• Title/Summary/Keyword: Frequency Compensation

Search Result 862, Processing Time 0.03 seconds

Research about muscle ache curer design development for hospital (병원용 근육통증 치료기 디자인 개발에 관한 연구)

  • Oh, Sung-Jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.11a
    • /
    • pp.856-859
    • /
    • 2006
  • Patient's position who muscle ache curer for hospital undergoes person entrance and treatment that take advantage of biological, physical force of low frequency and it is equipment that treat body muscle ache, but use equipment when use patient into compensation in hospital specially, that consider everybody is important first of all. This research question investigation with market survey of old product enforce because preference degree reflected officer a result and apply opinion tuned with product development connection engineers on DESIGN direction via typical product design development process close. This curer development research analyzed data involved directly taking advantage of FGI techniques with literature investigation collection. Investigation examined laying stress on muscle ache curer for hospital and a nurse than a doctor answered on question and purchase selection criterion or price portion to user focus. Direct market survey research that see item indicated by competition four provision shortcomings consequently in NEW MODEL development hereafter supplement and expectation. by contributing greatly in M/S security strategy hereafter because design development consisted for side that improve.

  • PDF

A Novel Method for Calculating the Stroke of LPMSM for Driving Linear Compressor Using High Pass Filter (고역필터를 사용한 선형압축기 구동용 LPMSM의 새로운 스트로크 계산 기법)

  • Ahn, Jung-Ryol;Lee, Hong-Hee;Kim, Heung-Gun;Nho, Eui-Cheol;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • Linear compressors with a free piston driven by a linear motor are widely attention in the cooling apparatus such as refrigerator due to the high efficiency The stroke of piston in the linear compressor driven by LPMSM (Linear Permanent-Magnet Synchronous Motor) can be obtained from Integrating the input voltage and current of LPMSM, but it may be diverged due to dc components in the voltage and current. The strategy to prevent the divergence of stroke using both the high-pass filter and do offset compensation was suggested. The equations for the magnitude and phase of the stroke and also dc offset including the stroke are derived as a function of the cut-off frequency of HPF. The accurate stroke of a piston can be calculated by compensating for dc offset. The performance of the newly developed stroke calculation scheme has been verified by experimentally on a linear compressor drive system, where the control was implemented by a 16-bit DSP.

Study of RF Impairments in Wideband Chirp Signal Generator (광대역 첩 신호 발생기를 위한 RF 불균형 연구)

  • Ryu, Sang-Burm;Kim, Joong-Pyo;Yang, Jeong-Hwan;Won, Young-Jin;Lee, Sang-Kon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1205-1214
    • /
    • 2013
  • Recently spaceborne SAR systems are increasing image resolution and frequency. As a high quality image resolution, the wider bandwidth is required and a wideband signal generator with RF component is very complicated and RF impairments of device is increased. Therefore, it is very important to improve performance by reducing these errors. In this study, the transmission signal of the wideband signal generator is applied to the phase noise, IQ imbalance, ripple gain, nonlinear model of high power amplifier. And we define possible structures of wideband signal generator and measure the PSLR and ISLR for the performance assesment. Also, we extract error of the amplitude and phase from the waveform and use a quadratic polynomial curve fitting and examine the performance change due to nonlinear device. Finally, we apply a high power amplifier predistortion method for non-linear error compensation. And we confirm that distortion in the output of the amplifier by intermodulation component is decreased by 15 dB.

Nitrogen Wash-Out Technique to Measure Functional Residual Capacity Based on Expired o2/Co2 Analysis (o2/Co2 분석기를 사용하여 폐의 기능적 잔기용량을 계측하는 질소세척법 개발)

  • Kim, Goon-Jin;Kim, Kyung-Ah;Lee, Jae-Hun;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • Functional residual capacity (FRC) is an important diagnostic parameter measured using $N_{2}$ analyzer. Since $N_{2}$ analyzer is expensive as well as cumbersome for use of noisy vacuum pump, the FRC measurement becomes possible only in large well-equipped hospitals. The present study introduced a new $TN_{2}$ wash-out technique to measure FRC by $O_{2}/CO_{2}$ analysis, which is relatively cheaper and much simpler to apply. Slower $O_{2}$ response was compensated for high frequency to be coincided with $CO_{2}$ response, thereby enabled indirect, but accurate $N_{2}$ concentration measurement. FRC was estimated by continuous integration of expired $N_{2}$ volume obtained with air flow signal. Experiment with 3 L syringe, a standard calibration device recommended by the American Thoracic Society, demonstrated less than 1% error at 0, 1, and 2 L. Correlation coefficient was almost ideal, guaranteeing linear estimation of FRC. The present technique is inexpensive and simple to apply, thus should he of great convenience.

Embedded Compression Codec Algorithm for Motion Compensated Wavelet Video Coding System (움직임 보상된 웨이블릿 기반의 비디오 코딩 시스템에 적용 가능한 임베디드 압축 코덱 알고리즘)

  • Kim, Song-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.77-83
    • /
    • 2012
  • In this paper, a low-complexity embedded compression (EC) Codec algorithm for the wavelet video coder is applied to reduce excessive external memory requirements. The EC algorithm is used to achieve a fixed compression ratio of 50 % under the near-lossless-compression constraint. The EC technique can reduce the 50 % memory requirement for intermediate low-frequency coefficients during multiple discrete wavelet transform stages compared with direct implementation of the wavelet video encoder of this paper. Furthermore, the EC scheme based on a forward adaptive quantization and fixed length coding can save bandwidth and size of buffer between DWT and SPIHT to 50 %. Simulation results show that our EC algorithm present only PSNR degradation of 0.179 and 0.162 dB in average when the target bit-rate of the video coder are 1 and 0.5 bpp, respectively.

A Design of Low-Error Truncated Booth Multiplier for Low-Power DSP Applications (저전력 디지털 신호처리 응용을 위한 작은 오차를 갖는 절사형 Booth 승산기 설계)

  • 정해현;박종화;신경욱
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.2
    • /
    • pp.323-329
    • /
    • 2002
  • This paper describes an efficient error-compensation technique for designing a low-error truncated Booth multiplier which produces an N-bit output from a two's complement multiplication of two N bit inputs by eliminating the N least-significant bits. Applying the proposed method, a truncated Booth multiplier for area-efficient and low-power applications has been designed, and its performance(truncation error, area) was analyzed. Since the truncated Booth multiplier does not have about half the partial product generators and adders, it results an area reduction of about 35%, compared with no-truncated parallel multipliers. Error analysis shows that the proposed approach reduces the average truncation error by approximately 60%, compared with conventional methods. A 16-b$\times$16-b truncated Booth multiplier core is designed on full-custom style using 0.35-${\mu}{\textrm}{m}$ CMOS technology. It has 3,000 transistors on an area of 330-${\mu}{\textrm}{m}$$\times$262-${\mu}{\textrm}{m}$ and 20-㎽ power dissipation at 3.3-V supply with 200-MHz operating frequency.

A Study of Job Stress and Job Satisfaction of Medical Aid Client Managers (의료급여관리사의 직무스트레스와 직무만족도)

  • Choi, Jeong Myung;Oh, Jin Joo;Lee, Hyun Joo
    • Korean Journal of Occupational Health Nursing
    • /
    • v.17 no.2
    • /
    • pp.146-154
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the degree of job stress and job satisfaction and the relationship between job stress and job satisfaction of Medical Aid Client Managers. Method: Data were collected from 185 Medical Aid Client Managers in 234 areas between April 2-15, 2007. Collected data was analyzed for the frequency, t-test, ANOVA, Pearson's Correlation Coefficient etc. Results: The average score of job stress was 2.6. Job instability was highest as 2.9 and job autonomy was lowest as 2.2. in eight items. When the job stress of Medical Aid Client Managers was converted to 100 point, the average was 51.7 and ranked in upper 50% of Korean woman workers' job stress. Among the eight items, because the relationship satisfaction and the instability of duty regime ranked in upper 25% of Korean woman workers' job stress, those items were identified to have high stress. The average score of job satisfaction was 2.3 out 4.0 which could be interpreted as unsatisfactory. The correlation between the job stress and the job satisfaction demonstrated significant difference. Decrease of the job satisfaction was associated with increase of the job stress. In regard to the eight items, the inverse correlation was demonstrated to be significant in organization, inappropriate compensation, and workplace culture. Conclusion: Medical Aid Client Managers have high stress in carrying out their duties. They have experienced very severe instability in their duty regime. Also, they have felt alienated from their organization and experienced unfair rewards. They had low duty satisfaction but got a heavy workload and experienced overtime work. To relieve job overburden of Medical Aid Client Managers. it was necessary to improve business system and also was necessary to relieve a regional disparity of business charge.

  • PDF

Transformation of Stereoscopic Images for 3D Perception Improvement (입체영상의 3D 증강을 위한 입체영상 변환)

  • Gil, Jong In;Choi, Hwang Kyu;Kim, Manbae
    • Journal of Broadcast Engineering
    • /
    • v.17 no.6
    • /
    • pp.911-923
    • /
    • 2012
  • Recently, 3DTV and 3D displays have been released in the market. Accordingly, the production of stereoscopic images has gained much interest. Stereoscopic image being composed of left and right images are currently delivered to viewers without any modifications. The researches on the enhancement of depth perception using high-frequency components and the re-production of natural color by color compensation have been carried out for 2D images. The application of such 2D technologies to 3D stereoscopic images is an aim of this paper. This paper proposes the enhancement of 3D perception by color transformation. For this, we propose a stereo matching method for obtaining a depth map and two color transformation methods such as contrast transformation and background darkening. The effectiveness of the proposed method was verified through experiments.

Multiple Orthogonal Subcarrier Modulation based High-Speed UHF RFID System for Multiple-/Dense-Interrogator Environments (다중/집중리더 환경에 적합한 다중 직교 부반송파 변조 기반 고속 UHF RFID 시스템)

  • Park, Hyung Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.67-74
    • /
    • 2016
  • This paper presents a novel multiple orthogonal subcarrier modulation based UHF band RFID communication system. In tag-to-reader communication, the demonstration system can deliver 1.6 Mbps through four subcarriers. To improve data rate while suppressing increase in circuit complexity, tag employs square-waves as the subcarriers and uses individual load modulators for each subcarrier. By using multiple orthogonal subcarrier based modulation, proposed communication system can be operated under existing UHF band RFID regulation. In reader, an OFDM demodulator is used. Since the tag backscatters the reader's CW carrier, carrier frequency offset compensation is not necessary in reader demodulator. Experimental results show that the demonstration system achieves a bit error rate of 10-5 at an Eb/N0 of 10.8 dB.

Association of self-perceived oral health and depression in the elderly: the sixth Korea national health and nutrition examination survey(the 6th KNHANES) (노인의 본인인지 구강건강상태와 우울감)

  • Cho, Han-A;Heo, Yun-Min;Kim, Hyoung-Joo;Choi, Eun sil
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.285-293
    • /
    • 2016
  • Objectives: The aim of the study was to investigate the association of self-perceived oral health and depression in the Korean elderly. Methods: The subjects were 1,329 elderly in Korea from the sixth Korea National Health and Nutrition Examination Survey (the 6th KNHANES). The dependent variable was depression that continued more than two weeks. Model I for the impacts of depression on self-reported oral health, Model II for the impacts of depression on chewing problem, Model III for the impacts of depression on speaking problem was evaluated. PASW Statistics 18.0 version was used for frequency analysis, chi-square test and logistic regression analysis. Results: Female elderly were much more prone to depression than male. Female had lower monthly compensation, less medicaid, chewing problem, speaking problem, and less education. For these reasons, they tended to have more depression than male (p<0.001). Self-perceived oral health impacts on depression included poor self-reported oral health(p<0.01), poor chewing problem(p<0.01) and poor speaking problem(p<0.05). On the other hand, male did not show a statistically significant association. Conclusions: The study showed the self-perceived oral health related quality of life had a significant influence on depression in the elderly. The continuing lifelong oral health care can prevent depression in the later life because oral health care improvement can enhance the self-perceived oral health status.