배기소음기의 구조개선에 의한 소음감쇠 효과에 관한 연구
A Study on Sound Attenuation by Structure Improvement of Silencer for Exhaust Fan
초록
The silencers are used to attenuate noise generated by the exhaust fan for industrial processes. The types of silencers applied in this study are absorptive duct silencer, expansion chamber, absorptive chamber and resonator. This study was carried out to verify the attenuation by the various silencers and elements. As a result, the difference of attenuation between the calculation and the measurement was about 1-7㏈. The attenuation by absorptive duct silencer and absorptive chamber was negligible at frequencies below 250Hz. The expansion chamber should be used for low frequency applications where the absorptive duct silencer was Ineffective. The attenuation by resonator may be realised when the ratio of frequency to resonant frequency approaches 1.
키워드