• Title/Summary/Keyword: Forced ventilation

검색결과 145건 처리시간 0.022초

일정 열유속의 열원을 갖는 사각공간의 혼합대류 열전달 (Heat transfer of Mixed convection in rectangular space with constant heat flux)

  • 조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.552-558
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room numerical simulation with a standard k-$\varepsilon$model was carried out. In the present study the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with a downward angle depresses recirculation flow causing a strong stream in the wider space of the room Ventilation and removal of the released heat are promoted with this pattern, There is a possibility of local extreme heating at the upper surface of the engine when supply and exhaust ports of air are in bilateral symmetry.

  • PDF

Effects of different Diaphragm Breathing Methods on the Diaphragm Thickening Ratio and Pulmonary Function in Young Adults

  • Ha, Tae-Won;Lee, Myung-Mo
    • 대한물리의학회지
    • /
    • 제14권1호
    • /
    • pp.25-33
    • /
    • 2019
  • PURPOSE: This study examined the effective impact of self and resistive and ultrasound-biofeedback diaphragm breathing on the pulmonary function and diaphragm thickening ratio of young adults. METHODS: Thirty normal adults were assigned randomly to three experimental groups (self- diaphragm breathing (n=9), resistive-diaphragm breathing (n=11), ultrasound-biofeedback diaphragm breathing (n=10)). Each group participated for 15 minutes for times with a two minute rest between two sets. The subjects were assessed using the pre- and post- diaphragm thickening ratio and the pulmonary function (forced vital capacity, forced expiratory volume at one second, maximal voluntary ventilation, and respiratory rate) on the thirty subjects. A paired t-test was to determine the difference between before and after the experiment in each group of diaphragm breathing before and after the exercises. One-way ANOVA was used to determine the differences between the groups. RESULTS: The forced vital capacity and maximal voluntary ventilation measurements revealed a significant difference in the resistive-diaphragm breathing group than the other two groups. On the other hand, there was no significant difference between the self-diaphragm breathing and ultrasound-biofeedback breathing groups. CONCLUSION: The resistive-diaphragm breathing group showed greater improvement in the pulmonary function than the other two groups. Therefore, resistive-diaphragm breathing will improve the pulmonary function on normal young adults.

옥내저탄장 기류 흐름 및 환기량 분석을 통한 내부 유동 평가 (Evaluation of Internal through Analysis of Airflow and Ventilation of Coal Storage Shed)

  • 조현정;이진홍
    • 환경영향평가
    • /
    • 제31권5호
    • /
    • pp.334-342
    • /
    • 2022
  • 대기환경보전법이 강화되면서 야외저탄장을 옥내화 함으로써 외부로 날리는 비산먼지는 감소했지만, 저탄장에서 발생하는 석탄 비산먼지와 유해물질들을 단순히 격리함으로서 이러한 물질들이 내부에 축적되어 또 다른 문제를 야기할 수 있다. 본 연구는 이를 해결하기 위해 운영 중인 옥내 저탄장을 선정하여 내부 기류 흐름 양상과 환기량을 분석하였다. 옥내저탄장 내부 기류는 전반적으로 지형적으로 산 쪽에 접한 남서쪽으로 이동하는 경향을 보였다. 그리고 바다와 접한 북쪽 루버에서는 해풍에 의한 기류가 유입되고 있었다. 옥내저탄장 내부로 유입되는 총 유량은 918,691m3/h, 시간당 자연환기 횟수는 0.6회로 나타났다. 연구 결과를 바탕으로 내부 기류가 집중되는 위치에 강제 환기장치를 설치하는 것을 제안한다.

시설내 공기순환이 참외 발효과 발생에 미치는 영향 (Effect of Air Circulation in Greenhouse on Development of Fermented Fruits in Oriental Melon)

  • 신용습;연일권;배수곤;최성국;최부술
    • 생물환경조절학회지
    • /
    • 제10권1호
    • /
    • pp.23-29
    • /
    • 2001
  • 저온기 참외 시설재배시 시설내 공기흐름의 촉진이 발효과 발생 경감에 미치는 효과를 구명하기 위하여 하우스에 공기순환 및 환기팬을 설치하여 착과 5일 후인 4월 6일부터 6월 29일까지 비 오는 날을 제외한 모든 날의 09시 30분부터 15분간 처리 후 15분간은 정지시키는 방법으로 17시까지 가동하여 관행(권취식환기)과 비교 시험한 결과 작물체 부위의 풍속은 무처리는 0.06~0.08m.s$^{-1}$, 환기팬은 0.24~0.32m.s$^{-1}$, 공기 순환기는 0.60~0.72m.s$^{-1}$였다. 무처리에 비하여 공기순환 처리에서 엽장, 엽폭 등 생육은 처리간 차리가 없었으나 일비액량은 공기순환처리에서 월등히 증가하였다. 무처리에 비하여 공기순환 처리에서 발효과율이 유의하게 감소하였으나 환기팬처리와는 큰 차이가 없었다.

  • PDF

아트리움을 이용한 자연환기 활성화 방안에 관한 사례 연구 (An Application Study on a Strategy to Promote Natural Ventilation at an Atrium Building)

  • 신선준;이승연;조진균;한수곤;홍민호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.540-545
    • /
    • 2008
  • An atrium has great potential in natural ventilation aided by buoyance effect. Architectural design of an atrium is very critical to maximize the effect. However, it is not easy of an atrium to have optimum shape for natural ventilation, from the aesthetic and economic point of view. Admitting this condition, we suggested a strategy to promote natural ventilation, which can be adopted only with small design change. At first, we installed BIPV on the top of an atrium to strengthen buoyancy effect, and combine forced ventilation by low pressure fan. To evaluate the performance of the measure, CFD simulation and Energy-Airflow analysis were achieved.

  • PDF

제3종 하이브리드 환기시스템을 적용한 공동주택의 환기성능 예측 (A Prediction of Hybrid Ventilation System Performance in Apartment House)

  • 황지현;오창용;김무현
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.541-548
    • /
    • 2006
  • A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, $120m^3/h$. As the results, residents feel comfortable thermally for $60m^3/h$. In the case of $120m^3/h$, however, residents feel uncomfortable both thermally and in air currents. In this study the energy saving for space heating is also an important factor. In the case of whole region with $180m^3/h$, residents feel comfortable at each region of the model apartment. It is shown that this hybrid ventilation system is possible method for the apartment house.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • 유통과학연구
    • /
    • 제17권7호
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

지하철 환기구 개선 방안에 관한 연구 (A Study on Subway ventilation improve a program)

  • 최성호;최순기;손영진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1970-1974
    • /
    • 2010
  • This paper is how to improve contaminated air by the pollutant from vehicles through ventilators and entrance at the underground station. We are looking for the environment management to take care of customers. There is two ventilation systems. One is natural ventilation system, the other is forced ventilation system. Usually, subway ventilators were installed low on the sidewalk. There are lots of craps on the ventilators, so these things interrupt influx of outside air. But the gas from the vehicles comes into the station through entrance. There is lots of noise while ventilations run. So we install the supply air vents away from the road for the customers. If it's difficult, we cover around the ventilator with clear plastic plates more than 2M heights. We also install silencer on the ventilators. We install the air curtains on the entrances to prevent dust from outside. Seoul Metropolitan has a plan to make 60M deep underground road. To improve underground road air quality, ventilators should be installed that consider the above information.

  • PDF

PIV 속도장 측정기법을 이용한 공장 실내환기 개선방안 연구 (Improvement of Natural Ventilation in a Factory Building Using a Velocity Field Measurement Technique)

  • 임희창;김형범;이상준
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1427-1435
    • /
    • 2001
  • Air movement in wokplaces, whether resulting from a forced ventilation system or naturally occurring airflow, has a significant impact on occupational health. In a huge shipbuilding factory building, typical harmful factors such as fume or vaporized gas from welding and cutting of steel plates, and dusts from grinding give unpleasant feeling. From field data survey, the yearly dominant, wind directions for the shipbuilding factory building tested were northwest, northeast and southeast Among the three wind directions, the ventilation improvement was the worst for the northeastern wind. This study was focused on location of the opening vents in order to utilize the natural ventilation effectively. Instantaneous velocity fields inside the 1/1000 scale-down factory building model were measured using a 2-frame PIV system. The factory building model was embedded in an atmospheric boundary layer simulated in a wind tunnel. The modified vents improve the internal Ventilation flow with increasing the flow speed more than two times, compared with that of present vents.

공동주택 하이브리드(Hybrid) 환기시스템의 성능예측 (A Prediction of Hybrid Ventilation System Performance in Apartment House)

  • 황지현;오창용;최홍원;김무현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.33-38
    • /
    • 2005
  • A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, 120 $m^3/h$. As the results, residents feel comfortable thermally and in air flow conditions for 60 $m^3/h$. But the case of 30 $m^3/h$ shows 1100ppm of $CO_2$ concentration due to the deficient of air flow rate. In the case of 120 $m^3/h$, however, residents feel uncomfortable thermally and in air currents. In this study the energy saving for space heating is also an important factor. A detailed prediction for more complicated whole apartment space will be investigated in the future.

  • PDF