• 제목/요약/키워드: Focal Zone

검색결과 71건 처리시간 0.026초

Numerical Study of a Novel Bi-focal Metallic Fresnel Zone Plate Having Shallow Depth-of-field Characteristics

  • Kim, Jinseob;Kim, Juhwan;Na, Jeongkyun;Jeong, Yoonchan
    • Current Optics and Photonics
    • /
    • 제2권2호
    • /
    • pp.147-152
    • /
    • 2018
  • We propose a novel bi-focal metallic Fresnel zone plate (MFZP) with shallow depth-of-field (DOF) characteristics. We design the specific annular slit patterns, exploiting the phase-selection-rule method along with the particle swarm optimization algorithm, which we have recently proposed. We numerically investigate the novel characteristics of the bi-focal MFZP in comparison with those of another bi-focal MFZP having equivalent functionality but designed by the conventional multi-zone method. We verify that whilst both bi-focal MFZPs can produce dual focal spots at $15{\mu}m$ and $25{\mu}m$ away from the MFZP plane, the former exhibits characteristics superior to those of the latter from the viewpoint of axial resolution, including the axial side lobe suppression and axial DOF shallowness. We expect the proposed bi-focal MFZP can readily be fabricated with electron-beam evaporation and focused-ion-beam processes and further be exploited for various applications, such as laser micro-machining, optical trapping, biochemical sensing, confocal sensing, etc.

Dichromated Gelatin 박막을 이용한 홀로그래픽 Zone Plate 제작 및 해석 (Fabrication of holographic zone plate using dichromated gelatin hologram)

  • 임용석;이영락;곽종훈;최옥식
    • 한국광학회지
    • /
    • 제8권1호
    • /
    • pp.19-25
    • /
    • 1997
  • Agfa 8E75HD 사진건판에서 얻은 dichromated gelatin(DCG) 박막에 구면파와 평면파를 간섭시켜 holographic zone plate(HZP)를 만들었다. DCG박막의 비서형적인 광학특성들을 고려하여 HZP의 이론식을 유도하였다. 이 이론식에 의한 HZP의 초점거리를 거리는 f. f/2, f/3, f/4, ... 였으며, 실험적으로도 평면파를 입사하여 6개까지의 해당 초점들을 관측하였다. 칼날 주사 방법으로 측정한 첫 번째 재생 초점 근처에서의 빔의 모양은 Gaussian 분포를 가짐을 확인하였다.

  • PDF

펨토초 레이저 리소그라피 기술을 이용한 Fresnel zone plate 제작 연구 (Fabrication of Fresnel zone plate with femtosecond laser lithography technology)

  • 손익부;노영철;고명진
    • 한국레이저가공학회지
    • /
    • 제14권2호
    • /
    • pp.13-16
    • /
    • 2011
  • We fabricated the Fresnel zone plate using femtosecond laser lithography-assisted micro-machining, which is a combined process of nonlinear lithography and wet etching. We investigated the focusing properties by launching a 632.8nm wavelength He-Ne laser beam into the zone plate. The spot size of the primary focal point was $27{\mu}m$ and the intensity of focal point was 0.565W/$cm^2$.

  • PDF

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • 한국임상수의학회지
    • /
    • 제39권3호
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

펨토초 레이저를 이용한 회절격자와 Fresnel Zone Plate 제작 및 광학적 분석 (Optical Analysis of Diffraction Grating and Fresnel Zone Plate Fabricated on Fused Silica Glass by a Femtosecond Laser)

  • 유진창;김진태;손익부
    • 한국정밀공학회지
    • /
    • 제27권3호
    • /
    • pp.18-26
    • /
    • 2010
  • Diffraction gratings with precise spatial periods of 2 ${\mu}m$ and 5 ${\mu}m$ have been fabricated by using a femtosecond laser which does not have limits on materials of micromachining and small thermal effects due to high peak power. Diffraction angle and diffraction efficiency of those were measured. Simulation results of diffraction angle and diffraction efficiency of the diffraction grating calculated with the parameters such as line width, depth, and spatial period of the fabricated gratings were compared with experimental results measured with a He-Ne laser. Besides these, Fresnel Zone Plates (FZPs) with focal distances of 50 mm and 25 mm were fabricated and focal distances of fabricated FZP were measured. Those experimental results for diffraction gratings and FZPs match well with experimental results.

The 29 May 2004 Offshore Southeast Coast of Korea Earthquake Sequence: Shallow Earthquakes in the Ulleung Back-arc basin, East Sea (Sea of Japan)

  • ;노명현
    • 지구물리
    • /
    • 제9권3호
    • /
    • pp.249-262
    • /
    • 2006
  • The 29 May 2004 offshore Uljin, Korea earthquake was predominantly thrust-faulting at a depth of approximately 12 (±2) km. The mainshock attained the seismic moment of M0 =5.41 (±1.87)  1016 N m (Mw = 5.1). The focal mechanism indicates a subhorizontal P-axis trending 264° and plunging 2°. The orientation of P- and T-axis is consistent with the direction of absolute plate motion generally observed within the plates, hence the cause of the May 29 shock is the broad-scale stress pattern from the forces acting on the downgoing slab along the Japan trench and inhibiting forces balancing it. The 29 May 2004 earthquake occurred along a deep seated (~12 km), pre-existing feature that is expressed on the surface as the basement escarpment along the western and southern slopes of the Ulleung basin. The concentrated seismicity along this basement escarpment suggests that this feature may qualify as a seismic zone - the Ulleung basement escarpment seismic zone (UBESZ).

  • PDF

전과정평가에 있어 확률론적 건강영향분석기법 적용 -Part I : 전과정평가에 있어 확률론적 위해도 분석기법 적용방안에 관한 연구 (Application of Probabilistic Health Risk Analysis in Life Cycle Assessment -Part I : A General Framework for Uncertainty and Variability Analysis of Health Risk in Life Cycle Assessment)

  • 최광수;박재성
    • 환경영향평가
    • /
    • 제9권3호
    • /
    • pp.185-202
    • /
    • 2000
  • Uncertainty and variability in Life Cycle Assessment(LCA) have been significant key issues in LCA methodology with techniques in other research area such as social and political science. Variability is understood as stemming from inherent variations in the real world, while uncertainty comes from inaccurate measurements, lack of data, model assumptions, etc. Related articles in this issues were reviewed for classification, distinguish and elaboration of probabilistic/stochastic health risk analysis application in LCA. Concept of focal zone, streamlining technique, scenario modelling and Monte Carlo/Latin Hypercube risk analysis were applied to the uncertainty/variability analysis of health risk in LCA. These results show that this general framework of multi-disciplinary methodology between probabilistic health risk assessment and LCA was of benefit to decision making process by suppling information about input/output data sensitivity, health effect priority and health risk distribution. There should be further research needs for case study using this methodology.

  • PDF

다초점 기능을 갖는 그래핀 전극 기반 적외선 프레넬 렌즈 (A Graphene-electrode-based Infrared Fresnel Lens with Multifocal Function)

  • 남국현;이종권
    • 한국광학회지
    • /
    • 제33권1호
    • /
    • pp.28-34
    • /
    • 2022
  • 그래핀 전극 아래에 놓인 다층 그래핀 존 플레이트로 구성된 적외선 프레넬 렌즈의 초점 성능을 전산모사를 통해 조사한다. 여기서 패턴된 다층 그래핀의 페르미 에너지 준위(EF)는 그 위에 놓인 그래핀 전극에 의해 조절된다. 4 ㎛에서 30 ㎛까지의 광대역 파장에서 유리 기판 위에 놓인 8층 그래핀 존 플레이트와 그래핀 전극의 반사도 대비비에 따른 프레넬 렌즈 효과를 분석하였다. 반사도와 반사도 대비비를 고려한 최적 파장인 8 ㎛ 입사파가 초점거리 240 ㎛인 프레넬 렌즈에 입사 시, 다층 그래핀의 EF가 0.4 eV에서 1.6 eV로 증가함에 따라 초점 세기가 4.3배, 그래핀 층수가 2층에서 8층으로 증가함에 따라 5.8배 강화되었다. 이를 통해 인가된 EF에 따라서 다중 초점(240 ㎛ 및 360 ㎛) 성능을 보이는 그래핀만으로 구성된 IR 프레넬 렌즈 구조를 초박형 렌즈 플랫폼으로 제안한다.

다이오드 레이저를 이용한 금속 표면 열처리 특성 (Characteristics of Metal Surface Heat Treatment by Diode Laser)

  • 최성대;정선환;김기만;양승철;김잠규
    • 한국기계가공학회지
    • /
    • 제6권3호
    • /
    • pp.16-23
    • /
    • 2007
  • An experimental investigation with diode laser system was carried out to study the effect of surface heat treatment on the die materials(SM45C, SKD11, SK3). The surface heat treatment characteristics of the laser beam are evaluated using hardness tests, optical microscopy, X-ray diffraction and energy dispersive X-ray spectroscopy(EDS). Results indicated that the beam size, focal length, feed rates are changed surface hardened characteristics. SM45C is higher hardness than other materials and composed to martensite grain at hardened zone, whereas other materials(SKD11, SK3)are low hardness than expected and composed to austenite and allayed martensite at hardened zone. The intensive X-ray diffraction patterns of (110)-(200)-(211) is detected hardened surface and the hardened surface distributed plenty of carbon density than metal zone.

  • PDF

Simulation of an X-ray Fresnel Zone Plate with Nonideal Factors

  • Chen, Jie;Fan, Quanping;Wang, Junhua;Yuan, Dengpeng;Wei, Lai;Zhang, Qiangqiang;Liao, Junsheng;Xu, Min
    • Current Optics and Photonics
    • /
    • 제4권1호
    • /
    • pp.9-15
    • /
    • 2020
  • Fresnel zone plates have been widely used in many applications, such as x-ray telescopes, microfluorescence, and microimaging. To obtain an x-ray Fresnel zone plate, many fabrication methods, such as electron-beam etching, ion-beam etching and chemical etching, have been developed. Fresnel zone plates fabricated by these methods will inevitably lead to some nonideal factors, which have an impact on the focusing characteristics of the zone plate. In this paper, the influences of these nonideal factors on the focusing characteristics of the zone plate are studied systematically, by numerical simulations based on scalar diffraction theory. The influence of the thickness of a Fresnel zone plate on the absolute focusing efficiency is calculated for a given incident x-ray's wavelength. The diffraction efficiency and size of the focal spot are calculated for different incline angles of the groove. The simulations of zone plates without struts, with regular struts, and with random struts are carried out, to study the effects of struts on the focusing characteristics of a zone plate. When a Fresnel zone plate is used to focus an ultrashort x-ray pulse, the effect of zone-plate structure on the final pulse duration is also discussed.