• 제목/요약/키워드: Fluorescence detection system

검색결과 133건 처리시간 0.027초

Miniaturized Fluorometer Based on Total Internal Reflector and Condensing Mirror

  • Jang, Dae-Ho;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.81-85
    • /
    • 2013
  • A miniaturized fluorescence detection system based on total internal reflection (TIR) configuration, which is applicable to detecting the presence of biological materials labeled with fluorescence dye in micro total analysis systems (${\mu}TAS$), is proposed. In conventional fluorescence testing and analysis devices, interference between the excitation light beam and the emitted light from dyes is unavoidable. This paper presents a fluorescence detection system based on TIR configuration that allows the excitation light beam and the emitted light to be spatially perpendicular to each other so as to minimize the interference where fluorescence emission is detected at the orthogonal angle to the excitation beam. We achieved the limit of detection of about 5 nmol/L with a high linearity of 0.994 over a wide range of 6-FAM mol concentration, being comparable to that in earlier studies.

형광과 여기광을 공간적으로 분리하는 바이오칩용 소형 형광측정시스템 (Miniature Biochip Fluorescence Detection System with Spatial Separation of Fluorescence from Excitation Light)

  • 김호성;김용권;박주한;이국녕;최재호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.378-383
    • /
    • 2005
  • We report the development of miniature fluorescence detection systems that employ miniature prism, mirrors and low coat CCD camera to detect the fluorescence emitted from 40 fluorescently-labeled protein patterns without scanner. This kind of miniature fluorescence detection system can be used in point of care. We introduce two systems, one uses prism+mirror block and the other uses prism and two mirrors. A large NA microscope eyepiece and low cost CCD camera are used. We fabricated protein chip containing multi-pattern BSA labeled with Cy5, using MEMS technology and modified the surface chemically to clean and to immobilize proteins. The measurements show that the combination of prism and mirrors can homogenize elliptical excitation light over the sample with higher optical efficiency, and increase the separation between excitation and fluorescence light at the CCD to give higher signal intensity and higher signal to noise ratio. The measurements also show that protein concentrations ranging from 10 ng/ml to 1000 ng/ml can be assayed with very small error. We believe that the proposed fluorescence detection system can be refined to build a commercially valuable hand-held or miniature detection device.

집적화된 Lab-On-a Chip을 위한 광센서의 제작 및 특성 평가 (Development of Photo-sensor for Integrated Lab-On-a-Chip)

  • 김주환;신경식;김용국;김태송;김상식;주병권
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.404-409
    • /
    • 2004
  • We fabricated photo-sensor for fluorescence detection in LOC. LOC is high throughput screening system. Our LOC screens biochemical reaction of protein using the immunoassay, and converts biochemical reaction into electrical signal using LIF(Laser Induced Fluorescence) detection method. Protein is labeled with rhodamine intercalating dye and finger PIN photodiode is used as photo-sensor We measured fluorescence emission of rhodamine dye and analyzed tendency of fluorescence detection, according to photo-sensor size, light intensity, and rhodamine concentration. Detection current was almost linearly proportional to two parameters, intensity and concentration, and was inversely proportional to photo-sensor size. Integrated LOC consists of optical-filter deposited photo-sensor and PDMS microchannel detected 50 (pg/${mu}ell$) rhodamine. For integrated LOC including light source, we used green LED as the light source and measured emitted fluorescence.

405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능 (The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode)

  • 정영수;정유진;이종민;최기봉
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

프리즘을 이용한 소형 단백질칩 분석 형광측정 시스템 개발 (Miniature Fluorescence Detection System for Protein Chips by Prism)

  • 최재호;김호성;이국녕;김은미;김용권;김병기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2040-2042
    • /
    • 2004
  • This paper presents a miniature optical system for the fluorescence detection of the patterned protein chip. The patterned protein chip was fabricated using MEMS process. The fluorescence from the patterned protein chip was measured while varying the concentration of the BSA. The fluorescence light is separated spatially from the excitation beam using mini-size prism to increase SNR (Signal-to-Noise Ratio). The combination of prism and mirrors can convert the excitation light from the laser diode to uniform illumination on the specimen. We believe that the proposed system for fluorescence detection can be applied to rea1ization of point-of-care.

  • PDF

In Situ Fluorescence Optical Detection Using a Digital Micromirror Device (DMD) for 3D Cell-based Assays

  • Choi, Jong-Ryul;Kim, Kyujung;Kim, Donghyun
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.42-46
    • /
    • 2012
  • We have developed a fluorescence optical detection system using a digital micromirror device (DMD) for monitoring 3D cell culture matrices in situ. Full 3D imaging with fast scanning speed was implemented by the combined action of a DMD and a motorized stage. Imaging results with fluorescent microbeads measure the minimum axial resolution of the system as $6.3{\mu}m$, while full 1-mm scanning through 3D alginate-based matrix was demonstrated. For cell imaging, improved images were obtained by removing background fluorescence although the scanning distance was reduced because of low intracellular fluorescence efficiency. The system is expected to be useful to study various dynamics and behaviors of 3-dimensionally cultured cells in microfluidic systems.

Microcystin Detection Characteristics of Fluorescence Immunochromatography and High Performance Liquid Chromatography

  • Pyo, Dong-Jin;Park, Geun-Young;Choi, Jong-Chon;Oh, Chang-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권2호
    • /
    • pp.268-272
    • /
    • 2005
  • Different detection characteristics of fluorescence immunochromatography method and high performance liquid chromatography (HPLC) method for the analysis of cyanobacterial toxins were studied. In particular, low and high limits of detection, detection time and reproducibility and detectable microcystin species were compared when fluorescence immunochromatography method and high performance liquid chromatography method were applied for the detection of microcystin (MC), a cyclic peptide toxin of the freshwater cyanobacterium Microcystis aeruginosa. A Fluorescence immunochromatography assay system has the unique advantages of short detection time and low detection limit, and high performance liquid chromatography detection method has the strong advantage of individual quantifications of several species of microcystins.

형광 발현 암세포 탐지를 위한 맞춤형 검출시스템 개발 (Design of a customizable fluorescence detection system for fluorescently labeled tumor cells)

  • 조경래;서정혁;최세운
    • 한국정보통신학회논문지
    • /
    • 제23권3호
    • /
    • pp.261-266
    • /
    • 2019
  • 유동 세포 분석법은 세포나 입자에 대하여 정밀하고 다양한 광학적 특성을 제공해주는 전기적 탐지 기술이다. 형광 처리된 세포나 미립자에 특정한 파장의 빛을 가함으로써 발생 되는 광 산란과 형광 방출을 통해 세포의 크기와 입상도를 포함한 다차원적인 정보를 제공해주는 유동 세포 분석법은 생체 의학 분야 또는 생물 물리학 분야에서 중요한 역할을 수행한다. 그러나 유동 세포 분석법은 고가이며 장비 설치에 있어 적절한 공간이 필요하고 형광 염료 선택에 제한적이라는 단점을 가지고 있다. 따라서 본 논문에서는, 상용화된 유동 세포 분석에 사용되는 고가의 레이저와 운영시스템 대신 발광 다이오드, 마이크로 컨트롤러와 광 검출기를 사용한 저가의 형광세포 측정 시스템을 개발하여 사용자가 원하는 형광 염료에 대한 자유도를 높였다. 또한, 3D 프린터를 사용하여 모듈별 소형화 및 경량화를 통한 사용자 맞춤형 제작이 가능하도록 하였다. 그 결과, 형광처리 한 세포의 양에 변화를 주어 발광도를 측정하였을 때, 높은 선형성이 보임을 확인할 수 있었다.

형광 공초점 주사 현미경의 측정 강도 향상을 위한 반사 광학계의 제안 및 설계 (Proposal and design of reflecting optical system to improve detection intensity in fluorescence confocal scanning microscopy)

  • 강동균;서정우;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.187-190
    • /
    • 2002
  • Confocal microscopy is very popular technology in bio-medical inspection due to its ability to reject background signals and to measure very thin slide of thick specimens, which is called optical sectioning. But intensity of detected signal in fluorescence type confocal microscopy is so small that only 0.2% of emitted fluorescence light can be detected in the best case. In this paper, we proposed the reflecting optical system to improve the detection intensity and designed the optical system by optimal design method. At the end of the paper, we analyzed the characteristics of the proposed reflecting optical system.

  • PDF

LOC 형광검출 소자를 위한 광 다이오드의 제작 및 특성 평가 (Development of Photo-diode for LOC fluorescence detector)

  • 김주환;신경식;김용국;김상식;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.100-103
    • /
    • 2003
  • Signal detection technologies such as fluorescence, charge and electrochemical detection used in the monolithic capillary electrophoresis system to convert the biochemical reaction into the electrical signal. The fluorescence detection using photodiodes that measure fluorescence emitted from eluting molecules is widely used for the monolithic capillary electrophoresis system. In this paper, in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive$(4k{\Omega}{\cdot}cm)$ wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571{\Omega}$ to $393{\Omega}$.

  • PDF