• Title/Summary/Keyword: Framed structures

Search Result 262, Processing Time 0.02 seconds

Constitutive models of concrete structures subjected to seismic shear

  • Laskar, Arghadeep;Lu, Liang;Qin, Feng;Mo, Y.L.;Hsu, Thomas T.C.;Lu, Xilin;Fan, Feng
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.627-645
    • /
    • 2014
  • Using OpenSees as a framework, constitutive models of reinforced, prestressed and prestressed steel fiber concrete found by the panel tests have been implemented into a finite element program called Simulation of Concrete Structures (SCS) to predict the seismic behavior of shear-critical reinforced and prestressed concrete structures. The developed finite element program was validated by tests on prestressed steel fiber concrete beams under monotonic loading, post tensioned precast concrete column under reversed cyclic loading, framed shear walls under reversed cyclic loading or shaking table excitations, and a seven-story wall building under shake table excitations. The comparison of analytical results with test outcomes indicates good agreement.

SSI effects on the redistribution of seismic forces in one-storey R/C buildings

  • Askouni, Paraskevi K.;Karabalis, Dimitris L.
    • Earthquakes and Structures
    • /
    • v.20 no.3
    • /
    • pp.261-278
    • /
    • 2021
  • In the current work, a series of seismic analyses of one-storey asymmetrical reinforced concrete (R/C) framed buildings is accomplished while the effect of soil deformability on the structural response is investigated. A comparison is performed between the simplified elastic behavior of R/C elements according to the structural regulations' instructions to the possible non-linear behavior of R/C elements under actual circumstances. The target of the time history analyses is the elucidation of the Soil-Structure Interaction (SSI) effect in the seismic behavior of common R/C structures by examining the possible elastic or elastoplastic behavior of R/C sections because of the redistribution of the internal forces by employing a realistic damage index. The conclusions acquired from the presented elastic and elastoplastic analyses supply practical guidelines towards the safer design of structures.

Vibration Measurements of the Foot-Bridges Using Mobile-Phone (휴대용 계측기를 이용한 보도교 진동계측분석)

  • Do, Ki-Young;Yoon, Sung-Won;Kim, Do-Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2014
  • The design of foot-bridge is often influenced by natural frequency. Consequently, vibration frequency becomes important. The empirical expressions used to quantify this parameter at the design phase have not been developed enough to give guideline to Korean foot-bridge. This paper is concerned with the vertical natural frequency of steel foot-bridges. It describes the vibration measurement methods employed for testing structures and presents reliable methods of assessing natural frequency from jumping vibration tests. Data from measurements on 16 structures in Seoul are given. Regression formulas of natural frequency for steel-framed foot-bridges are suggested. Finally, obtained formula are compared with empirical expressions of Seoul City's guideline.

Inelastic Behavior of Steel Frames with Buckling Restrained Braced (비좌굴가새가 설치된 골조의 비탄성거동)

  • Kim Jin-Koo;Park Jun-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.97-104
    • /
    • 2005
  • The seismic behavior of framed structure with Chevron-type bucking restrained braces were investigated and their behavior factors were evaluated following the procedure proposed in ATC-19 & ATC-34. Two types of structures, building frame systems and dual systems, with 4, 8, 12, and 16 stories were designed per the IBC 2000, the AISC LRFD and the AISC/SEAOC Recommended Provisions for BRBF. Nonlinear static pushover analyses were carried out to observe the plastic hinge formation and to identify the loads and the displacements at the yield and the ultimate states. Time history analyses were also carried out to compute the permanent displacement md the dissipated hysteretic energy. According to the analysis results, the response modification factors of model structures fumed out to be larger than what is proposed in the provision in low story structures, and a little smaller in medium-story structures. The dual systems, even though designed with smaller seismic load, showed superior static and dynamic performances.

  • PDF

Simplified Collapse Analysis of Ship Transverse Structures (선체 횡구조물의 단순화된 최종 강도 해석)

  • P.D.C.,Yang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.4
    • /
    • pp.57-66
    • /
    • 1989
  • In this paper, a theory for the static analysis of large plastic deformations of 3-dimensional frames, aiming at application to the collapse analysis of ship structures, is presented. In the frame analysis formulation, effects of shear deformations are included. A plastic hinge is inserted into the field of a beam end, and post. failure deformation of the plastic hinge is characterized by finite rotations and extensions. In order to model deep web frames of ship's structures into a framed structures, collapse of thin-walled plate girders is investigated. The proposed analysis method is applied to several ship structural models in the references.

  • PDF

Dwelling Quality Evaluation of Rural Houses Constructed with Industrialized Wall Structures (공업화 구조 농촌주택의 거주성 평가)

  • 최윤정;윤정숙
    • Journal of the Korean housing association
    • /
    • v.13 no.5
    • /
    • pp.9-20
    • /
    • 2002
  • The purpose of this study are to evaluate the dwelling quality of rural houses constructed with industrialized wall structures(ALC; Autoclaved Light weight Concrete, SRC; Steel Fiber Reinforced Concrete, ST'L; Steel Framed Insulating Panel), and to establish a method of dwelling quality evaluation. The questionnaire survey by mail was done, for investigating the residents' responses to indoor environment, durability, and economic aspect. The respondents are 118 residents living in rural houses constructed with industrialized wall structures. Physical elements of indoor environment(temperature, humidity, air quality, and noise level) were measured in three sample houses, which were selected considering of architectural characteristics. The findings are as follows; 1) As a result of questionnaire survey, residents' responses to dwelling quality are generally positive. 2) As a result of measurement, indoor environments of sample houses are in relatively comfortable condition. 3) As a summary of research, ALC and ST'L are evaluated as recommendable structures for a rural house.

Characteristics of Sound Reduction Index through Small Sized Lightweight Panel (소형 경량판넬을 이용한 차음성능 영향요인별 음향감쇠계수 분석)

  • Yang, Hong-Seok;Kim, Myung-Jun;Jeong, Gab-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.138-147
    • /
    • 2007
  • Recently, framed structure is increasingly being used as apartment structure due to the advantages during remodeling. Therefore, the use of lightweight panel as separating wall is increasing. To construct lightweight panel structures with sound insulation performance appropriate to the conditions of each field, measurement of sound reduction index(SRI) through panel structures should be performed. In this study, measurement of SRI through 46 kinds of panel structures was performed in the condition of various factors such as surface density, air space and absorber. The result showed that SRI of panel structures was generally higher by increasing of surface density. In the case of double panel with no absorber, SRI at below critical frequency was gradually increased according to rise of air space. Double panel with absorber make remarkable improvement in SRI at low frequency, but there is a little difference compared with SRI of double panel with no absorber over critical frequency.

  • PDF

Rate-sensitive analysis of framed structures part II: implementation and application to steel and R/C frames

  • Fang, Q.;Izzuddin, B.A.
    • Structural Engineering and Mechanics
    • /
    • v.5 no.3
    • /
    • pp.239-256
    • /
    • 1997
  • The companion paper presents a new three-parameter model for the uniaxial rate-sensitive material response, which is based on a bilinear static stress-strain relationship with kinematic strain-hardening. This paper extends the proposed model to trilinear static stress-strain relationships for steel and concrete, and discusses the implementation of the new models within an incremental-iterative solution procedure. For steel, the three-parameter rate-function is employed with a trilinear static stress-strain relationship, which allows the utilisation of different levels of rate-sensitivity for the plastic plateau and strain-hardening ranges. For concrete, on the other hand, two trilinear stress-strain relationships are used for tension and compression, where rate-sensitivity is accounted for in the strain-softening range. Both models have been implemented within the nonlinear analysis program ADAPTIC, which is used herein to provide verification for the models, and to demonstrate their applicability to the rate-sensitive analysis of steel and reinforced concrete structures.

Effective number of mega-bracing, in order to minimize shear lag

  • Zahiri-Hashemi, Rouzbeh;Kheyroddin, Ali;Farhadi, Basir
    • Structural Engineering and Mechanics
    • /
    • v.48 no.2
    • /
    • pp.173-193
    • /
    • 2013
  • In this paper, influence of geometric configurations of multi-story bracing on shear lag behaviour of braced tube structures is investigated. The shear lag of 24-, 36- and 72-story braced tube structures are assessed considering all possible configurations of overall X and Chevron bracing types. Based on the analytical results, empirical equations, useful for the preliminary design phase, are proposed to provide the optimum number of stories that braced, in order to exert minimum shear lag on structures. Studying the interaction behaviour of a tube and different bracing types along with paying attention to the shear lag behaviour, a better explanation about the reasons behind the efficiency of a specific bracing module in decreasing the shear lag is developed. The analytical results show that there are distinct differences between the anatomy of braced tube structures with X and Chevron bracing regarding the shear lag behaviour.

A Theoretical Investigation on Shakedown Analysis of Framed Structures (강뼈대 구조물의 소성안정 해석에 관한 이론적 연구)

  • Lee, Jong-Seok
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.71-77
    • /
    • 1988
  • For the collapse of structures due to the variable repeated load, two types of collapse mechanisms, i.e., incremental collapse and alternating plasticity, exist. Under the similar variable repeated loading conditions there exists shakedown state in the structures. In shakedown state, the number of plastic hinges are not increased and all further loading will be resulted in the elastic moment changes. Namely, under the shakedown state, structures do not collapse. In this investigation, shakedown analysis are performed by composing new computer programs. Basic theories employed to compose the programs are as follows. 1. Newton-Raphson methods are added to the existing matrix method for the plastic analysis. 2. An effort to construct the stiffness of axial and bending springs attached at both ends of the member has been made. By using the programs developed, it is possible to anticipate the collapse mechanisms (Incremental collapse, alternating plasticity). Lastly for the verification of performance of the program, demonstration examples have been solved and the results are compared with other sources.

  • PDF