• 제목/요약/키워드: Fraction of building volume

검색결과 48건 처리시간 0.026초

Point load actuation on plate structures based on triangular piezoelectric patches

  • Tondreau, Gilles;Raman, Sudharsana Raamanujan;Deraemaeker, Arnaud
    • Smart Structures and Systems
    • /
    • 제13권4호
    • /
    • pp.547-565
    • /
    • 2014
  • This paper investigates the design of a perfect point load actuator based on flat triangular piezoelectric patches. Applying a difference of electric potential between the electrodes of a triangular patch leads to point loads at the tips and distributed moments along the edges of the electrodes. The previously derived analytical expressions of these forces show that they depend on two factors: the width over height (b/l) ratio of the triangle, and the ratio of the in-plane piezoelectric properties ($e_{31}/e_{32}$) of the active layer of the piezoelectric patch. In this paper, it is shown that by a proper choice of b/l and of the piezoelectric properties, the moments can be cancelled, so that if one side of the triangle is clamped, a perfect point load actuation can be achieved. This requires $e_{31}/e_{32}$ to be negative, which imposes the use of interdigitated electrodes instead of continuous ones. The design of two transducers with interdigitated electrodes for perfect point load actuation on a clamped plate is verified with finite element calculations. The first design is based on a full piezoelectric ceramic patch and shows superior actuation performance than the second design based on a piezocomposite patch with a volume fraction of fibres of 86%. The results show that both designs lead to perfect point load actuation while the use of an isotropic PZT patch with continuous electrodes gives significantly different results.

비정질 붕소강 섬유를 혼입한 콘크리트의 역학적 성능 및 중성자 차폐성능 평가 (Mechanical Properties and Neutron Shielding Performance of Concrete with Amorphous Boron Steel Fiber)

  • 이준철;김화중
    • 한국건축시공학회지
    • /
    • 제17권1호
    • /
    • pp.9-14
    • /
    • 2017
  • 본 연구에서 비정질 붕소강 섬유를 혼입한 콘크리트의 역학적 성능 및 중성자 차폐성능을 평가하였다. 비정질 붕소강 섬유를 콘크리트 체적 대비 0.25%에서 1.0%까지 혼입하여 굳지 않은 콘크리트의 공기량과 슬럼프값, 경화된 콘크리트의 압축강도, 휨강도, 휨인성 및 중성자 차폐성능을 평가하였다. 실험결과, 비정질 붕소강 섬유의 혼입량이 증가할수록 콘크리트의 휨인성 및 중성자 차폐성능이 향상되는 것으로 나타났다. 이를 통해 비정질 붕소강 섬유의 혼입이 중성자 차폐성능 뿐만 아니라 역학적 성능을 효과적으로 개선시켜 줄 것이라고 기대된다.

Dynamic characterization of a CNT reinforced hybrid uniform and non-uniform composite plates

  • Lakshmipathi, Jakkamputi;Vasudevan, Rajamohan
    • Steel and Composite Structures
    • /
    • 제30권1호
    • /
    • pp.31-46
    • /
    • 2019
  • In the present study, the various dynamic properties of MWCNT embedded fiber reinforced polymer uniform and tapered composite (MWCNT-FRP) plates are investigated. Various configurations of a tapered composite plate with ply-drop off and uniform composite plate have been considered for the development of the finite element formulation and experimental investigations. First order shear deformation theory (FSDT) has been used to derive the kinetic and potential energy equations of the hybrid composite plates by including the effect of rotary inertia, shear deformation and non-uniformity in thickness of the plate. The governing equations of motion of FRP composite plates without and with MWCNT reinforcement are derived by considering a nine- node rectangular element with five degrees of freedom (DOF) at each node. The effectiveness of the developed finite element formulation has been demonstrated by comparing the natural frequencies and damping ratio of FRP composite plates without and with MWCNT reinforcement obtained experimentally. Various parametric studies are also performed to study the effect of CNT volume fraction and CNT aspect ratio of the composite plate on the natural frequencies of different configurations of CNT reinforced hybrid composite plates. Further the forced vibration analysis is performed to compare the dynamic response of the various configurations of MWCNT-GFRP composite plate with GFRP composite plate under harmonic excitations. It was observed that the fundamental natural frequency and damping ratio of the GFRP composite plate increase approximately 8% and 37% respectively with 0.5wt% reinforcement of MWCNT under CFCF boundary condition. The natural frequencies of MWCNT-GFRP hybrid composite plates tend to decrease with the increase of MWCNT volume fraction beyond 2% due to agglomeration of CNT's. It is also observed that the aspect ratio of the CNT has negligible effect on the improvement of dynamics properties due to randomly orientation of CNT's.

혼합모래를 사용한 시멘트 모르터의 특성에 관한 연구 (A Study on the Properties of Cement Mortar Using Blended Sand)

  • 박용규;김민호;윤기원;류현기;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.65-68
    • /
    • 2005
  • This paper investigated the engineering properties of cement mortar mixed with more than 2 kinds of sand. For fresh mortar properties, unit volume weight is constant regardless of mixing content and type of sand. An increase in contents of river and crushed sand resulted in an increase in flow, whereas an increase in recycled sand contents reduced flow. Gap between maximum flow in N3C0R0 and minimum flow in N0C0R3 exhibited about $12\%$. Compressive strength at 28 days ranged from 32 to 36 MPa in order for crushed sand, river sand and recycled sand. Mortar with mixed sand along with river sand and crushed sand showed compressive strength comparable to crushed sand. An increase of fraction of recycled sand in mixed sand resulted in a decrease in compressive strength. For drying shrinkage, N0C0R3 had the largest drying shrinkage among various mixture type. The combination of large contents of recycled sand and small contents of river and crushed sand had a large amount of drying shrinkage.

  • PDF

안전성 향상을 위한 도로터널 등급에 관한 연구 (A Study of Classification of Road Tunnel for Fire Safety)

  • 유지오;이동호;신현준
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.112-119
    • /
    • 2005
  • In road tunnel, in order to prevents an accident and minimize the damage of an accident in the case of fire, safety facilities and equipments are integral parts. The type and amount of safety facilities are based on tunnel type and length, traffic flow rate, etc. Therefore many countries use a tunnel classification system that categories tunnel into groups, and specifies the necessary emergency equipment for each group. In this study, for the purpose of classifying tunnel based on tunnel ist investigated the domestic and foreign standards and regulations for safety of road tunnel. As a results, we suggest the method of classification of tunnel by traffic performance, tunnel grade, the volume of traffic, fraction of HGV, rules or regulations for transports of dangerous good through tunnel.

Development of a Three-Dimensional DNS Code for Study of Clean Agents -Two-Dimensional Simulation of Diluted Nonpremixed Counterflow Flames-

  • Park, Woe Chul;Hamins, A.
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.18-23
    • /
    • 2002
  • A mixture fraction formulation is used to numerically simulate the structure of diluted axisymmetric methane-air nonpremixed counterflow flames. The effects of global strain rate and gravity wert! investigated and results were compared. Fuel of a mixture of 20% methane and 80% nitrogen by volume and oxidizer of pure air at low and moderate global strain rates $a_g= 20, 40, 80 s^{-1}$ in normal and zero gravity were computed. It is shown that the numerical method is capable of predicting the structure of counterflow flames in normal and microgravity environments at low and moderate global strain rates.

슬러리 충전 고성능 섬유 보강 시멘트 복합체의 역학적 성능 (Mechanical Performance of Slurry Infiltrated High Performance Fiber Reinforced Cementitious Composite)

  • 김현욱;이창준
    • 한국건축시공학회지
    • /
    • 제17권2호
    • /
    • pp.167-174
    • /
    • 2017
  • 고비율의 고로슬래그를 사용한 슬러리 충전 고성능 섬유보강 시멘트 복합체(SI-HPFRCC)의 역학적 성능을 평가하였다. SI-HPFRCC 실험체 제작을 위해 hooked-end 형의 강섬유를 6.4% 사용하였다. 재령에 따른 압축강도 및 압축인성과 휨강도 및 휨인성 실험을 통해 SI-HPFRCC의 역학적 성능을 평가하였다. 또한 섬유보강 효과를 평가하기 위해 SI-HPFRCC 실험체 제작에 사용된 슬러리 매트릭스의 압축강도 및 휨강도를 측정하였다. 실험결과 SI-HPFRCC의 휨거동이 재령에 따라 취성이 증가함을 확인하였다. 압축거동의 경우에도 재령에 따른 취성 증가를 볼 수 있었으나 그 정도는 미미하였다. 강도측면에서 볼 때 SI-HPFRCC는 슬러리 매트릭스에 비해 약 140~190%의 압축강도 증가와 440~500%의 휨강도 증가를 보였다.

사무소 건물 태양열급탕시스템의 LCC 최적화에 따른 에너지성능 변화 분석 (Energy Performance Variation of Solar Water Heating System by LCC Optimization in an Office Building)

  • 고명진;최두성;장재동;김용식
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.89-98
    • /
    • 2011
  • This study examined the energy performance according to the main design parameters of a solar water heating system for an office building using the life cycle cost (LCC) optimization simulations. The LCC optimization simulations of the system were conducted with TRNSYS and GenOpt employing the Hooke-Jeeves algorithm for cases where water temperature was $60^{\circ}C$ and $50^{\circ}C$. The results showed that for water temperature at $60^{\circ}C$ and $50^{\circ}C$ the global radiation incident on the collector could be decreased by 16.98% and 28.52%, collector useful energy gain could be decreased by 15.04% and 22.59%, energy to load from storage tank could be decreased by 10.86% and 18.06% and AH energy to load could be increased by 16.86% and 38.50% respectively compared to a non-optimized system. The annual average collection efficiency of the collector was increased by 0.88% for $60^{\circ}C$ and 2.78% for $50^{\circ}C$ because of increase of collector slope and decrease of the mass flow rate per collector area. The annual average efficiency of the system was increased by 1.74% and 3.47% compared to the basis system. However, the annual solar fraction of the system was decreased by 6.68% for $60^{\circ}C$ and 11.26% for $50^{\circ}C$ due to decrease of collector area and storage tank volume.

초고성능 섬유보강 콘크리트로 보강된 콘크리트의 계면 전단강도 결정을 위한 경사전단 실험 (Slant Shear Test for Determining the Interfacial Shear Strength of Concrete Strengthened with Ultra-High Performance Fiber Reinforced Concrete)

  • 임우영;홍성걸
    • 콘크리트학회논문집
    • /
    • 제28권6호
    • /
    • pp.637-646
    • /
    • 2016
  • 이 연구에서는 강섬유 보강 초고성능 콘크리트(Ultra-high performance fiber reinforced concrete, 이하 UHPFRC)로 보강된 콘크리트 계면에서의 전단강도 평가를 위한 경사전단실험을 수행하였다. 실험변수는 면처리 유무와 콘크리트 강도, 그리고 UHPFRC의 강섬유 혼입률이다. 콘크리트의 계면은 숏블라스팅으로 면처리되었다. 실험결과, 숏블라스팅으로 면처리된 실험체의 계면 전단강도는 매끄러운 표면을 가진 실험체의 부착강도에 비해 매우 크게 나타났으며, 거친면을 만들기 위한 숏블라스팅 방법은 매우 효과적인 방법인 것으로 나타났다. 숏블라스팅으로 표면처리를 할 경우, 전단마찰 철근이 없더라도 콘크리트 계면에서 저항하는 전단강도는 현행 기준에서 제시하고 전단강도 상한값을 초과하는 것으로 나타났다. 기존의 콘크리트와 UHPFRC 사이의 전단마찰 설계는 전단마찰 철근의 유무와 상관없이 현행 콘크리트 구조기준을 사용해도 무방할 것으로 판단된다. 다만, 면처리를 하지 않은 경우에는 적절한 전단 보강재가 추가 설치하여야 할 것이다.

순환골재를 사용한 강섬유보강 콘크리트보의 구조 성능 평가 (Structural Performance Evaluation of Steel Fiber-Reinforced Concrete Beams with Recycled Coarse Aggregates)

  • 신재린;김우석;백승민;강현구;곽윤근
    • 콘크리트학회논문집
    • /
    • 제27권3호
    • /
    • pp.215-227
    • /
    • 2015
  • 본 연구에서는 순환골재를 사용한 강섬유보강 콘크리트보의 전단거동을 알아보기 위하여 순환골재 치환율은 30 %로 고정하고, 전단경간비(a/d = 2, 3, 4), 인장철근비(${\rho}=0.8$, 1.27 %) 및 강섬유 혼입율($V_f=0$, 0.5, 0.75, 1%)을 변수로 한 총 24개의 강섬유보강 콘크리트보를 만들어 실험하였다. 또한 순환골재를 사용한 강섬유보강 콘크리트보의 전단강도를 여러 연구자들의 제안식과 비교 분석하였다. 즉, 순환골재를 사용한 강섬유보강 콘크리트보의 전단거동에 따른 전단내력을 분석하고, 강섬유보강 전단강도 제안식과 실험값을 비교하여 순환골재를 사용한 강섬유보강 콘크리트보의 사용가능성을 평가하고자 하였다. 대부분의 실험값이 제안식에 의한 이론값보다 높게 나타나 순환골재를 사용한 강섬유보강 콘크리트보를 구조부재로 사용하여도 무방하다고 판단된다.