• 제목/요약/키워드: Force measuring

검색결과 948건 처리시간 0.032초

원자현미경을 이용한 생체물질의 접착력 측정기술 개발 (Novel measuring technique for biological adhesion forces using AFM)

  • 김성주;문원규;전종협
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.641-644
    • /
    • 2005
  • The study on the interaction forces of some biological materials is important to understanding biological phenomena and their application to practical purpose. This paper introduces a measuring technique for biological adhesive forces using the AFM(Atomic Force Microscope). Since no standardized thesis on adhesive forces exist, the adhesive forces is defined as adhesive forces against a hardened surface of biological materials. To grant the results are meaningful, which is based on the understanding the surface characteristics of biological materials using the AFM, a nominal value of average adhesive force per unit area should be measured. Therefore the modified AFM probe with small micro glass bead was proposed so that it can guarantee the required contact area for measuring the average adhesive forces. A pyrex glass substrate with circular patterns, which was fabricated by micromachining technique, is introduced in order to controll the contact area. The two types of mussel adhesive proteins, Celltak and recombinant-MGFP5, were tested by the proposed measuring method. The test results show that the adhesive force of the mussel adhesive proteins can be reliably measured by use of this method.

  • PDF

BUILD-UP 힘측정 시스템의 출력거동 (Output Behavior of Build-Up Force Measuring System)

  • 강대임;송후근;홍창선
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2194-2205
    • /
    • 1995
  • In order to reduce the systematic error of a build-up system, we have proposed a new test procedure in which all force transducers in a build-up system are rotated by 90.deg. with a base platen fixed on a force standard machine. The setting positions of force transducers on the output of a build-up system were investigated using an orthogonal array. The effects of the parallelism of a build-up system and of the bending moment sensitivity of a force transducer were considered. The experimental results show that the setting position of the base platen hardly affects the output of the build-up system, but the setting positions of force transducers affects it strongly. It reveals that the new test procedure reduces effectively the systematic error of a build-up system.

Monitoring of tension force and load transfer of ground anchor by using optical FBG sensors embedded tendon

  • Kim, Young-Sang;Sung, Hyun-Jong;Kim, Hyun-Woo;Kim, Jae-Min
    • Smart Structures and Systems
    • /
    • 제7권4호
    • /
    • pp.303-317
    • /
    • 2011
  • A specially designed tendon, which is proposed by embedding an FBG sensor into the center king cable of a 7-wire strand tendon, was applied to monitor the prestress force and load transfer of ground anchor. A series of tensile tests and a model pullout test were performed to verify the feasibility of the proposed smart tendon as a measuring sensor of tension force and load transfer along the tendon. The smart tendon has proven to be very effective for monitoring prestress force and load transfer by measuring the strain change of the tendon at the free part and the fixed part of ground anchor, respectively. Two 11.5 m long proto-type ground anchors were made simply by replacing a tendon with the proposed smart tendon and prestress forces of each anchor were monitored during the loading-unloading step using both FBG sensor embedded in the smart tendon and the conventional load cell. By comparing the prestress forces measured by the smart tendon and load cell, it was found that the prestress force monitored from the FBG sensor located at the free part is comparable to that measured from the conventional load cell. Furthermore, the load transfer of prestressing force at the tendon-grout interface was clearly measured from the FBGs distributed along the fixed part. From these pullout tests, the proposed smart tendon is not only expected to be an alternative monitoring tool for measuring prestress force from the introducing stage to the long-term period for health monitoring of the ground anchor but also can be used to improve design practice through determining the economic fixed length by practically measuring the load transfer depth.

AFM을 이용한 나노스케일 힘의 정량적 측정 (Quantitative Measurement of Nano-scale Force using Atomic Force Microscopy)

  • 정구현
    • Tribology and Lubricants
    • /
    • 제28권2호
    • /
    • pp.62-69
    • /
    • 2012
  • Atomic force microscopy (AFM) has been widely utilized as a versatile tool not only for imaging surfaces but also for understanding nano-scale interfacial phenomena. By measuring the responses of the photo detector due to bending and torsion of the cantilever, which are caused by the interactions between the probe and the sample surface, various interfacial phenomena and properties can be explored. One of the challenges faced by AFM researchers originates in the physics of measuring the small forces that act between the probe of a force sensing cantilever and the sample. To understand the interactions between the probe and the sample quantitatively, the force calibration is essential. In this work, the procedures used to calibrate AFM instrumentation for nano-scale force measurement in normal and lateral directions are reviewed.

지면 반력 분석을 위한 압력판 시스템 개발에 관한 연구 (A study on the development of the force-platform system for ground reaction force analysis)

  • 최혁재;이언주;김문화;장동식
    • 대한인간공학회지
    • /
    • 제14권2호
    • /
    • pp.75-85
    • /
    • 1995
  • The purpose of this study is to develop a force-platform system suitable for real situations in industry. The developed system is a 3-axis measurement type. It consists of force-transmission, force measuring circuit, and the software that analyzes the measured force. The force-transmission transmits forces to 3 axes, which has a physical structure to minimize the interference among those axes. Force measuring circuit consists of DSP (digital signal processor) for flexible disposal of change of measurement algorithm, elimination of noise and maintenance of precision. The functions of the software are the calibration which revises the measurement error occuring during data acquisition, and various analyses of forces. The result of the experiment shows that the developed system has about 1% measurement error, is stable for repeated experiments, and is not effected by temperature change.

  • PDF

한국형 고속철도차량의 차륜/레일 작용력 측정 및 주행안전성 평가 (Evaluation of running safety and measuring wheel/rail force for korean high speed railway vehicle)

  • 함영삼;오택열;백영남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.507-512
    • /
    • 2003
  • The railroad is a means of large transportation which has many latents such as a safety and a regularity. That is a results from various confidential performance tests and evaluations of the system. The railroad system consist of various subsystems - vehicle, power supply, signal, communications, track structures, operations, etc. Among them, as an item of safety evaluation there is a measurement of wheel/rail force, so called a measurement of derailment coefficient. This is a very important item because a derailment of a train will bring about a big accident. Especially it is more important in high speed rail of which operation speed is over two times as fast as existing rail. In this paper, it is introduced to preprocess the wheelset for measuring wheel/rail force of high speed rail, such as to treat a measuring wheelset, its finite element analysis, adhesion of strain gauges and static toad test, running test result of main line.

  • PDF

한국형 고속전철 집전장치 접촉력 계측에 관한 연구 (A Study on the Measurement of Contact Force of Pantograph of Korean High Speed Train)

  • 서승일;조용현;박춘수;목진용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1453-1457
    • /
    • 2003
  • The pantograph for Korean High Speed Train was developed by home-grown technology. In this study, a system to measure the contact force of pantograph is developed and installed on the prototype high speed train, Contact force prevents the pantograph from separating from the catenary. However, excessive contact force causes rapid erosion of catenary. The contact force can be divided into lift force and spring force. Contact force measurement is conducted while the train runs on the test track. The lift force is measured by the load cell on the roof separately and combined with the spring force of pan-head to form the contact force. Measured results show that the contact force of the pantograph of Korean High Speed Train is below the upper limit regulated by the high speed train standards. The contact force measuring system provides data to evaluate safety of the catenary system.

  • PDF

3 분력 힘 센서를 이용한 CMM 용 접촉식 프로브의 개발에 관한 연구 (A Study of Development for Contact CMM Probe using Three-Component Force Sensor)

  • 송광석;권기환;박재준;조남규
    • 한국정밀공학회지
    • /
    • 제20권8호
    • /
    • pp.101-107
    • /
    • 2003
  • A new mechanical probe for 3-D feature measurement on coordinate measuring machines (CMMs) is presented. The probe is composed of the contact stylus and the three-component force sensor. With the stylus mounted on the force sensor, the probe can not only measure 3-D features, but also detect contact force acting on the stylus tip. Furthermore, the probing direction and the actual contact position can be determined by the relationship among three components of contact force to be detected. In this paper, transformation matrix representing the relationship between the external force acting on the stylus tip and the output voltages of measurement gauges is derived and calibrated. The prototype of probe is developed and its availability is investigated through the experimental setup for calibration test of the probe. A series of experimental results show that the proposed probe can be an effective means of improving the accuracy of touch probing on CMM.

상지재활로봇의 팔힘측정용 2축 힘센서 설계 (Design of a Two-Axis Force Sensor for Measuring Arm Force of an Upper-Limb Rehabilitation Robot)

  • 김갑순
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.137-143
    • /
    • 2015
  • This paper describes the design of a two-axis force sensor with two step plate beams for measuring forces in an upper-limb rehabilitation robot. The two-axis force sensor is composed of a Fz force sensor and a Ty torque sensor. The Fz force sensor measures the force applied to a patient's arm pushed by a rehabilitation robot and the force of patient's arm. The Ty torque sensor measures the torque generated by a patient's arm motion in an emergency. The structure of sensor is composed of a force transmitting block, two step plate beams and two fixture blocks. The two-axis force sensor was designed using FEM (Finite Element Method), and manufactured using strain-gages. The characteristics test of the two-axis force sensor was carried out. as a test results, the interference error of the two-axis force sensor was less than 1.24%, the repeatability error of each sensor was less than 0.03%, and the non-linearity was less than 0.02%.