• Title/Summary/Keyword: Focal length

Search Result 372, Processing Time 0.035 seconds

Simple Analysis of the Properties of Condenser Lens 1 in SEM (SEM에서 접속 렌즈 1 의 특성에 대한 간단한 분석)

  • Lim, Sun-Jong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.5
    • /
    • pp.705-709
    • /
    • 2010
  • It is quite complex to draw the geometry of electron trajectories in electron optics because such trajectories have various aberrations that cannot be easily calculated. However, if we need to know roughly the geometry, the focal length and the principal planes in order to understand the properties of column, a simple numerical solution can be a useful method. We are developing the electron beam machining system based on SEM. In this paper, we show rough geometry, focal length and principal planes by a numerical solution for electron lens I in our column. These results will be utilized in developing a simulation program for electron optics.

Camera Focal Length Measuring Method and 3-Dimension Image Correspondence of the Axial Motion Model on Stereo Computer Vision (3-Dimension 영상을 이용한 카메라 초점측정 및 동일축 이동 모델의 영상 정합)

  • 정기룡
    • Journal of the Korean Institute of Navigation
    • /
    • v.16 no.3
    • /
    • pp.77-85
    • /
    • 1992
  • Camera arrangement for depth and image correspondence is very important to the computer vision. Two conventional comera arrangements for stereo computer vision are lateral model and axial motion model. In this paper, using the axial motion stereo camera model, the algorithm for camera focal length measurement and the surface smoothness with the radiance-irradiance is proposed fro 3-dimensional image correspondence on stereo computer vision. By adapting the above algorithm, camera focal length can be measured precisely and the resolution of 3-dimensional image correspondence has been improved comparing to that of the axial motion model without the radiance-irradiance relation.

  • PDF

Design of focal length of Moire lens according to lens phase pattern (렌즈의 위상 패턴에 따른 무아레렌즈의 초점거리 설계)

  • Park, Sungwoong;Kim, Youngrok;Min, Sung-wook
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • fall
    • /
    • pp.144-145
    • /
    • 2021
  • Variable range of focal length of Moiré lens is designed to change the phase pattern, which is varifocal lens system using two thin layers with Moiré pattern and suitable to applied to AR/VR system because of the relatively simple structure, large aperture size, and wide variable range. We analyze the change of focal length region according to the phase pattern and verify the design to make the prototype patterns using DOE.

  • PDF

Digital imaging of film-based cephalograms using a digital camera (디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환)

  • Wang, Sung-Jin;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.448-457
    • /
    • 2004
  • As computer Programs for cephalometric analysis were developed in diagnosis & treatment planning, digital imaging of film-based cephalograms came to be needed. When a digital camera is used, a problem encountered the image distortion produced according to the focal length, which causes errors in indentifying landmarks. In addition, changes in the image size and compression ratio will inevitably produce a low quality image, causing errors in identifying landmarks. Hence. we have found the focal length producing the least image distortion when digital imaging the film-based cephalograms and the minimal digital camera setting which helps to identify the correct landmarks using the COOLPIX4500 digital camera (Nikon, Japan). The results were as follows The image distortion was minimized at a focal length of 16.4mm (79.4mm when converted into a 35mm film camera) when digital imaging the film-based cephalograms. When wide imaging, with a focal length of under IS.4mm, barrel distortion was found and when tole imaging. with a focal length of over 15.4mm pincushion distortion was found. The minimal digital camera setting was $2272{\times}1704$ pixel at normal (1/8) compression from which we can identify the correct landmarks at the same level as tracing the film-based cephalograms manually. As a result. when digital imaging the film-based cephalograms, using a COOLPIX4500 digital camera (Nikon, Japan), the focal length should be 16.4mm the pixel image size over $2272{\times}1704$, and the compression ratio over normal (1/8).

The Effect of Focal Length on Fuel Mixing And Combustion in One-focusing Oxygen Burner (일 초점 산소 버너의 초점 거리가 연료 혼합 및 연소에 미치는 영향)

  • Park, Kweon-Ha;Kim, Ju-Youn
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.814-819
    • /
    • 2011
  • An Oxy-fuel combustion has been studied in order to reduce exhaust emissions and fuel consumption. The flow and flame behaviors are analyzed with focal length variation in one-focussing oxygen burner introduced in this study. Oxygen is supplied into the center of the nozzle, methane fuel is into the outer nozzle of the center, and then oxygen is again supplied into the outer of the fuel nozzle. The test conditions are 5 focal lengths of 100mm to 500mm. The mixing behaviors and temperature distributions are analyzed. The result shows that the shorter the focal length is, the longer the mixing length becomes, and the flame width and length are the biggest in the case of 300mm.

Fabrication of the focal length and distortion measurement system (초점길이 및 왜곡수차 측정장치 제작)

  • 조현모
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.82-86
    • /
    • 1990
  • A camera type optical bench system equipped with a lens collimator and an image analyzer is fabricated to measure the equivalent focal length and distortion of lenses. This system is automatized by the computer which controls stepping motors. A nodal slide optical bench system equipped with an off axis reflective collimator is fabricated and improved by using rotating arms and air bearing system. distortion measurement on a wide angle lens using the camera method and the nodal slide method is reported. Defocusing error in the distortion measurement with the nodal slide optical bench is analyzed and improved by iteration method to search the correct image point.

  • PDF

LED Output Light Characteristic by Lens Eccentricity (LED Lens 의 이심률에 따른 출광 특성)

  • Kim, Young-Chul;Lyu, Jong-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1170-1173
    • /
    • 2012
  • We have investigated the LED lens eccentricity effect on light intensity distribution. For the purpose, we introduced an equation of focal length for paraboloid, and then made a comparative analysis of the theoretical result and 3-D simulation result.

A Simple Method for Determining Focal Distances Using Talbot Self-Images

  • Spires, Oliver;Sasian, Jose;Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.638-642
    • /
    • 2015
  • We present a simple method to determine the focal distances of lenses with the Talbot self-images. This method uses only one grating, and a priori knowledge of the period of the grating is replaced with a linear relation between the (de)magnified periods of the Talbot images and the lens-to-grating distance. A thick lens whose effective focal length is 500 mm was used to validate the method, and the focal distance of the converging beam was determined with the difference of 0.15% for the nominal focal distance of 521.9 mm. The determined period of the grating with the difference of 0.2% also supports the validation.

An Experimental Study on the Characteristics of Flux Density Distributions in the Focal Region of a Solar Concentrator (태양열 집광기의 초점 지역에 형성된 플럭스 밀도 분포의 특성)

  • Hyun, S.T.;Kang, Y.H.;Yoon, H.G.;Yoo, C.K.;Kang, M.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.31-37
    • /
    • 2002
  • This experimental study represents the results of an analysis on the characteristics of flux density distributions in the focal region of solar concentrator. The characteristics of flux density distributions are investigated to optimally design and position a cavity receiver. This deemed very useful to find and correct various errors associated with a dish concentrator. We estimated the flux density distribution on the target placed along with focal lengths from the dish vertex to experimentally determine the focal length. It is observed that the actual focal point exists when the focal length is 2.17 m. We also evaluated the position of flux centroid, and it was found that there were errors within 2 cm from the target center. The total integrated power of 2467 W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06 m radius.

Empirical Modeling of Lens Distortion in Change of Focal Length (초점거리 변화에 따른 렌즈 왜곡의 경험적 모델링)

  • Jeong, Seong-Su;Woo, Sun-Kyu;Heo, Joon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.1
    • /
    • pp.93-100
    • /
    • 2008
  • The parameters of lens such as focal length, focus, and aperture stop changes while shooting the scenes with zoom lens. Especially, zooming action dramatically changes the geometry of lens system that causes significant change of lens model. We investigated how the lens model changes while zooming in general shooting condition. Each parameters of lens model was estimated and checked whether they can be modeled well in the condition of auto-controlling focus, aperture and vibration reduction. In order to do this, calibration images were taken, modeled in different fecal length setting. And changing patterns of models were inspected to find out if there is some elements that have some particular pattern in changing with respect to focal length. The result showed us that although we didn't control the focus and aperture setting, there's specific changing patterns in radial and do-centering distortion. Especially, the strong linear correlation was found between coefficient of $r^2$ and focal length. It is expected that many parts of distortion can be eliminated without additional self calibration even if zoom operation is done when shooting the scenes if we know its fecal length and model of this coefficient.