• 제목/요약/키워드: Frequency Attenuation

검색결과 746건 처리시간 0.04초

고발포 동축케이블의 전송특성 (The Properties of Transmission in the High Foamed Coaxial Cable)

  • 김성탁;박대희;김용주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.77-80
    • /
    • 1998
  • Recently, extending the local broadcasting and increasing lots of informations. The low-loss communication cable is required in proportion as frequency .The reason of transportation loss causes to using the high frequencies like hundreds of MHz or decades of GHz. For the low transportation loss. It is required the developing-technology of foaming and the high foamed insulator with the dielectric ratio of the nearest to 1. Therefor, there is the purpose of developing the insulating materials for the low dielectric ratio. Also it is important to measure the attenuation, which is one of the important parameters.sa the evaluation of transportation characteristic with frequency in the communication cable. In this paper,the result showed that the dielectric ratio(1.4) of the nearest to 1 and low attenuation with high frequency were very related to the transportation and reflection characteristics such as propagation velocity (82.27%). Delay time and voltage standing wave ratio(VSWR).

  • PDF

초음파 C-Scan을 이용한 구조용 세라믹스의 기계적 특성평가 (Evaluation of Mechanical Properties of Structural Ceramics ($Al_{2}O_{3}$) Using the High Frequency Ultrasonic C - Scan)

  • 장영권
    • 비파괴검사학회지
    • /
    • 제9권2호
    • /
    • pp.18-24
    • /
    • 1989
  • Computer-aided high frequency ultrasonic is applied to aluminum oxide(85w%, 94w%, 96w%, and 99w%) MOR(modulus of rupture) samples to evaluate mechanical properties such as density variation, pore content, elastic modulus, shear modulus, and poisson's ratio. Ultrasonic wave velocity and attenuation measurement techniques were used as an evaluator of such properties. Pulse-echo C-Scan images with different fate setting method using 50MHz center frequency 1 inch focal length transducer allows evaluation of density variation and pore content. Elastic modulus calculated with the relation of density and ultrasonic velocity. It shows good reliability as compared with resonance method. Sintered density variation of $0.025g/cm^{3}$, that is 0.6% of theoretical density in $Al_{2}O_{3}$ samples can be observed by ultrasonic velocity measurement. Attenuation measurement method qualitatively agree with 4-point fracture testing result concerning of porosity content.

  • PDF

전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성 (The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway)

  • 김재문;안승호;김양수;김철수
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

탄성 도파봉에서 고주파수 파동의 전파 특성 (Propagation Characteristics of High-frequency Waves in an Elastic Waveguide)

  • 이정구;김진오
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.816-821
    • /
    • 2010
  • The paper presents a theoretical analysis on the propagation characteristics of the high-frequency wave in an elastic waveguide whose diameter is less than or similar to the wavelength. The theoretical results were verified by comparing them with the numerical results obtained by the boundary-element method. The ratio of the waveguide diameter to the wavelength affects the number of the existing wavenumber, and thus it affects the propagation characteristics. In the media with attenuation, the trend is similar to that in the media without attenuation except the decreasing amplitude.

초음파 전달함수의 위상보정을 위한 연구 (A Study on the Phase Correction of ultratrasound transfer function)

  • 민용기;이강호;최종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.713-716
    • /
    • 1988
  • To characterize the bioloical tissues, the new methods to measure the frequency dependent attenuation are presented in this paper. In general, ultrasonic phase information was assumed by linear function of the frequency. But the minimum phase function which characterizes the frequency dispersion of tissue was derived in (2). It is very significant to measure the attenuation by using the minimum phase function to characterize the frequence dispersion of tissue. Also, we propose the phase correcting technique to take advantage of the idea that the distortion of amplitude component when the wave propagates through media.

  • PDF

SSTDR에서 시간-주파수 상관을 활용한 저압 케이블의 고장 검출 (Fault Detection of Low Voltage Cable using Time-Frequency Correlation in SSTDR)

  • 전정채;김택희;유재근
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.498-504
    • /
    • 2015
  • This paper proposed an Spread Spectrum Time Domain Reflectometry (SSTDR) using time-frequency correlation analysis in order to have more accurate fault determination and location detection than classical SSTDR despite increased signal attenuation due to the long distance to cable fault location. The proposed method was validated through comparison with classical SSTDR methods in open- and short-circuit fault detection experiments of low-voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.

폐회로 습도계를 이용한 수증기 플럭스 관측시관의 감쇠 효과에 관하여 (On the Effect of Tube Attenuation on Measuring Water Vapor Flux Using a Closed-path Hygrometer)

  • 홍진규;김준;최태진;윤진일
    • 한국농림기상학회지
    • /
    • 제2권3호
    • /
    • pp.80-86
    • /
    • 2000
  • 에디 공분산 방법은 생태계와 대기간의 질량과 에너지 교환을 측정하는데 널리 사용되고 있다. 이 방법은 다른 미기상학적 방법과는 달리 많은 가정을 필요로 하지 않는 직접 측정으로서, 스칼라의 농도 변화를 측정하기 위해 고속 반응의 개회로 또는 폐회로 기기를 필요로 한다. 후자를 사용할 경우, 흡입된 공기가 관을 통과하면서 스칼라의 농도 변동의 감쇠가 일어난다. 이러한 관 감쇠 효과는 측정하고자 하는 난류 플럭스를 과소 평가하게 한다. 난류 흐름의 감쇠 효과를 정량화하기 위해서 개회로 기기와 폐회로 기기로 측정된 수증기 농도를 각각 분석하였다. 통계적 분석에 의하면, 폐회로 기기에서 얻어진 스펙트럼이 0.5 Hz 이상의 영역에서 개회로 기기에서 얻어진 스펙트럼과 서로 다름을 보였다. 낮에는 관 감쇠에 의한 수증기 플럭스의 손실이 5% 이내였으나, 밤에는 풍속이 작고, 난류의 강도가 약하여 플럭스 손실이 상대적으로 크게 나타났다. 이론적으로 계산된 플럭스 손실은 관측 결과와 고주파수 영역에서 약간의 차이를 보였는데, 이것은 수증기가 관의 벽과 상호 작용하면서 플럭스 측정에 영향을 주었기 때문인 것으로 추정된다. 결론적으로, 개회로나 폐회로기기 모두 5% 오차 내에서 수증기 플럭스 관측에 사용할 수 있다. 그러나 대기가 안정할 때는 플럭스 산출시 고주파수에서의 영향을 신중히 고려해 주어야 한다.

  • PDF

광대역 관측소 하부 암석의 고주파수 탄성파 속도 및 감쇠상수에 대한 연구 (High frequency P velocity and attenuation coefficient of the rocks under the broad-band seismic station)

  • 이덕기;오석훈;윤용훈;양준모
    • 지구물리
    • /
    • 제5권3호
    • /
    • pp.165-174
    • /
    • 2002
  • 기상청 광대역 관측소 6개소에 대한 표층 암석의 탄성파 전달속도 및 감쇠상수를 도출하기 위하여, 실험실에서 고주파 탄성파를 암석시료에 통과시켜 도달시간 및 파형을 분석하였다. 측정되어진 암석시료의 속도는 3.2 km/s에서 5.6 km/s의 범위를 가지며 이는 암석종류, 광물입자, 배열상태, 그리고 풍화의 정도에 따라서 달라진다고 추정된다. 감쇠상수는 0.06에서 4.3 db/kHz-m의 범위를 보이며 대체로 암석시료 속도와 감쇠상수는 반비례하는 경향이 있다. 각 관측소 지진파의 평균도달시간이상과 실험실에서 측정한 탄성파 속도를 비교하여 본 결과, 비례하는 경향을 보임을 알 수 있었다.

  • PDF

대칭적인 감쇠 특성을 갖는 대역 통과 여파기 (A New Band-Pass Filter with Symmetrical Attenuation Characteristics)

  • 배주석;임종식;김귀수;안달
    • 한국전자파학회논문지
    • /
    • 제19권8호
    • /
    • pp.884-890
    • /
    • 2008
  • 본 논문에서는 어드미턴스 인버터로 구성된 대역 통과 여파기의 주파수 응답 특성을 고찰하고, 그 결과 통과 대역을 중심으로 하여 상 하측 주파수 저지 대역의 신호 감쇠 특성이 비대칭임을 확인한다. 인버터로 구성된 대역 통과 여파기의 비대칭적인 감쇠 특성을 개선하기 위해 변형된 회로의 구조와 설계식을 제안한다. 제안된 회로 구조와 설계식을 이용하여 대역 통과 여파기를 설계하고, 설계된 여파기의 특성을 시뮬레이션 및 실험을 통하여 비대칭적인 감쇠 특성이 최적화 설계 기법이나 반복 설계 및 실험 과정 없이 보정됨을 확인한다.

유도초음파의 감쇠계수에 대한 실험적 고찰 (Experimental Investigation for the Attenuation Coefficient of Ultrasonic Guided Wave)

  • 이동진;조윤호;이준현;신동철
    • 비파괴검사학회지
    • /
    • 제29권5호
    • /
    • pp.458-465
    • /
    • 2009
  • 일반적인 산업현장에서 내부결함 평가를 위해 사용되어온 유도초음파기법은 비결함 지역에서는 에너지 감쇠를 고려하지 않고 적용되어 왔다. 결함 지역에서의 신호는 산란과 반사에 의해서 분명한 감쇠가 발생하지만 비결함 지역에서도 작은 감쇠가 발생한다. 또한 분산선도에서 판파(Lamb wave)는 각 두께, 주파수에 의해 분산성이 달라지기에 각 모드에 적합한 감쇠계수를 찾는 것은 중요하다. 이를 위해 접촉식 PZT(piezoelectric)센서를 이용한 pitch-catch 방식으로 거리에 따른 각 모드의 감쇠계수를 구하였다. 본 연구에서는 흔히 쓰이는 알루미늄과 구리판으로, 두께 차이, 모드 차이, 재질 차이에 의한 실험적인 감쇠율을 구하는데 중점을 두었다. 그 결과 각 변수에 따라 감쇠계수는 달라지며, 정량화가 필요하다는 것을 확인하였다.