• Title/Summary/Keyword: Frequency Component

Search Result 1,816, Processing Time 0.036 seconds

Distance Relaying Algorithm Using a DFT-based Modified Phasor Estimation Method (DFT 기반의 개선된 페이저 연산 기법을 적용한 거리계전 알고리즘)

  • Lee, Dong-Gyu;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1360-1365
    • /
    • 2010
  • In this paper, we propose a distance relaying algorithm using a Discrete Fourier Transform (DFT)-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Most distance relays are based on estimating phasors of the voltage and current signals. A DFT is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. For this reason, distance relays have a tendency to over-reach or under-reach in the presence of DC offset components in a fault current. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. The error due to DC offsets in a DFT is calculated and eliminated using the outputs of an even-sample-set DFT and an odd-sample-set DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated for a-phase to ground faults on a 345 kV, 50 km, simple overhead transmission line. The Electromagnetic Transient Program (EMTP) is used to generate fault signals. The evaluation results indicate that adopting the proposed algorithm in distance relays can effectively suppress the adverse influence of DC offsets.

Phasor Estimation Method Eliminating the Effect of the DC offsets (DC 옵셋의 영향을 제거한 페이저 연산 기법)

  • Lee, Dong-Gyu;Kim, Hyung-Kyu;Kwon, Young-Jin;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.203_204
    • /
    • 2009
  • In this paper, we propose a Fourier transform-based modified phasor estimation method to eliminate the adverse influence of exponentially decaying DC offsets. Discrete Fourier Transform (DFT) is generally used to calculate the phasor of the fundamental frequency component in digital protective relays. However, the output of the DFT contains an error due to exponentially decaying DC offsets. Therefore, the decaying DC components should be taken into consideration when calculating the phasor of the fundamental frequency component of a relaying signal. In this paper, the error due to DC offsets in a DFT is calculated and eliminated using the outputs of quaternity DFT, so that the phasor of the fundamental component can be accurately estimated. The performance of the proposed algorithm is evaluated by using computer-simulated signals and EMTP-generated signals. A performance evaluation showed that the proposed algorithm was not affected by system and fault conditions. Thus, the proposed algorithm can effectively suppress the adverse influence of DC offsets in a relaying signal.

  • PDF

A study on "complex demodulation" for autonomic nerve system analysis (자율신경계 기능 평가를 위한 complex demodulation에 관한 연구)

  • Kim, Han-Soo;Lee, Jeong-Whan;Lee, Joon-Young;Lee, Dong-Joon;Seo, Hyun-Woo;Lee, Myung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.994-996
    • /
    • 1999
  • In this paper, we proposed complex demodulation method(CDM) to visualize the instantaneous frequency change of LF component and HF component of HRV signals, which represent the dynamics of sympathetic and parasympathetic (vagal) tone, respectively. As we know the range of the center frequencies of each autonomic tones, we could apply complex demodulation method. To simulate the heart rate variability signal, the IFPM model was adopted for generation of simulated cardiac event series. Then, we can visualize and access the dynamic changes of LF and HF component of autonomic tones in the time-frequency domain.

  • PDF

Comparative Anatomy of Diffuse-Porous Woods Grown in Korea (I) -Characteristics by Simple Correlation and Principal Component Analysis- (한국산(韓國産) 산공재(散孔材)의 해부학적(解剖學的) 특성(特性)에 관한 비교연구(比較硏究)(I) -단순상관(單純相關)과 주성분(主成分) 분석(分析)에 의한 특성(特性)-)

  • Chung, Youn-Jib;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.46-53
    • /
    • 1995
  • The anatomy of Korean diffuse-porous woods, 36 families, 75 genera, 145 species, 215 specimens was described and analyzed. Sixteen wood anatomical characters, habit and phenology factors were determined by simple correlation and principal component analysis. Strong positive correlations were found between vessel element length and fiber length, ray width and ray height, simple pits of fiber wall and paratracheal parenchyma distribution. The results of principal component analysis (PCA) disclose the primitive characteristics and the direction of xylem evolution of Korean diffuse-porous woods. The xylem evolution scenario for Korean dicotyledonous woods is considered to be developed in the direction of decreasing trends of vessel frequency, vessel element length, and length/diameter(L/D) ratio of vessel element but increasing trends of vessel diameter, fiber length/vessel element length(F/V) ratio, libriform wood fibers, simple perforation, and homogeneous ray composition. Increase of vessel diameter and decrease of vessel frequency seem to be related to the improvement of conductive efficiency, and increase of the vessel element length and occurrence of scalariform perforation in vessel element may be related to enhanced of conductive safety. Also the libriform wood fibers and ray features appear to have relationship with mechanical support and nutrient metabolism, respectively.

  • PDF

A DFT Based Filtering Technique to Eliminate Decaying dc and Harmonics for Power System Phasor Estimation

  • Oh Yong- Taek;Balamourougan V.;Sidhu T.S.
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.138-143
    • /
    • 2005
  • During faults, the voltage and current signals available to the relay are affected by the decaying dc component and harmonics. In order to make appropriate and accurate decisions, most of the relaying algorithms require the fundamental frequency phasor information that is immune to decaying dc effect and harmonics. The conventional Fourier ph as or estimation algorithm is affected by the presence of decaying-exponential transients in the fault signal. This paper presents a modified Fourier algorithm, which effectively eliminates the decaying dc component and the harmonics present in the fault signal. The decaying dc parameters are estimated by means of an out-of-band filtering technique. The decaying dc offset and harmonics are removed by means of a simple computational procedure that involves the design of two sets of Orthogonal digital OFT filters tuned at different frequencies and by creating three off-line look-up tables. The technique was tested for different decay rates of the decaying dc component. It was also compared with the conventional mimic plus the full cycle OFT algorithm. The results indicate that the proposed technique has a faster convergence to the desired value compared to the conventional mimic plus OFT algorithms over a wide range of decay rates. In all cases, the convergence to the desired value was achieved within one cycle of the power system frequency.

A Study on Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-phase Grid-connected Inverters (단상 계통연계형 인버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구)

  • Hwang, Seon-Hwan;Hwang, Young-Gi;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.68-76
    • /
    • 2014
  • This paper presents an offset error compensation algorithm for the accurate phase angle of the grid voltage in single-phase grid-connected inverters. The offset error generated from the grid voltage measurement process cause the fundamental harmonic component with grid frequency in the synchronous reference frame phase lock loop (PLL). As a result, the grid angle is distorted and the power quality in power systems is degraded. In addition, the dq-axis currents in the synchronous reference frame and phase current have the dc component, first and second order ripples compared with the grid frequency under the distorted grid angle. In this paper, the effects of the offset and scaling errors are analyzed based on the synchronous reference frame PLL. Particularly, the offset error can be estimated from the integrator output of the synchronous reference frame PLL and compensated by using proportional-integral controller. Moreover, the RMS (Root Mean Square) function is proposed to detect the offset error component. The effectiveness of the proposed algorithm is verified through simulation and experiment results.

A Single-stage Interleaved Electrolytic Capacitor-less EV Charger with Reduced Component Count (전해커패시터가 없고 적은 소자수를 갖는 단일단 인터리브드 전기자동차용 충전기)

  • Kim, Min-Jae;Kim, Byeong-Woo;Jung, Bum-Kyo;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.185-192
    • /
    • 2017
  • This paper proposes a single-stage interleaved soft-switching electrolytic capacitor-less EV charger with reduced component count and simple circuit structure. The proposed charger achieves ZVS turn-on of all switches and ZCS turn-off of all diodes without regard to voltage and load variation. It achieves high power density even without an input filter due to CCM operation and bulky electrolytic capacitors and without a low-frequency component in the transformer. A 2 kW prototype of the proposed charger with sinusoidal charging is built and tested to verify the validity of the proposed operation.

An Introduction to Energy-Based Blind Separating Algorithm for Speech Signals

  • Mahdikhani, Mahdi;Kahaei, Mohammad Hossein
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.175-178
    • /
    • 2014
  • We introduce the Energy-Based Blind Separating (EBS) algorithm for extremely fast separation of mixed speech signals without loss of quality, which is performed in two stages: iterative-form separation and closed-form separation. This algorithm significantly improves the separation speed simply due to incorporating only some specific frequency bins into computations. Simulation results show that, on average, the proposed algorithm is 43 times faster than the independent component analysis (ICA) for speech signals, while preserving the separation quality. Also, it outperforms the fast independent component analysis (FastICA), the joint approximate diagonalization of eigenmatrices (JADE), and the second-order blind identification (SOBI) algorithm in terms of separation quality.

3 Directional Vibration Measurement of Wide Face Width Helical Gears (광치폭 헬리컬 기어의 3 방향 진동 측정)

  • Park, Chan-Il;Cho, Do-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.661-666
    • /
    • 2004
  • The purpose of this study is to measure the rotational vibration, radial vibration, and axial vibration for the helical gear with the wide face width relative to the whole depth. For this purpose, the experimental apparatus is designed and manufactured. The gear vibration of each direction is measured by the accelerometers attached at the gear body. As a result, meshing frequency and second harmonic component are greatly contributed to the gear vibration. As the rotational speed is increased, meshing frequency component has the more significant peak than the second harmonic one. However, the doubled torque decreases the vibration magnitude on the contrary and changes order of the vibration magnitude in each direction.

  • PDF

In DCT,Image Data Compression via Directional Zonal Filters (DCT 변환상에서 방향성 Zonal 필터를 이용한 화상 데이터 압축)

  • 정동범;김해수;조승환;이근영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.2
    • /
    • pp.172-179
    • /
    • 1991
  • In this paper we have proposed an efficient coding algorithm using directional filtering. First an image is transformed by using DCT which has better energy compaction and then the transformed image is divided into a low frequency component and several high frequency components. The transformed coefficients of each parts are transmitted respectively by using huffman code and these are transformed inversely at receiver. For the directional components total edge images are reconstructed at zero crossing points. We are able to reduce the amount of data by getting of complex component and making directional angles 90. As a results, this proposed method is better than that of Kunt in respect of processing time and memories. We have 38dB of image quality with objective measurement of PSNR and 0.26bpp of compression ratio which is acceptable.

  • PDF