Analysis of the Correlation between Human Sensibility and Physical Property of luminous Sources -Focused on Response according to Character of Color Temperature by luminous Sources- (건축조명광원의 광학적 특성에 따른 인간의 감성반응 분석 -조명광원별 색온도 특성에 따른 반응을 중심으로-)

  • Lee, Jin-Sook;Oh, Do-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this research is to acquire emotional data on luminous source by measuring and evaluating human emotional response to the change of the optical feature of luminous environment Luminous sources used in actual architectural space were selected with the optical feature of luminous soured then to measure and analysis human emotional response on Luminous Source. As a result of that 1) In the result of performance measurement by the item of the clear vision of an optic function the fluorescent lamp of daylight indicated the most excellent Performance. 2) In the item of fatigue and stress, the metal halide lamp and mercury lamp showed the most 3) In $\ulcorner$ suitable in light$\lrcorner$, $\ulcorner$a similar with daylight$\lrcorner$ adjective of the amenity item the fluorescent lamp of daylight which color temperature was high turned up to be high also, in $\ulcorner$brilliant$\lrcorner$, adjective, the metal halide lamp and mercury lamp turned up to be low. 4) In the result of factor analysis, three factors $\ulcorner$activity$\lrcorner$, $\ulcorner$potency$\lrcorner$, $\ulcorner$evaluation$\lrcorner$ were abstracted and $\ulcorner$activity$\lrcorner$ factor has the most influential on evaluating the mood of interior space. 5) For the affection in the mood evaluation by each luminous sources, $\ulcorner$activity$\lrcorner$ factor was the most influential by metal halide lamp and fluorescent lamp of daylight, $\ulcorner$potency$\lrcorner$ factor was most influential by kind of incandescent lamp, $\ulcorner$evaluation$\lrcorner$ factor was most influential by fluorescent lamp of low color temperature.

A Experimental Study the Wall Lighting focus on Rate of Illuminance : in case of fluorescent lamp and hallogen lamp (조도 비를 중심으로 한 벽면진열대의 조명실험연구 : 형광램프와 할로겐램프를 중심으로)

  • 김현지;안옥희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.1-7
    • /
    • 2004
  • This experimental study investigates the wall display of shoes shops among the commercial space to suggest a desirable lighting by focusing on the lighting on the lighting surroundings. The important outcomes of this study are summarized below. The result of the experiment for the wall lighting: For the wall lighting, which needs a diversity, there should be various light source or bigger rate of illuminance between the ambient lighting and the local lighting. There is another possibility that is we can use the lower rate of illuminance with the ambient lighting and the local lighting or higher illuminance generally. The other wall lighting, which need a luminance and a emotional response, will be more effective as they take the lower rate of illuminance with the ambient lighting and the local lighting or higher illuminance generally.

Sporulation or Cercospora canescens Ellis & Martin in culture (녹두 갈색무늬병균(Cercospora canescens Ellis & Martin)의 분생포자 형성에 관한 연구)

  • Kwon Shin Han;Oh Jeung Haing
    • Korean journal of applied entomology
    • /
    • v.20 no.1 s.46
    • /
    • pp.21-24
    • /
    • 1981
  • This study was conducted to obtain a supply of conidia sufficient for screening mungbean mutant lines for a source of resistance to Cercospora leaf spot caused by Cercospora canescens Ellis and Martin. Abundant sporulation occurred in cultures on mungbean leaf decoction oatmeal agar(MOA) exposed to about 2,500 Lux of fluorescent light. but it did not occur in continuous darkness. The conditions that produced maximum number of conidia was not coincided with those for vegetative growth and pigmentation in culture medium. Removal of aerial mycelium in culture by brushing with sterile water so enhanced the conidial production that oatmeal agar medium(OA) could be useful for production of abundant conidia by the treatment.

  • PDF

The Study on Envronmental Sanitation for Night High School. -Illuminate- (야간 고등학교의 환경위생학적 조사 -조명을 중심으로-)

  • 김난천;오석흔
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.40-45
    • /
    • 1978
  • We have selected 36 schools of a total of night high schools for boys and girls in seoul and measured intensity of illumination of the classroom, The corridors and the stairs that students study and live, with priority given to an illumination, a primary factor of environmental sanitation of school following is the result. 1. The maximum average intensity of illumination of the classroom is 93.2 Lux, and the minimum average intensity of illumination 39.5 Lux. Mean$\pm$S, is 59.03$\pm$22.8 Lux 2. The maximum average intensity of illumination of the corridor is 39.2 Lux, and the minimum average intensity of illumination 11.1 Lux. 3. The maximum average intensity of illumination of the stair is 11.58 Lux, and the minimum average intensity, of illumination 4.92 Lux, mean$\pm$S.D is 7.88$\pm$10.0Lux. 4. Schools with tile illumination facilities more than 50 Lux are 63.8% and less than 50 Lux are 36.2%. 5. Schools with 9-11 facilities of a source of light per classroom by a fluorescent lamp are the most as 30.50%. 6. As for the corridor, schools with the illumination equipment less than 10 Lux are 27.8%, are more than 10 Lux 72.2% 7. As for the stairs schools with the illumination equipment less than 10 Lux are 77.8%, and more than 10 Lux 10 Lux 22.2%.

  • PDF

Synthesis of N-doped Titania using Ammonium Hydroxide and Photocatalytic Degradation of Humic Acid (암모니아수를 이용한 N-doped TiO2 제조 및 부식산의 광촉매 분해)

  • Cho, A-Young;Nam, Yun-Seon;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.95-102
    • /
    • 2012
  • To advance luminance efficiency of Titania at visible range, N-doped $TiO_2$ was prepared by using ammonium hydroxide as a source of nitrogen. The photoactivities of the synthesized $TiO_2$ were evaluated on the basis of degradation of humic acid in aqueous solutions with different light sources, UV-C, UV-A and fluorescent lamp. As a result, at UV-C is high efficiency $UV_{254}$ decrease and TOC removal. In this study, the best synthetic conditions of N-doped $TiO_2$ were 5.0 M of ammonium hydroxide concentration and calcination temperature of $550^{\circ}C$. The degradation rate of humic acid as an evaluation of photoactivities of the catalysts were conducted with pH variation, decrease rate of molecular absorption, removal rate of total organic carbon and fluorescece evolution for humic acid solution. XRD and SEM were applied for analysis of surface analysis of the catalysts.

  • PDF

Low Cost Omnidirectional 2D Distance Sensor for Indoor Floor Mapping Applications

  • Kim, Joon Ha;Lee, Jun Ho
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.298-305
    • /
    • 2021
  • Modern distance sensing methods employ various measurement principles, including triangulation, time-of-flight, confocal, interferometric and frequency comb. Among them, the triangulation method, with a laser light source and an image sensor, is widely used in low-cost applications. We developed an omnidirectional two-dimensional (2D) distance sensor based on the triangulation principle for indoor floor mapping applications. The sensor has a range of 150-1500 mm with a relative resolution better than 4% over the range and 1% at 1 meter distance. It rotationally scans a compact one-dimensional (1D) distance sensor, composed of a near infrared (NIR) laser diode, a folding mirror, an imaging lens, and an image detector. We designed the sensor layout and configuration to satisfy the required measurement range and resolution, selecting easily available components in a special effort to reduce cost. We built a prototype and tested it with seven representative indoor wall specimens (white wallpaper, gray wallpaper, black wallpaper, furniture wood, black leather, brown leather, and white plastic) in a typical indoor illuminated condition, 200 lux, on a floor under ceiling mounted fluorescent lamps. We confirmed the proposed sensor provided reliable distance reading of all the specimens over the required measurement range (150-1500 mm) with a measurement resolution of 4% overall and 1% at 1 meter, regardless of illumination conditions.

Novel polyvinyl alcohol film dosimeter containing 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide dye for high dose application

  • Khalid A. Rabaeh;Ahmed A. Basfar;Issra' M.E. Hammoudeh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3383-3387
    • /
    • 2023
  • A new dyed polyvinyl alcohol (PVA) film dosimeter based on 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MMT) tetrazolium dye is proposed in this study for measuring high gamma radiation dose. Gamma cell irradiator that contains Co-60 gamma-ray source was used to expose the novel MMT-PVA films to different doses up to 25 kGy. The changed in optical property of irradiated and unirradiated films were characterized by UV-Vis spectrophotometer. The results show that the dose sensitive and the linear range of irradiated films were increased considerably with increase of MMT concentration from 1 to 5 mM. The dose response of dyed PVA film changed substantially with changing relative humidity (12-74%) as well as irradiation temperature (10-40 ℃). The absorbance of the unirradiated films does not change up to 10 days in dark while a significant increase in their absorbance was reported for similar films under fluorescent light. The irradiated dosimeters that kept in dark showed a perfect stability for 54 days. It was found that no obvious impact of dose rate on the irradiated MMT-PVA film dosimeters.

Growth and Phytochemicals of Lettuce as Affected by Light Quality of Discharge Lamps (방전램프의 광질에 따른 상추의 생장 및 파이토케미컬 분석)

  • Lee, Jae Su;Nam, Sang Woon;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.400-407
    • /
    • 2013
  • This study was performed to analyze the effect of light quality of discharge lamp on growth and phytochemicals contents of lettuce (Lactuca sativa L. cv. Jeokchima) grown under metal halide (MH) lamp, high-pressure sodium (HPS) lamp, and xenon (XE) lamp in a plant factory. Cool-white fluorescent (FL) lamp was used as the control. Photoperiod, air temperature, relative humidity, $CO_2$ concentration, and photosynthetic photon flux (PPF) in a plant factory were 16/8 h (day/night), $22/18^{\circ}C$, 70%, 400 ${\mu}mol{\cdot}mol^{-1}$, and 200 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. MH lamp had the greatest fraction of blue light (400-500 nm) of 23.0%. However, HPS lamp had the lowest fraction of 4.7% for blue light and the greatest fraction of 38.0% for red light (600-700 nm). At 11 and 21 days after transplanting, leaf length, leaf width, leaf area, shoot fresh weight, and shoot dry weight of lettuce as affected by the light quality of the discharge lamp were significantly different. The leaf area of lettuce grown under HPS, MH, and XE lamp increased by 45.7%, 16.3%, and 9.5%, respectively, as compared to the control. These results were similar for shoot fresh weight. Growth characteristics of lettuce grown under HPS lamp increased since HPS lamp had more fraction of red light. However, growth of lettuce grown under MH and XE lamp decreased since they had more fraction of blue light. As compared to the control, the ascorbic acid in lettuce leaves grown under discharge lamp decreased. The greatest anthocyanins accumulation of 0.70 mg/100 g was found at MH treatment. Anthocyanins content in lettuce leaves grown under XL and HPS lamp were 79.3% and 8.6%, respectively, compared with the control. Growth and phytochemicals contents of lettuce were highly affected by the different spectral distribution of the discharge lamp. These results indicate that the combination of discharge lamp or LED lamp for enhancing the light quality of discharge lamps is required to increase the growth and phytochemicals accumulation of lettuce in controlled environment such as plant factory.

Growth and Anthocyanins of Lettuce Grown under Red or Blue Light-emitting Diodes with Distinct Peak Wavelength (상이한 피크파장의 적색광 및 청색광 발광다이오드 조사에 따른 상추의 생장 및 안토시아닌)

  • Lee, Jae Su;Kim, Yong Hyeon
    • Horticultural Science & Technology
    • /
    • v.32 no.3
    • /
    • pp.330-339
    • /
    • 2014
  • Growth and anthocyanins of lettuce (Lactuca sativa L., 'Mid-season') grown under LED lamps with blue light in the range of 430-470 nm or with red light in the range of 630-670 nm were analyzed in this study. Cool-white fluorescent light was used a s the control. P hotosynthetic photon flux, p hotoperiod, air temperature, relative humidity, and $CO_2$ concentration in a closed plant production system were $201{\pm}2\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 16/8 hours (day/night), $22/18^{\circ}C$, 70%, and $400{\mu}mol{\cdot}mol^{-1}$, respectively. At 21 days after light quality treatment, growth characteristics and anthocyanins content of lettuce as affected by the peak wavelength of blue or red LED were significantly different. Among peak wavelengths treated in this stusy, R1 treatment (peak wavelength 634 nm) and R6 treatment (peak wavelength 659 nm) were effective for increasing leaf width, leaf area, shoot fresh weight, and photosynthetic rate of lettuce. B5 treatment (peak wavelength 450 nm) and B4 treatment (peak wavelength 446 nm) increased the anthocyanins concentration and chlorophyll content in lettuce leaves, respectively. Anthocyanins in lettuce leaves increased linearly with decreasing hue value of leaf color and with increasing SPAD value of lettuce leaves. From these results, it was concluded that the red LED with peak wavelengths of 634 nm and 659 nm and the blue LED with peak wavelengths of 450 nm can be used as potential light spectra for increasing the yield and anthocyanins accumulation of leafy vegetable.

Optimization of Light Source Combination through the Illuminance and Color Temperature Simulation of Circadian Lighting Apparatus (감성조명용 조명기기의 조도 및 색온도 시뮬레이션을 통한 광원 조합의 최적화)

  • Park, Yang-Jae;Choi, Jong-Hyun;Jang, Myong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.8
    • /
    • pp.248-254
    • /
    • 2009
  • The aim of this study is to optimize the light source combination which can maximize the capability of the illuminance and color temperature of circadian lighting apparatus. To achieve this goal, the circadian lighting apparatus was consisted of two different types of fluorescent lamps having different color temperature of 2000K and 8000K, respectively, and the capability of the illuminance and color temperature of circadian lighting apparatus was evaluated by optical simulation as the number of the respective lamps were varied. Considering the Kruithof's curve and exceptional cases, the ranges of illuminance and color temperature for the living activities were reclassified in 4 groups - gathering, studying, relaxing and sleeping - so that the target range of illuminance and color temperature of lighting apparatus was settled. As a result, in the case of adopting two fixtures in which four 2000K lamps and five 8000K lamps were consisted, respectively to one fixture, the highest illuminance was expected at 4000K and over 500lx of illuminance was calculated between 3000K and 6000K. Through the optimized combination of light sources, the range of illuminance and color temperature were calculated as $44{\sim}750lx$ and $2500{\sim}6500K$, respectively.