 ECU의 솔레노이드 밸브제어 방법에 따라 서지 압력과 전자파 방출이 저감될 수 있음을 확인하였다. 결론적으로 고주파수 ECU 제어 연구 결과에 의해 제동 시스템 성능을 향상방안을 제시하고자 한다.

비디오 카세트 레코더의 자동 주파수 조절의 디지탈 신호처리 (Digital signal processing of automatic frequency control is VCR)

  • 김동하;이태원
    • 전자공학회논문지B
    • /
    • 제33B권6호
    • /
    • pp.128-135
    • /
    • 1996
  • In this paper, a digital signal processing method of AFC (automatic frequency control) is proposed for a home use VCR system. The proposed method has the ability of frequency tracking of a wide range. Implemented with digital circuits, the system is to be used in a digital video system and saves the cost of a hardware compared with a conventional analog automatic frequency control method using several PLL's in case of making home use VCR systems compatible with several TV systems.

  • PDF

Frequency-Domain Balanced Stochastic Truncation for Continuous and Discrete Time Systems

  • Shaker, Hamid Reza
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권2호
    • /
    • pp.180-185
    • /
    • 2008
  • A new method for relative error continuous and discrete time model order reduction is proposed. The reduction technique is based on two recently developed methods, namely frequency domain balanced truncation within a frequency bound and inner-outer factorization techniques. The proposed method is of interest for practical model order reduction because in this context it shows to keep the accuracy of the approximation as high as possible without sacrificing the computational efficiency. Numerical results show the accuracy and efficiency enhancement of the method.

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF

전력계통 주파수응답 기여도 기반의 전기저장장치 주파수추종서비스 유효용량 산정 (Effective Capacity Calculation of the Electrical Energy Storage providing the Primary Frequency Control Service based on the Contribution to the Frequency Response of Power Systems)

  • 임현옥;최우영;권한나;국경수
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1561-1567
    • /
    • 2017
  • This paper calculates the effective capacity of EES providing the primary frequency control service based on its contribution to the frequency response of the power system. The amount of governor response from conventional generators which can be replaced by the primary frequency control from EES keeping the frequency response of the power system is defined as the effective capacity. The proposed method for calculating the effective capacity of EES is verified through case studies employing Korean power system. Furthermore, the application of the effective capacity of EES to power system operation is also discussed.