• Title/Summary/Keyword: Flux Profile Method

Search Result 48, Processing Time 0.033 seconds

Scanning System Method for Calculating Ion Flux in Plasma Etching Simulation (플라즈마 식각 시뮬레이션을 위한 스캔 방식의 이온 플럭스 계산 방법)

  • Shin, Sung-Sik;Yu, Dong-Hun;Gwun, Ou-Bong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.124-131
    • /
    • 2013
  • The most important thing in Plasma simulation is the etching process in which etch rate is calculated based on feature profile. Although there are various components to consider in calculating etch rate such as Ion Flux, Neutral, gas, and temperature, Addressing of this paper is limited to Ion Flux. This paper propose a scan method to compute Ion Flux faster for Plasma simulation. Also, this paper experiments and compares generally used Monte Carlo method and the proposed method based on gaussian and cosine distribution. Lastly, this paper proves that the proposed method can calculate accurate Ion Flux more efficiently than Monte Carlo method.

Flux Profile Method for Evaluating the thermal Efficiency of Green roof (Flux Profile Method를 적용한 옥상녹화의 열효율 성능 평가)

  • Kwon, You Jeong;Seo, YongWon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.320-320
    • /
    • 2022
  • 기후변화와 도시화로 인한 영향으로 도시의 폭우, 폭염을 비롯한 현상이 빈번하게 발생하고 있다. 특히 시가화 지역의 높은 불투수율은 도시홍수를 야기한다. 이러한 현상을 완화하기 위해 도시지역에서는 그린인프라와 저영향개발이 도입되고 있다. 그 중 지속가능한 발전을 위한 필수요소로 자리매김한 옥상녹화는 도시에 위치한 건물의 상층부와 내부의 온도를 낮춤으로써 에너지절감효과와 강우 시 빗물을 저류함으로써 우수유출 저감효과, 그리고 도시 공간 내 녹지도입으로 인한 이산화탄소 배출 저감 효과 등을 기대할 수 있다. 본 연구에서는 열섬현상완화와 유출 저감의 방안 중 하나인 옥상녹화(Green roof)의 효과를 정량적으로 평가하기 위해 콘크리트로 이루어진 동일한 제원의 실험동을 구축하고, 실험동 내외부의 온도, 습도, 강우, 풍속, 일사량 등의 기상자료를 측정할 수 있는 센서를 설치하였다. 각 실험동에서 측정된 기상요소를 Flux Profile Method를 적용하여 공간 내에 있는 열에너지의 총량인 순복사열을 구성하는 현열속, 잠열속, 토양열속(H, LE, G)을 산정하였다. 또한 에너지 평형에 따라 산정된 각 실험동의 열속과 지표면 복사량 관측자료을 정량적으로 비교하여 옥상녹화의 적용성을 평가하였다. 2021년 7월 21일부터 2021년 7월 28일 까지 모니터링한 결과 옥상녹화의 열 효율은 일반 콘크리트 지붕에 비해 실내온도가 최대 6.83℃ 낮게 나타나며 이는 여름철 건물 내부의 온도조절에 필요한 에너지 저감효과를 볼 수 있다. Flux Profile Method를 적용한 결과 옥상녹화의 전체 열속 중 현열속 28.5% 잠열속 70.7%, 토양열속 0.5% 의 복사량 분포를 보였고, 일반 콘크리트 지붕은 현열속 45.3%, 잠열속 38.6%, 토양열속 16.2% 으로 나타났다. 이와 같은 방법은 옥상녹화의 정량적 평가를 가능하게 함으로서 향후 기후변화 대응방안 및 전략 수립 시 옥상녹화의 온도저감효과 분석에 적극 활용할 수 있을 것으로 판단된다.

  • PDF

Application of Flux Profile Method for Evaluating the Temperature Decreasing Effects of Green roof (여름철 옥상녹화의 온도저감효과 평가를 위한 Flux Profile Method의 적용)

  • Kwon, You Jeong;Seo, YongWon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.94-94
    • /
    • 2021
  • 현재 전 지구적으로 일어나고 있는 극단적 기후현상과 이로 인한 자연재해의 원인은 복합적이다. 기후변화로 인한 영향과 동시에 도시화 또한 하나의 원인으로 작용하고 있다. 이러한 영향을 완화하기 위한 방안으로 도시의 그린인프라와 저영향개발은 최근 지속가능한 발전을 위해 꼭 필요한 요소로 자리잡고 있다. 그린인프라 유형 중 하나인 옥상녹화는 많은 이점을 제공한다. 도시에 위치한 건물의 상층부, 내부 및 주변 온도을 낮춤으로써 얻을 수 있는 에너지절감 효과와 강우 시 상당량의 빗물을 저류함으로써 기대되는 우수유출 저감효과, 그리고 도시 공간 내 식물의 적극적인 도입으로 인한 이산화탄소 배출 저감 효과 등을 기대할 수 있다. 본 연구에서는 도시지역의 열섬현상완화와 유출저감의 방안 중 하나인 옥상녹화(Green roof)의 효과를 정량적으로 평가하기 위해 콘크리트로 이루어진 동일한 제원의 실험동을 구축하고, 실험동 내외부의 연직방향 온도, 습도, 강우, 풍속, 일사량 등의 기상자료를 측정할 수 있는 센서를 설치하였다. 각 실험동에서 측정된 기상자료를 Flux Profile Method를 적용하여 무강우기간과 강우발생기간 동안의 연직 방향의 현열속, 잠열속, 토양열속(H, LE, G) 을 산정하였다. 에너지 평형에 따라 산정된 각 실험동의 열속과 지표면 복사량 관측자료을 정량적으로 비교하여 적용성을 평가하였다. 실험의 대조군인 일반 코팅재로 마감된 콘크리트 지붕의 무강우 기간 중 최대 현열속 693.82 W/m2 잠열속은 330.15 W/m2 으로 나타났으며, 실험군인 옥상녹화가 조성된 지붕의 최대 현열속 436.27 W/m2, 잠열속 949.20 W/m2 으로 나타났으며, 산정치와 관측치 시계열의 NSE는 0.81 으로 Flux Profile Method를 통해 산정된 열속의 정확도는 비교적 높은 것으로 나타났다. 이와 같은 방법으로 옥상녹화의 정량적 평가가 가능해짐으로써 향후 기후변화 대응방안 및 전략 수립 시 옥상녹화의 온도저감효과 분석에 적극 활용할 수 있을 것으로 판단된다.

  • PDF

Study on the magnetic flux distribution of transformer by the use of finite element method (유한요소법에 의한 변압기의 자속분포 해석에 관한 연구)

  • 임달호;현동석;이철직
    • 전기의세계
    • /
    • v.29 no.4
    • /
    • pp.247-255
    • /
    • 1980
  • In this study, an application of Finite Element Method which, in principle, based on variational calculus has been presented for the two-dimensional analysis of magnetic flux distribution in the shell type core of single phase transformer. The necessary stationarity condition of energy functional and boundary conditions were determined under the assumptions that the electromagnetic field considered is stationary and that the effect of eddy current is negligible. In the process of application the domain of magnetic field was divided into triangle subsectional elements and then the matrix equations were constructed for the respective triangular element and for those of all after the manipulation of minimization process to the vector potential of magnetic field at the each vertex of the element. Furthermore the numerical computation for the equations was guided by the Gaussian Elimination Methods. As the results obtained, it is found that the aspect of magnetic flux distribution inside the core as well as the leakage flux profile at the vicinity of the inner leg of the core is not much different from the well-known distribution profile of magnetic flux, however, the procedure shows to possess the merit of the uniquely deterministic nature for the flux distribution at the desired points.

  • PDF

Modeling of flux enhancement in presence of concentration polarization by pressure pulsation during laminar cross flow ultrafiltration

  • Kumar, Kamal;De, Sirshendu
    • Membrane and Water Treatment
    • /
    • v.1 no.4
    • /
    • pp.253-271
    • /
    • 2010
  • A theoretical study for the flux enhancement by pulsation of transmembrane pressure is presented for osmotic pressure controlled ultrafiltration under laminar flow regime. The transient velocity profile is solved analytically using Green's function method. Time dependent convective diffusive equation is solved to quantify the membrane surface concentration and the permeate flux, numerically. The effects of the amplitude and frequency of pulsation on flux, surface concentration and observed retention are studied.

A Method for Critical Heat Flux Prediction in Vertical Round Tubes with Axially Non-uniform Heat Flux Profile

  • Shim, Jae-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2008
  • In this study a method to predict CHF(Critical heat flux) in vertical round tubes with axially non-uniform cosine heat flux distribution for water was examined. For this purpose a local condition hypothesis based CHF prediction correlation for uniform heat flux in vertical round tubes for water was developed from 9,366 CHF data points. The local correlation consisted of 4 local condition variables: the system pressure(P), tube diameter(D), mass flux of water(G), and 'true mass quality' of vapor($X_t$). The CHF data points used were collected from 13 different published sources having the following operation ranges: 1.01 ${\leq}$ P (pressure) ${\leq}$ 206.79 bar, 9.92${\leq}$ G (mass flux) ${\leq}$ 18,619.39 $kg/m^2s$, 0.00102 ${\leq}$ D(diameter) ${\leq}$ 0.04468 m, 0.0254${\leq}$ L (length) ${\leq}$ 4.966 m, 0.11 ${\leq}$ qc (CHF) ${\leq}$ 21.41 $MVW/m^2$, and -0.87 ${\leq}X_c$ (exit qualities) ${\leq}$ 1.58. The result of this work showed that a uniform CHF correlation can be easily extended to predict CHF in axially non-uniform heat flux heater. In addition, the location of the CHF in axially non-uniform tube can also be determined. The local uniform correlation predicted CHF in tubes with axially cosine heat flux profile within the root mean square error of 12.42% and average error of 1.06% for 297 CHF data points collected from 5 different published sources.

Simple Analysis Method for the Interrupting Capability of a Contact System in a Molded Case Circuit Breaker

  • Choi, Young-Kil;Jee, Seung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1257-1261
    • /
    • 2017
  • This paper focuses on understanding the interrupting capability of an arc contact system in a molded case circuit breaker (hereafter MCCB). We selected four types of MCCBs and analyzed the magnetic flux density distributions in the contact systems caused by the fault currents. We ascertained that the magnetic flux density profile varies according to the shape of the contact system and was asymmetric at both the ends of an arc, perpendicular to the arc column because of the magnetic grid installed in the contact system. The asymmetric difference creates a magnetic force that pushes the arc current outwards and provides an interrupting capability. We have introduced a simple analysis method for determining the interrupting capability of the contact system for an MCCB by the arc-driving magnetic flux density.

current profiles in a coated conductor with transport current (외부 전류가 흐를 때 초전도 선재에서의 전류 분포)

  • Yoo, Jae-Un;Lee, Sang-Moo;Jung, Ye-Hyun;Lee, Jae-Young;Youm, Do-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.1-4
    • /
    • 2007
  • The current profiles in a coated conductor with transport current were calculated using an iterative inversion method from the data of the magnetic flux density profiles measured. The applied current was increased from 0 to 60 A by 10A step and decreased down to -60A by 20A step. The magnetic flux profiles were measured at a distance of 400 mm above the surface of the coated conductor using a scanning hall probe method. The current profiles calculated were very different from the Bean model: current density profile is not a constant in the critical region. However the aspect of the change of the current and magnetic flux density profiles in the case of decreasing applied current are similar to the theoretical calculations in Brandt's paper.

FORMATION OF LINE PROFILE: SEI METHOD

  • CHOE SEUNG-URN;KANG MIN-YOUNG;KIM KYUNG-MEE
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.2
    • /
    • pp.93-105
    • /
    • 1996
  • We have solved the radiative transfer problem using a Sobolev approximation with an escape probability method in case of the supersonic expansion of a stellar envelope to an ambient medium. The radiation from the expanding envelope turns out to produce a P-Cygni type profile. In order to investigate the morphology of the theoretical P-Cygni type profile, we have treated $V_\infty,\;V_{sto},\;\beta$ (parameters for the velocity field), it and E(parameter for collisional effect) as model parameters. We have investigated that the velocity field and the mass loss rate affect the shapes of the P-Cygni type profiles most effectively. The secondarily important factors are $V_\infty,\;V_{sto}$. The collisional effect tends to make the total flux increased but not so much in magnitude. We have infered some physical parameters of 68 Cyg, HD24912, and $\xi$ persei such as $V_\infty,\;M$ from the model calculation, which shows a good agreenment with the observational results.

  • PDF

Moving Temperature Profile Method for Efficient Three-Dimensional Finite Element Welding Residual Stress Analysis for Large Structures (대형구조물의 효율적 3차원 용접잔류응력해석을 위한 새로운 이동 온도 프로파일 방법)

  • Cheol Ho Kim;Jae Min Gim;Yun Jae Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.2
    • /
    • pp.75-83
    • /
    • 2023
  • For three-dimensional finite element welding residual stress simulation, several methods are available. Two widely used methods are the moving heat source model using heat flux and the temperature boundary condition model using the temperature profile of the welded beads. However, each model has pros and cons in terms of calculation times and difficulties in determining welding parameters. In this paper, a new method using the moving temperature profile model is proposed to perform efficiently 3-D FE welding residual stress analysis for large structures. Comparison with existing experimental residual stress measurement data of two-pass welding pipe and SNL(Sandia National Laboratories) mock-up canister shows the accuracy and efficiency of the proposed method.