• Title/Summary/Keyword: Frequency Characteristic

Search Result 2,978, Processing Time 0.039 seconds

Free vibration analysis of clamped free circular cylindrical shells (일단고정-일단자유 원통 셸의 진동 해석)

  • 임정식
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.45-56
    • /
    • 1996
  • Frequency equation for clamped-free circular cylindrical thin shell is derived by the application of Rayleigh-Ritz method using the Sanders shell equation. The cubic frequency equation is solved for each axial and circumferential mode number. Integration of the beam characteristic funcitions was performed via Mathematica which results in more accurate integration of the beam functions that affect the accuracy of the frequency. The natural frequencies from this calculation are compared with existing results. It shows that this calculation predicts natural frequencies closer to the test results than existing results.

  • PDF

Analysis KTX wheel aged deterioration using Frequency Response Function (FRF를 이용한 KTX 차륜 경년변화 분석)

  • Yun, Cha-Jung;Lee, Sung-Uk;Jo, Kwang-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1453-1458
    • /
    • 2006
  • KTX Railway rolling stock wheel run its course to corrode, deteriorate and wear away through out the time. So it is natural that the performance and ability of wheel gets declined. The frequency characteristic analysis were accomplished to above trend and shock wave flow to wheels were examined. The result will be used to find Railway rolling stock wheel crack and maintenance method hereafter.

  • PDF

The characteristic of circuit of LC-type series and LLCC-Type parallel High frequency parallel resonant converter (LC 직렬형 및 LLCC 병렬형 고주파 공진형 컨버터의 회로 특성)

  • 차인수;박혜암
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.71-75
    • /
    • 1993
  • The Modeling analysis and design of a high frequency LC-type series and LLCC-type parallel resonant converter oprating in the continous conduction is presented. The state-plane diagram representation of the converter response gives and good insight into the converter operation. A set of characterisric frequency are plotted which design parameters can be obtained.

  • PDF

Design of Two - Dimensional IIR Digital Filters (2-차원 IIR 디지탈 필터의 설계)

  • Lee, Min-Ho;Park, Chong-Yeon
    • Journal of Industrial Technology
    • /
    • v.14
    • /
    • pp.3-17
    • /
    • 1994
  • This paper develops a design technique for approximating nonseparable frequency characteristics by sums and products of separable transfer functions. Therefore nonseparable frequency characteristics includes the four-quadrant symmetry filters. The desired filter with half plan symmetry is obtained by shifting a low pass characteristic in the frequency domain, and by combining these shifted characteristics. Also the paper develops the technique for designing recursive and nonrecursive two dimensional digital filters by the application of a complex transformation to one dimensional low pass filter.

  • PDF

Analysis of Frequency Modulation System by Analog Computer Techniques (상사형전자계산기에 의한 주파수변조계통의 해석)

  • 한만춘;변모서
    • 전기의세계
    • /
    • v.16 no.1
    • /
    • pp.14-18
    • /
    • 1967
  • To analyze th frequency modulation system the characteristic equation of the F-M system, i.e., Mathieu's equation, is derived from the equivalent circuits of direct modulation system. The analysis of F-M equation is undertaken by the Yonsei 101 Analog Computer. And the computer solution is compared with the theoretical solution. It is concluded that not only the frequency but also the amplitude of the carrier wave are changed by varying the modulation index and the system becomes unstable if the modulation index is increased near to unity.

  • PDF

A Peak Detector for Variable Frequency Three-Phase Sinusoidal Signals (가변주파수 3상 정현파 신호의 최대전압 검출기)

  • 김홍렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.210-215
    • /
    • 1999
  • The proposed detector is consists of three-phase sinusoidal signal generator and peak detector. This peak detector can detect the peak voltage value at the state of variable frequency. In experi-ment three-phase sinusoidal signals are generated from D/A converter using IBM PC and deliv-ered to the peak detector. Each signals are squared by multiplier and summed up Peak value is the square root of summed value extracted by square root circuit.

  • PDF

The Frequency Characteristics of Elastic Wave by Crack Propagation of SiC/SiC Composites

  • Kim, J.W.;Nam, K.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.110-114
    • /
    • 2012
  • We studied on the nondestructive evaluation of the elastic wave signal of SiC ceramics and SiC/SiC composite ceramics under monotonic tensile loading. The elastic wave signal of cross and unidirectional SiC/SiC composite ceramics were obtained by pencil lead method and bending test. It was applied for the time-frequency method which used by the discrete wavelet analysis algorithm. The time-frequency analysis provides time variation of each frequency component involved in a waveform, which makes it possible to evaluate the contribution of SiC fiber frequency. The results were compared with the characteristic of frequency group from SiC slurry and fiber. Based on the results, if it is possible to shift up and design as a higher frequency group, we will can make the superior material better than those of exiting SiC/SiC composites.

  • PDF

Studies on the Regulation of Calcium Activity in Myocardial Contraction (심근 수축에 있어서 Calcium작용의 조절에 관한 연구)

  • Ko, Chang-Mann;Hong, Sa-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.26 no.2
    • /
    • pp.113-120
    • /
    • 1990
  • Influences of trigger calcium on myocardial contraction from several sources were investigated on the frequency reduction-induced changes of contraction in rat left atria driven by electrical field stimulation. Rat atria elicited characteristic three phase-changes according to frequency reduction: the first rapid rise in twitch tension, the second transient fast decrease in tension and the third maintenance of twitch tension at about 200% of resting tension during high frequency. Caffeine treatment enormously suppressed the frequency reduction-induced twitch tension increase. The atrial contraction during high frequency vanished after verapamil treatment. But, during low frequency, atrial contraction revived in the presence of verapamil. Ouabain treatment and sodium depletion in superfusing solution abolished the characteristic second phase with slow frequency. These results suggest that slow calcium channel is an indispensable calcium entry route and calcium release from sarcoplasmic reticulum is an major source for trigger calcium in cardiac contraction. And sodium-calcium exchange has a modulatory roles in the regualtion of trigger calcium according to the changes of intracellular sodium concentration.

  • PDF

Calculation of the Characteristic Impedance of Transmission Lines with Periodic Structures (주기구조가 결합된 전송선로의 특성 임피던스 계산)

  • Lim, Jong-Sik;Lee, Jae-Hoon;Lee, Jun;Han, Sang-Min;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2541-2548
    • /
    • 2010
  • This paper describes the calculation for characteristic impedance of transmission line with periodic structures such as defected ground structure (DGS) and photonic bandgap (PBG). The previous method which uses the ${\lambda}$/4 transmission line model is reviewed and its disadvantage that the calculated characteristic impedance is strongly dependent on the frequency is discussed. The characteristic impedance of transmission lines with periodic structures are calculated using the ${\lambda}$/4 transmission line model and analytic method. The calculated characteristic impedance by the latter method is an almost constant value while that from the first method depends on the frequency strongly. In addition, the characteristic impedance of the transmission line with PBG is calculated and proposed, while it has been rarely studied ever. S-parameters are obtained from the measurement using the fabricated sample as well as simulation, and used for calculating the characteristic impedances and comparison. The characteristic impedances calculated from the measured S-parameters agree well with the simulated results. It is well described that the analytic method to calculate the characteristic impedance of transmission lines on uniform dielectric structures can be applied successfully to the transmission lines with periodic structures such as DGS and PBG.

Fundamental Frequency Extraction of Stay Cable based on Energy Equation (에너지방정식에 기초한 사장 케이블 기본진동수 추출)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.125-133
    • /
    • 2008
  • According to longer and longer span, dynamic instability of stay cable should be prevented. Dynamic instability occurs mainly symmetric 1st mode and antisymmetric 1st mode in stay cable. Especially symmetric 1st mode has a lot of influence on sag. Therefore fundamental frequency of stay cable is different from that of taut sting. Irvine, Triantafyllou, Ahn etc. analyzed dynamic behavior of taut cable with sag through analytical technical and their researches give important results for large bounds of Irvine parameter. But each research shows mutually different values out of characteristic (cross-over or mode-coupled) point and each solution of frequency equations of all researchers can be very difficultly found because of their very high non-linearity. Presented study focuses on fundamental frequency of stay cable. Generalized mechanical energy with symmetric 1st mode vibration shape satisfied boundary conditions is evolved by Rayleigh-Ritz method. It is possible to give linear analytic solution within characteristic point. Error by this approach shows only below 3% at characteristic point against existing researches. And taut cable don't exceed characteristic point. I.e. high accuracy, easy solving techniques, and a little bit limitations. Therefore presented study can be announced that it is good study ergonomically.