• 제목/요약/키워드: Fraction of nonconforming

검색결과 24건 처리시간 0.017초

Minimization of Inspection Cost in an Inspection System Considering the Effect of Lot Formation on AOQ

  • Yang, Moon-Hee
    • Management Science and Financial Engineering
    • /
    • 제16권1호
    • /
    • pp.119-135
    • /
    • 2010
  • In this paper, we readdress the optimization problem for minimizing the inspection cost in a back-light unit inspection system, which forms a network including a K-stage inspection system, a source inspection shop, and a re-inspection shop. In order to formulate our objective function when the system is in a steady state, assuming that the number of nonconforming items in a lot follows a binomial distribution when a lot is formed for inspection, we make a steady-state network flow analysis between shops, and derive the steady-state amount of flows between nodes and the steady-state fraction defectives by solving a nonlinear balance equation. Finally we provide some fundamental properties and an enumeration method for determining an optimal value of K which minimizes our objective function. In addition, we compare our results numerically with previous ones.

미세공정변동에서 관리도의 경제적 설계를 위한 조사연구 (A Survey on The Economic Design of Control Chart in Small Process Variation)

  • 김종걸;엄상준;김형만
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 춘계학술대회
    • /
    • pp.533-546
    • /
    • 2013
  • 이 논문은 미세공정변동에서 극소불량을 감지하는 관리도의 경제적 설계를 개발하기 위한 조사연구이다. 일반적인 관리도의 설계는 통계적 설계와 경제적 설계로 구분할 수 있다. 공정의 변동 원인에 따라 샘플의 간격(h), 샘플의 크기(n), 관리한계선(k) 등의 설계 모수를 최적접근방법으로 결정을 하는 경제적 설계의 모델을 조사하였다. 관리도의 경제적 설계는 공정의 관리이상상태를 효율적으로 감지하여 관리상태로 정상화 시키는 것에 대한 공정의 개선비용과 기대품질비용을 절약 할 수 있는 최적설계 방안이다. 그리고 Shewhart 관리도의 X-bar 통계량으로 극소불량을 검출 하는것에 한계가 있기 때문에 Zp 통계량과 분포를 설계하여 극소불량을 빠르게 감지할 수 있는 Zp 관리도의 설계를 적용하고, 미세공정변동을 정확하게 감지할 수 있는 CUSUM 관리도를 동시에 적용하였다. 따라서, 미세공정변동과 극소불량을 동시에 관리 할 수 있는 Zp-CUSUM 관리도의 통계적 설계 구조를 체계화 하였으며, 기존의 경제적 설계의 모델을 비교 분석하여 새로운 경제적 설계에 대한 모델을 제안하고자 한다.

  • PDF

Exponentially Weighted Moving Average Chart for High-Yield Processes

  • Kotani, Takayuki;Kusukawa, Etsuko;Ohta, Hiroshi
    • Industrial Engineering and Management Systems
    • /
    • 제4권1호
    • /
    • pp.75-81
    • /
    • 2005
  • Borror et al. discussed the EWMA(Exponentially Weighted Moving Average) chart to monitor the count of defects which follows the Poisson distribution, referred to the $EWMA_c$ chart, as an alternative Shewhart c chart. In the $EWMA_c$ chart, the Markov chain approach is used to calculate the ARL (Average Run Length). On the other hand, in order to monitor the process fraction defectives P in high-yield processes, Xie et al. presented the CCC(Cumulative Count of Conforming)-r chart of which quality characteristic is the cumulative count of conforming item inspected until observing $r({\geq}2)$ nonconforming items. Furthermore, Ohta and Kusukawa presented the $CS(Confirmation Sample)_{CCC-r}$ chart as an alternative of the CCC-r chart. As a more superior chart in high-yield processes, in this paper we present an $EWMA_{CCC-r}$ chart to detect more sensitively small or moderate shifts in P than the $CS_{CCC-r}$ chart. The proposed $EWMA_{CCC-r}$ chart can be constructed by applying the designing method of the $EWMA_C$ chart to the CCC-r chart. ANOS(Average Number of Observations to Signal) of the proposed chart is compared with that of the $CS_{CCC-r}$ chart through computer simulation. It is demonstrated from numerical examples that the performance of proposed chart is more superior to the $CS_{CCC-r}$ chart.

붓스트랩에 기초하여 조정한 관리한계를 사용하는 CCC-r 관리도의 성능 (Performance of CCC-r charts with bootstrap adjusted control limits)

  • 김민지;이재헌
    • 응용통계연구
    • /
    • 제33권4호
    • /
    • pp.451-466
    • /
    • 2020
  • CCC-r 관리도는 불량률이 매우 낮은 고품질 공정을 관리하는 데 효율적이라고 알려져 있다. 대부분의 공정에서 공정 모수의 값은 알려져 있지 않기 때문에 제1국면에서 이를 추정해야 하는데, 표본의 크기가 충분히 크지 않은 경우 추정 오차가 발생하여 원하는 관리상태에서의 성능을 만족하지 못하는 경우가 발생한다. 뿐만 아니라 제1국면에서 추출하는 표본에 따른 산포로 인하여 관리상태일 때의 성능의 산포 또한 커지게 된다. 이러한 문제를 해결하기 위해 이 논문에서는 관리상태일 때 신호까지의 평균관측개수가 사전에 정한 확률로 목표하는 값보다 큰 값을 갖도록, 붓스트랩 알고리즘을 사용하여 CCC-r 관리도의 관리한계를 조정하는 절차를 제안하였다. 이때 고품질 공정에 적용하기 위하여 최대우도추정량 대신 베이즈추정량을 사용하여 불량률을 추정하였다. 다양한 상황에 대해 모의실험을 수행한 결과, 제안된 절차는 CCC-r 관리도의 관리상태 성능을 크게 향상시킴을 알 수 있었다.