• Title/Summary/Keyword: Fluid velocity

Search Result 2,488, Processing Time 0.033 seconds

Control of the Casting Defects in the Gravity Tilt Pour Casting Process (경동식 중력주조법에 의한 주조결함 제어)

  • Yeom, Ki-Dong;Hong, Chun-Pyo
    • Journal of Korea Foundry Society
    • /
    • v.18 no.3
    • /
    • pp.262-270
    • /
    • 1998
  • Gravity tilt pour casting can effectively guarantee the reduction of various casting defects by controlling the rotation speed and the tilting angle of the mold during tilt pouring. The relationship between casting process parameters and the soundness of castings has been investigated in order to determine the optimum process variables in the gravity tilt pour casting process. In order to evaluate the effect of rotation speed on mold filling patterns, a video camera was employed to visualize the in-situ fluid flow behavior of the molten metal, and the relevant fluid velocity was also estimated. X-ray and mechanical tests were also performed to evaluate the effect of fluid velocity on casting quality. With the rotation speed lower than 0.5 r.p.m., which is nearly corresponding to the critical velocity of stability in the fluid flow, sound castings were obtained without having any casting defects. It can be concluded that the gravity tilt pour casting process is an effective process for manufacturing sound casting products with enhanced physical and mechanical properties.

  • PDF

The Correction of Fluid Temperature for Hot-wire Anemometer (열선 유속계에 대한 유체 온도의 보정)

  • 심상학
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.92-97
    • /
    • 1999
  • This paper reports by simple method that is quickly corrected the effects of fluid temperature for the hot wire anemometer. We are concerned with a variable output of hot wire anemometer on arbitrary fluid temperature. Hot wire by measuring boundary layer of turbulent flow has been calibrated by arbitrary temperature lower than 10$0^{\circ}C$, and velocity lower than 20m/s. As a result, we could pick up the temperature factor affected by output of hot wire anemometer from related in output of arbitrary temperature to output of room temperature. By using temperature factor on the output of hot wire anemometer, we also obtained that the relationship of velocity was of no effect by temperature of fluids. About results of calibrated hot wire, uncertainly of velocity is 2.15% at room temperature and 3.1% at arbitrary temperature.

  • PDF

CFD flow analysis of 150mm shower heads depending on plasma pitch (플라즈마 피치에 따른 150mm 샤워헤드에 대한 CFD 유동해석)

  • Kim, Dong-Hwa;Kim, Ho-Bum;Cho, Chong-Du;Jeong, Dea-Kyo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.585-589
    • /
    • 2008
  • This study is performed to analyze the fluid flow about 150mm shower heads of semiconductor device. Under the air pressure, the ideal gas of moving fluid is injected as 5m/s velocity into inlet of shower heads and the flow distribution in shower heads is measured according to pitch of plasma distribution device. As results, the maximum and minimum value of fluid velocity are investigated with their position. The velocity values at outlet are also studied. From two experiment using the plasma distribution device, the results of CFD are compared with the experimental results. That results shows stable flow of fluid in that case of corrected design from CFD.

  • PDF

Finite Element Vibration Analysis of Curved Beam Conveying Fluid of Uniform Velocity (일정속도를 갖는 유체를 포함하는 곡관의 유한요소 진동해석)

  • 서영수;정의봉;오준석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.285-290
    • /
    • 2003
  • A method for the dynamic analysis of curved beam conveying fluid presents. The dynamics of curved beam is based on inextensible theory and the fluid in curved beam has uniform velocity. The equations of motion of curved beam are decoupled by in-plane motion and out-of$.$Plane motion. The solutions of equations are presented by a finite element method and validate by comparing the natural frequency with analytical solution, straight beam theories and Nastran. The influence of fluid velocity on the frequency response function is illustrated and discussed.

  • PDF

A Study of Micro Induction-type EHD Pump with Temperature Gradient (온도차를 이용한 유도형 마이크로 EHD 펌프에 관한 연구)

  • Youn, Yong-Kyu;Kim, Yung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1069-1071
    • /
    • 1993
  • This paper presents the characteristics of micro induction EHD(Electro Hydro Dynamic) pump in which the fluid has a temperature gradient to the transverse direction of a traveling wave. The effects of the channel depth, the wave length and wave form of the treveling wave has been investigated in micro pump. The effect of temperature gradient also has been investigated. The fluid velocity becomes large as the wave length becomes small and the temperature gradient becomes high. The channel depth has little influence on the fluid velocity. The EHD pump driven by the square wave has the larger fluid velocity than that driven by the sinusoidal wave.

  • PDF

EXACT SOLUTION FOR STEADY PAINT FILM FLOW OF A PSEUDO PLASTIC FLUID DOWN A VERTICAL WALL BY GRAVITY

  • Alam, M.K.;Rahim, M.T.;Islam, S.;Siddiqui, A.M.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.16 no.3
    • /
    • pp.181-192
    • /
    • 2012
  • Here in this paper, the steady paint film flow on a vertical wall of a non-Newtonian pseudo plastic fluid for drainage problem has been investigated. The exact solution of the nonlinear problem is obtained for the velocity profile. Also the average velocity, volume flux, shear stress on the wall, force to hold the wall in position and normal stress difference have been derived. We retrieve Newtonian case, when material constant ${\mu}_1$ and relaxation time ${\lambda}_1$ equal zero. The results for co-rotational Maxwell fluid is also obtained by taking material constant ${\mu}_1$ = 0. The effect of the zero shear viscosity ${\eta}_0$, the material constant ${\mu}_1$, the relaxation time ${\lambda}_1$ and gravitational force on the velocity profile for drainage problem are discussed and plotted.

DUFOUR AND HEAT SOURCE EFFECTS ON RADIATIVE MHD SLIP FLOW OF A VISCOUS FLUID IN A PARALLEL POROUS PLATE CHANNEL IN PRESENCE OF CHEMICAL REACTION

  • VENKATESWARLU, M.;BABU, R. VASU;SHAW, S.K. MOHIDDIN
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.21 no.4
    • /
    • pp.245-275
    • /
    • 2017
  • The present investigation deals, Dufour and heat source effects on radiative MHD slip flow of a viscous fluid in a parallel porous plate channel in presence of chemical reaction. The non-linear coupled partial differential equations are solved by using two term perturbation technique subject to physically appropriate boundary conditions. The numerical values of the fluid velocity, temperature and concentration are displayed graphically whereas those of shear stress, rate of heat transfer and rate of mass transfer at the plate are presented in tabular form for various values of pertinent flow parameters. By increasing the slip parameter at the cold wall the velocity increases whereas the effect is totally reversed in the case of shear stress at the cold wall. It is observed that the effect of Dufour and heat source parameters decreases the velocity and temperature profiles.

Stability Analysis of Multi-wall Carbon Nanotubes Conveying Fluid (유체유동에 의한 다중벽 탄소나노튜브의 안정성 해석)

  • Song, Oh-Seop;Yun, Kyung-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.6
    • /
    • pp.593-603
    • /
    • 2010
  • In this paper, vibration and flow-induced flutter instability analysis of cantilever multi-wall carbon nanotubes conveying fluid and modelled as a thin-walled beam is investigated. Non-classical effects of transverse shear and rotary inertia and van der Waals forces between two walls are incorporated in this study. The governing equations and the associated boundary conditions are derived through Hamilton's principle. Numerical analysis is performed by using extend Galerkin method which enables us to obtain more exact solutions compared with conventional Galerkin method. Cantilevered carbon nanotubes are damped with decaying amplitude for flow velocity below a certain critical value, however, beyond this critical flow velocity, flutter instability may occur. Variations of critical flow velocity with both radius ratio and length of carbon nanotubes are investigated and pertinent conclusion is outlined.

Vibration Stability Analysis of Multi wall Carbon Nanotubes Considering Conveying Fluid Effect (유체유동효과를 고려한 다중벽 탄소나노튜브의 진동 및 안정성 해석)

  • Yun, Kyung-Jae;Choi, Jong-Woon;Song, Oh-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.219-224
    • /
    • 2012
  • In this paper, vibration and flow-induced flutter instability analysis of cantilever multiwall carbon nanotubes conveying fluid and modelled as a thin-walled beam is investigated. Non-classical effects of transverse shear and rotary inertia are incorporated in this study. The governing equations and the associated boundary conditions are derived through Hamilton's principle. Numerical analysis is performed by using extend Galerkin method which enables us to obtain more exact solutions compared with conventional Galerkin method. Cantilevered carbon nanotubes are damped with decaying amplitude for flow velocity below a certain critical value, however, beyond this critical flow velocity, flutter instability may occur. Variations of critical flow velocity with both radius ratio and length of carbon nanotubes are investigated and pertinent conclusion is outlined.

  • PDF

Numerical modeling of thrombolysis - Effects of nozzle types and ejection velocities

  • Jeong, Woo-Won;Rhee, Kye-Han
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.13-18
    • /
    • 2006
  • Direct injection of a fibrinolytic agent to the intra-arterial thrombosis may increase the effectiveness of thrombolysis by enhancing the permeation of thrombolytic agents into the blood clot. Permeation of fibrinolytic agents into a clot is influenced by the surface pressure, which is determined by the injection velocity of fibrinolytic agents. Computational fluid dynamic methods were used in order to predict clot lysis for different jet velocities and nozzle arrangements. Firstly, thrombolysis of a clot was mathematically modeled based on the pressure and lysis front velocity relationship. Direct injection of a thrombolytic agent increased the speed of thrombolysis significantly and the effectiveness was increased as the ejecting velocity increased. The nine nozzles model showed about 20% increase of the lysed volume, and the one and seventeen nozzles models did not show significant differences. Secondly, thrombolysis was modeled based on the enzyme transport and the fluid flow equations, and quasi steady numerical analysis was performed. Clot lysis efficiency was also increased as injection velocity increased.

  • PDF