• Title/Summary/Keyword: Frequency Attenuation

Search Result 745, Processing Time 0.038 seconds

Silencer structure for exhaust noise attenuation performance in the high frequency range (500 Hz 이상 고주파수 영역에서 배기소음 저감을 위한 소음기 구조)

  • KIM, Sang-Am
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.3
    • /
    • pp.255-261
    • /
    • 2018
  • High power trends in the diesel engines due to engine downsizing do not provide noise attenuation that can be satisfied with the performance of the existing silencer on account of high frequency increases in the exhaust noise. This study improves the attenuation performance of the exhaust silencer of the diesel engine and suggests silencer structure that performs best attenuation performance, especially at the high frequency range in the exhaust noise. It proposes dual silencer structure with an average attenuation performance of 6.4 dB and a maximum of 10.7 dB in the high frequency range (over 500 Hz), and analyzes its characteristics compared with the existing silencer. The performance analysis is performed according to 'Measurements on silencers in situation-ISO 11820:1996 Acoustics' and describes the results of comparative analysis with the existing silencer.

Seismic attenuation from VSP data in methane hydrate-bearing sediments (메탄 하이드레이트 부존 퇴적층으로부터 획득한 수직탄성파 (VSP) 자료에서의 탄성파 진폭 감쇠)

  • Matsushima, Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • Recent seismic surveys have shown that the presence of methane hydrate (MH) in sediments has significant influence on seismic attenuation. I have used vertical seismic profile (VSP) data from a Nankai Trough exploratory well, offshore Tokai in central Japan, to estimate compressional attenuation in MH-bearing sediments at seismic frequencies of 30-110 Hz. The use of two different measurement methods (spectral ratio and centroid frequency shift methods) provides an opportunity to validate the attenuation measurements. The sensitivity of attenuation analyses to different depth intervals, borehole irregularities, and different frequency ranges was also examined to validate the stability of attenuation estimation. I found no significant compressional attenuation in MH-bearing sediments at seismic frequencies. Macroscopically, the peaks of highest attenuation in the seismic frequency range correspond to low-saturation gas zones. In contrast, high compressional attenuation zones in the sonic frequency range (10-20 kHz) are associated with the presence of methane hydrates at the same well locations. Thus, this study demonstrated the frequency-dependence of attenuation in MH-bearing sediments; MH-bearing sediments cause attenuation in the sonic frequency range rather than the seismic frequency range As a possible reason why seismic frequencies in the 30-110 Hz range were not affected in MH-bearing sediments, I point out the effect of thin layering of MH-bearing zones.

Improved Attenuation Estimation of Ultrasonic Signals Using Frequency Compounding Method

  • Kim, Hyungsuk;Shim, Jaeyoon;Heo, Seo Weon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.430-437
    • /
    • 2018
  • Ultrasonic attenuation is an important parameter in Quantitative Ultrasound and many algorithms have been proposed to improve estimation accuracy and repeatability for multiple independent estimates. In this work, we propose an improved algorithm for estimating ultrasonic attenuation utilizing the optimal frequency compounding technique based on stochastic noise model. We formulate mathematical compounding equations in the AWGN channel model and solve optimization problems to maximize the signal-to-noise ratio for multiple frequency components. Individual estimates are calculated by the reference phantom method which provides very stable results in uniformly attenuating regions. We also propose the guideline to select frequency ranges of reflected RF signals. Simulation results using numerical phantoms show that the proposed optimal frequency compounding method provides improved accuracy while minimizing estimation bias. The estimation variance is reduced by only 16% for the un-compounding case, whereas it is reduced by 68% for the uniformly compounding case. The frequency range corresponding to the half-power for reflected signals also provides robust and efficient estimation performance.

Measurement Ultrasound Attenuation by Using Phase Spectral Difference Method (위상 스펙트럴 차분법에 의한 초음파 감쇠 계수의 측정)

  • Min, Yong-Ki;Choi, Jong-Ho;Lee, Kang-Ho;Choi, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1243-1246
    • /
    • 1987
  • To characterize the biological tissues, the new methods to measure the frequency dependent attenuation are presented in this paper. In general, ultrasonic phase information was assumed by linear function of the frequency. But, the minimum phase function which characterizes the frequency dispersion of tissue was derived in [l]. It is very significant to measure the attenuation by using the minimum phase function to characterize the frequency dispersion of tissue. Therefore, a more efficient method measuring the frequency dependent attenuation are proposed by using the estimated sound velocity and polarity of reflected signal. To verify the algorithms, pulse reflection experiments are performed.

  • PDF

A Study on Temperature Features of Broadband Ultrasonic Attenuation (초음파 광역 감쇠의 온도 특성에 관한 연구)

  • 신정식;안중환;한승무;김형준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.245-248
    • /
    • 1997
  • The distilled water is used for the ultrasonic wave propagating material in the measurements of broadband ultrasonic attenuation (BUA) that is applied in industrial and medical applications, The acoustic impedance of water is significantly changed with its temperature. Therefore, the quantitative evaluation of BUA with temperature and the ultrasonic wave propagating distance is highly needed. In this study, we evaluated the variation of attenuation with change in temperature. To measure the variation of BUA in the low frequency region at the temperatures, 27$^{\circ}C$, 29$^{\circ}C$, and 31$^{\circ}C$, we tested the Plyethylene, Teflon, MC-Nylon, Urethane specimens and analyzed the center frequency, frequency bandwidth, spectral peak amplitude. The results showed that BUA value appeared to be lower with increasing temperature. This may be due to the fact that the frequency feature of ultrasonic wave is affected by not only the specific gravity, acoustic impedence, but material crystalline, porosity, the distance of ultrasonic wave propagation in water.

  • PDF

Estimation of Ultrasound Attenuation Coefficients with Nonlinear Frequency Dependency for Human Liver (인체간 조직의 비선형 초음파 감쇄상수 추정)

  • Lee, No-Sung;Woo, Kwang-Bang;Yu, Hyung-Shik
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.121-130
    • /
    • 1990
  • In this study, the coefficients of ultrasound attenuation for human liver were determined in 6 normal humans and in 38 patients with diffuse liver disease. The coefficients with linear frequency dependency as well as nonlinear frequency dependency were evaluated. Gaussian pulse propagating in a lossy medium suffers downshifting of a center frequency and decreasing in the bandwidth. Such changes in frequency domain spectrum were quantified in terms of changes in the attenuation coefficients with nonlinear dependency, which in turn improve clinical Implications of the coefficients. Statistical analysis shows that the attenuation coefficients evaluated with nonlinear dependency reflect an improved accuracy for the diffuse liver disease than those with linear dependency. The discriminant analysis also indicate the improved classification with nonlinear dependency(75%) than with linear dependency(61%).

  • PDF

Design of Multilayer Ceramic Chip Band pas Filter with an attenuation pole (감쇠극을 갖는 적층형 세라믹 칩 필터의 설계)

  • 강종윤;심성훈;최지원;박용욱;윤석진;김현재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.123-126
    • /
    • 2002
  • A proposed multi-layer ceramic (MLC) chip type band-pass filter (BPF) is presented. The MLC chip BPF has the benefits of low cost and small size. The BPF consists of coulped stripline resonators and coupling capacitors. The BPF is designed to have an attenuation pole at below the passband for a receiver band of IMT-2000 handset. The computer-aided design technology is applied for analysis of the BPF frequency characteristics. The passband and attenuation pole depend the coupling between resonators and coupling capacitance. The frequency characterics of the passband and attenuation pole are analysed with the variance of the coupling between resonators and coupling capacitance. An equivalent circuit and structure of MLC chip BPF are proposed. The frequency characteristics of the BPF is well acceptable for IMT-2000 application.

  • PDF

Design of Multilayer Ceramic Chip Band Pass Filter with an Attenuation Pole (감쇠극을 갖는 적층형 세라믹 칩 필터의 설계)

  • 강종윤;심성훈;최지원;박용욱;이동윤;윤석진;김현재
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.8
    • /
    • pp.740-743
    • /
    • 2003
  • A multi-layer ceramic (MLC) chip type band-pass filter (BPF) is presented. The MLC chip BPF has the benefits of low cost and small size. The BPF consists of coulped stripline resonators and coupling capacitors. The BPF is designed to have an attenuation pole at below the passband for a receiver band of IMT-2000 handset. The computer-aided design technology is applied for analysis of the BPF frequency characteristics. The passband and attenuation pole depend on the coupling between resonators and coupling capacitance. The frequency characterics of the passband and attenuation pole are analyzed with the variation of the coupling between resonators and coupling capacitance. An equivanlent circuit and structure of MLC chip BPF are proposed. The frequency characteristics of the BPF is well acceptable for IMT-2000 application.

A Study on Sound Attenuation by Structure Improvement of Silencer for Exhaust Fan (배기소음기의 구조개선에 의한 소음감쇠 효과에 관한 연구)

  • 윤세철;이해경
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.2
    • /
    • pp.32-38
    • /
    • 1995
  • The silencers are used to attenuate noise generated by the exhaust fan for industrial processes. The types of silencers applied in this study are absorptive duct silencer, expansion chamber, absorptive chamber and resonator. This study was carried out to verify the attenuation by the various silencers and elements. As a result, the difference of attenuation between the calculation and the measurement was about 1-7㏈. The attenuation by absorptive duct silencer and absorptive chamber was negligible at frequencies below 250Hz. The expansion chamber should be used for low frequency applications where the absorptive duct silencer was Ineffective. The attenuation by resonator may be realised when the ratio of frequency to resonant frequency approaches 1.

  • PDF

Comparison of The Attenuation Measurement Methods for Electromagnetic Partial Discharge Signal in 25.8 kV Gas Insulated Switchgear (25.8 kV GIS에서 전자기파 부분방전신호 감쇠특성 측정방법 비교)

  • Goo, Sun-Geun;Han, Ki-Sun;Kwak, Joo-Sik;Joo, Hyung-Jun;Jeong, Moon-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1281-1287
    • /
    • 2015
  • We report the characteristics and differences of two types of attenuation measurement methods for electromagnetic partial discharge signal in GIS. The pulse method is to measure the attenuated waveforms in time domain and coverts them into frequency domain to get the attenuation spectra of given GIS section. This method simulates the real partial discharge signal. The frequency swept continuous wave method can obtain attenuation spectra directly so that it gives attenuation with low noise floor and simplicity. We show that both methods are effective and exchangeable because the attenuation results measured by two methods have similar trends