• Title/Summary/Keyword: Force loading

Search Result 1,290, Processing Time 0.035 seconds

Design and analysis of tactile sensor for tri-axial force measurement using FEM (유한요소해석을 이용한 3축 힘 촉각센서 설계 및 해석)

  • Cho, Woon-Ki;Kim, Jong-Ho;Kang, Dae-Im;Lee, Ouk-Sub
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.865-870
    • /
    • 2001
  • A sensing element for tri-axial force measurement, unit sensor of tactile sensor, was designed and evaluated by using finite element method (ANSYS). The sensor has a maximum force range of ${\pm}10$ N in the x, y, and z direction. Optimal cell structures and piezoresistor positions were determined by the strain distribution obtained from finite element analysis. Finally three Wheatstone birdge circuits were arranged and verified by $F_x$, $F_y$, and $F_z$ loading conditions. In addition, in case of sensing element subjected to thermal loading, the outputs of three bridge circuits were also evaluated.

  • PDF

An Experimental Study on the Dynamic Coefficient According to the Source Positions in Externally Pressurized Air-lubricated Journal Bearing with Two Row Sources (2열 외부가압 공기 저어널 베어링에서 급기구 위치에 따른 동적계수에 관한 실험적 연구)

  • 이종렬;이준석;성승학;이득우
    • Tribology and Lubricants
    • /
    • v.17 no.6
    • /
    • pp.476-481
    • /
    • 2001
  • This paper has been presented the hydrodynamic effect by the journal speed, eccentricity and source positions in order to overcome the defects of air bearing such as low stiffness and damping coefficient. Choosing the two row source position of air bearing is different from existed investigations in the side of pressure distribution of air film because of the high speed of journal and the wedge effects by the eccentricity. These optimal chooses of the two row source positions enable us to improve the performance of the film reaction force and loading force as making the high speed spindle. In this paper, The pressure behavior in theory of air film according to the eccentricity of journal and the source positions analyzed. The theoretical analysis have been identified by experiments. The results of investigated characteristics may be applied to precision devices like ultra-precision grinding machine and ultra high speed milling.

A Expermental Study on the Dynamic Coefficients according to the Source Positions in Externally Pressurised Air-lubricated Journal Bearing with Two Row Sources (2열 외부가압 공기 저어널 베어링에서 공기 급기구 위치에 따른 동적계수에 관한 실험적 연구)

  • 이종렬;이준석;성승학;이득우
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.231-235
    • /
    • 2001
  • This paper has been presented the dynamic effect by the journal speed. eccentricity and source positions in order to overcome the defects of air bearing such as low stiffness and damping coefficient. Choosing the two row source position of air bearing is different from previous investigations in the side of pressure distribution of air film by the wedge effects. These optimal chooses of the two row source positions enable us to improve the performance of the film reaction force and loading force as making the high speed spindle. The results of investigated characteristics may be applied to precision devices like ultra-precision grinding machine and ultra high speed milling.

  • PDF

Loading Rate Effect on the Lateral Response of H-Shape Steel Column (재하속도가 H-형강 기둥부재의 횡방향 거동에 미치는 영향)

  • Park, Minseok;Kim, Chul-Young;Han, Jongwook;Chae, Yunbyeong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.637-644
    • /
    • 2021
  • Dynamic response of structures can be evaluated experimentally by conducting cyclic loading tests. It has been known that steel materials are rate-dependent and the lateral response of a structure is significantly affected by the presence of axial force. However, the rate-dependency of steel column structures subjected to both axial and lateral loads has not been sufficiently studied yet due to the difficulty of controlling the axial force in a real-time manner during test. This study introduces an advanced way to apply the axial load in real-time to a column specimen using the adaptive time series (ATS) compensator and the flexible loading beam (FLB), where the H-shape steel columns made of SS275 are used for monotonic and cyclic loading tests with various loading rates with axial loads. The lateral strength and post-yield response of the steel columns are compared for each of monotonic and cyclic loading tests. The estimating equation of yield stress of various strain rate has proposed and finite element analysis were performed for comparison.

The Size of Crowd Pressure According to Loading Patterns (가력유형별 군중하중의 크기에 관한 실험적 연구)

  • Kim, Jin-Sik;Shin, Yun-Ho;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.128-129
    • /
    • 2016
  • This study is to categorize the loading of multiple persons on a vertical building elements into three types to test the size of crowd pressure under each loading patterns. The loading patterns is divided under the combination of loading method and loading persons. The loading method is categorized into the method of instantaneous loading of hand on a force plate and the method of continuous loading. The loading persons has been composed of 1~5 persons under the loading patterns. The loading patterns is also divided into lateral loading, longitudinal loading, and agglomeration loading. The subject group has been composed of 12 males in 20s. The load measurement device(size 1800×600×36mm, capacity 20kN, rigidity 28kN/cm) has been designed and manufactured directly. To eliminate the difference of individual, the size of crowd pressure has been converted into the strength to weight ratio (maximum load/weight) for computation. The strength to weight ratio in lateral loading was about 0.91 under instantaneous loading and about 0.47 under continuous loading. The strength to weight ratio in longitudinal loading was about 0.65 under instantaneous loading and about 0.36 under continuous loading. The strength to weight ratio in agglomeration loading was about 0.65 under instantaneous loading and about 0.36 under continuous loading.

  • PDF

Effects of Fatigue Induction on Ground Reaction Force Components, Postural Stability, and Vertical Jump Performance in Taekwondo Athletes

  • Hyun, Seung-Hyun;Kim, Young-Pyo;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.143-151
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effect of fatigue induction on ground reaction force (GRF) components, postural stability, and vertical jump performance in Taekwondo athletes. Method: Ten Taekwondo athletes (5 men, 5 women; mean age, $22.30{\pm}2.62years$; mean height, $174.21{\pm}9.20cm$; mean body weight, $67.28{\pm}12.56kg$) participated in this study. Fatigue was induced by a short period of strenuous exercise performed on a motorized treadmill. The analyzed variables included vertical jump performance, static stability (mediolateral [ML], center of pressure [COP], anteroposterior [AP] COP, ${\Delta}COPx$, ${\Delta}COPy$, and COP area), postural stability index values (ML stability index [MLSI], AP stability index [APSI], vertical stability index [VSI], dynamic postural stability index [DPSI]), and GRF components (ML force, AP force, peak vertical force [PVF], and loading rate). To analyze the variables measured in this study, PASW version 22.0 was used to calculate the mean and standard deviation, while a paired t-test was used to evaluate the pre- versus post-fatigue results. Pearson's correlation coefficients among variables were also analyzed. The statistical significance level was set at ${\alpha}$ = .05. Results: Vertical jump performance decreased significantly after the induction of fatigue, while AP COP, ${\Delta}COPx$, COP area, APSI, VSI, and DPSI increased significantly. PVF and loading rate increased significantly after the induction of fatigue, while the postural stability variables (AP COP, ${\Delta}COPy$, COP area, APSI, VSI, DPSI) were similarly correlated with GRF components (PVF, loading rate) after fatigue was achieved (r = .600, $R^2$ = 37%). Conclusion: These results suggest that the induction of fatigue can decrease postural stability and exercise performance of Taekwondo athletes during training and competition sessions.

AFM fabrication of oxide patterns on 4H-SiC surface (4H-SiC 표면에서 AFM의 산화 패턴 제작)

  • Jo, Yeong-Deuk;Bahng, Wook;Kim, Sang-Cheol;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.64-64
    • /
    • 2009
  • Atomic force microscopy (AFM) fabrication of oxide patterns is an attractive technique for nanoscale patterns and related device structures, SiC exhibits good performance in high-power, high-frequency, and high-temperature conditions that is comparable to the performance of Si. The AFM fabrication of oxide patterns on SiC is important for electronic applications. However, there has not been much reported investigations on oxidation of SiC using AFM. We achieved the local oxidation of 4H-SiC using the high loading force of ~100 nN, although the oxidation of SiC is generally difficult mainly due to the physical hardness and chemical inactivity. All the experiments were performed using atomic force microscopy (S.I.S. GmbH, Germany) with a Pt/Ir-coated Si tip at ~40% humidity and room temperature. The spring constant and resonance frequency of the tip were around ~3 N/m and ~70 kHz. We fabricated oxide patterns on n-type 4H-SiC ($\sim10^{19}/cm^3$) and n-type Si ($\sim1.9\times10^{16}/cm^3$). In summary, we demonstrated that the oxide patterns can be obtained over the electric field of ${\sim}\times10^7 V/cm$ and the high loading force using the tip as a cathode. The electric field transports the oxyanions (OH-) to the positively biased surface.

  • PDF

Sinking and fit of abutment of locking taper implant system

  • Moon, Seung-Jin;Kim, Hee-Jung;Son, Mee-Kyoung;Chung, Chae-Heon
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • STATEMENT OF PROBLEM. Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE. In this study, Bicon$^{(R)}$ Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS. 10 Bicon$^{(R)}$ implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS. It was evident, that the amount of abutment sinking in Bicon$^{(R)}$ Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at $0.45{\pm}0.09\;mm$. CONCLUSION. Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.

Evaluation of Applicability of Cable Force Monitoring System of Cable-stayed Bridge by Field Loading Test (재하시험을 통한 사장교의 케이블 장력 모니터링 시스템의 적용성 평가)

  • Kim, Jeong-Hoon;Song, Jae-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.205-213
    • /
    • 2009
  • This study was planned to develop monitoring system of cable force to resolve cable force of cable-stayed bridge efficiently in a long-term plan. In the proposed monitoring system, firstly data are sampled from real-time acceleration record, secondly these sampled data are frequency analyzed by using the FFT(Fast Fourier Transform) algorism and lastly the analyzed results are averaged and generalized. For evaluating the applicability of this monitoring system, field loading test has performed in real cable-stayed bridge. In comparison with cable force by field manual calculation and cable force of monitoring system by semi-automatic calculation, the difference of calculated cable forces has within 1% error range and it is acceptable range. Additionally within negligible 5% error range of difference has occur between field manual calculation and monitoring system by automatic calculation. so monitoring system in this study has been verified to be reliable.

The Loading History Effect on the Track-bridge Interaction (궤도-교량의 상호작용에 대한 하중이력의 영향)

  • Yun, Kyung-Min;Han, Sang-Yun;Hwang, Man-Ho;Kim, Hae-Gon;Lim, Nam-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3156-3159
    • /
    • 2011
  • In case of the continuous welded rail(CWR) track is supported by the railway bridge, the additional axial force is occurred in the CWR due to the track-bridge interaction. In the various design codes such as Korean code, European code, UIC code, etc, three important loads(temperature variation in the bridge-deck, braking/acceleration and the bending of the bridge-deck resulted from the passing train) are treated as the independent loading case. In other words, the additional axial force can be obtained by summing up the three different values calculated by the three independent analysis. However, this analysing method may have an error because the behavior of the longitudinal resistance between the rail and the bridge-deck is under the highly nonlinear. Therefore, in order to exactly analyse the track-bridge interaction, nonlinear loading history and the change of the longitudinal resistance owing to the loading history must be considered in the analysis process. In this study, the loading history effect on the track-bridge interaction is investigated considering the resonable combination of three loads and the longitudinal resistance change.

  • PDF