• Title/Summary/Keyword: Fluid pressure

Search Result 4,314, Processing Time 0.031 seconds

Numerical Modeling of Regenerative Rotary Heat Exchanger: A Review

  • Baruah, Netramoni;Prasanna, Kumar G.V.
    • Journal of Biosystems Engineering
    • /
    • v.42 no.1
    • /
    • pp.44-55
    • /
    • 2017
  • Background: Heat recovery is one of the prominent ways to save a considerable amount of conventional fossil fuel and minimize its adverse effects on the environment. The rotary heat exchanger is one of the most effective and efficient devices for heat recovery or heat exchanging purposes. It is a regenerative type of heat exchanger, which has been studied and used for many heat recovery purposes. However, regenerative thermal wheels have been mostly used as heat recovery systems in buildings. For modeling a rotary regenerator, it is very important to numerically consider all the factors involved, such as effectiveness, rotational speed, geometrical size and shape, and pressure drop (${\Delta}p$). In recent times, several researchers have actively studied the rotary heat exchangers, both theoretically and experimentally. Reviews: In this paper different advances in the numerical modeling of regenerative rotary heat exchangers in relation to fluid flow and heat transfer have been discussed. Researchers have indicated that the effectiveness of the regenerative rotary heat exchanger depends on various factors including, among many others, rotational speed, rotational period and combustion power. It is reported that with the increase of periodic rotation the deviation of theoretical results from the experimental result increases. The available literature indicates that regenerative heat exchangers are having relatively more effectiveness (60-80%), compared to other heat exchangers. It is also observed that the finite difference method and finite volume methods are mostly used for discretizing the heat transfer governing equations, under some assumptions. Research also indicates that for the effectiveness calculation the ${\varepsilon}-NTU$ method is the most popular and convenient.

The antihyperlipidemic effect of alginate-free residue from sea tangle in hyperlipidemic rats

  • Yim, Mi-Jin;Lee, Jeong Min;Choi, Grace;Cho, Soon-Yeong;Lee, Dae-Sung
    • Fisheries and Aquatic Sciences
    • /
    • v.22 no.11
    • /
    • pp.27.1-27.6
    • /
    • 2019
  • Background: In order to assess the high value-added use of the alginate-free residue of sea tangle, an animal study was performed to evaluate the functional activities and key compounds present. In the animal study, sea tangle and the alginate-free residue demonstrated good anti-hyperlipidemic and anti-arteriosclerotic abilities. Results: The functional compounds in the alginate-free residue of the sea tangle were effectively extracted by supercritical fluid extraction (SFE). The optimum extraction temperature and pressure were 40 ℃ and 6500 psi (M1) in the SFE, a better method in comparison to the conditions of 70 ℃ and 4500 psi (M2), respectively. The anti-atherosclerotic effects of the alginate-free residue of sea tangle (M1, M2) were investigated in Sprague-Dawley rats treated with poloxamer 407, Triton WR 1339, corn oil, and a high-fat diet. The M1 fraction reduced the serum lipid levels with greater efficacy than the M2 fraction. In the hyperlipidemic rats, treatment with M1 decreased the serum triglyceride (TG), total cholesterol (TC), and low-density lipoprotein-cholesterol (LDL-C) levels when compared to the levels in normal rats. Conclusion: Our results demonstrated that the alginate-free residue of sea tangle reduces serum TC, TG, and LDL-C. These results suggest that the alginate-free residue of sea tangle contains physiologically active components, such as fucosterol, that may exert beneficial effects in the prevention of atherosclerosis.

Liposuction in the Treatment of Lipedema: A Longitudinal Study

  • Dadras, Mehran;Mallinger, Peter Joachim;Corterier, Cord Christian;Theodosiadi, Sotiria;Ghods, Mojtaba
    • Archives of Plastic Surgery
    • /
    • v.44 no.4
    • /
    • pp.324-331
    • /
    • 2017
  • Background Lipedema is a condition consisting of painful bilateral increases in subcutaneous fat and interstitial fluid in the limbs with secondary lymphedema and fibrosis during later stages. Combined decongestive therapy (CDT) is the standard of care in most countries. Since the introduction of tumescent technique, liposuction has been used as a surgical treatment option. The aim of this study was to determine the outcome of liposuction used as treatment for lipedema. Methods Twenty-five patients who received 72 liposuction procedures for the treatment of lipedema completed a standardized questionnaire. Lipedema-associated complaints and the need for CDT were assessed for the preoperative period and during 2 separate postoperative follow-ups using a visual analog scale and a composite CDT score. The mean follow-up times for the first postoperative follow-up and the second postoperative follow-up were 16 months and 37 months, respectively. Results Patients showed significant reductions in spontaneous pain, sensitivity to pressure, feeling of tension, bruising, cosmetic impairment, and general impairment to quality of life from the preoperative period to the first postoperative follow-up, and these results remained consistent until the second postoperative follow-up. A comparison of the preoperative period to the last postoperative follow-up, after 4 patients without full preoperative CDT were excluded from the analysis, indicated that the need for CDT was reduced significantly. An analysis of the different stages of the disease also indicated that better and more sustainable results could be achieved if patients were treated in earlier stages. Conclusions Liposuction is effective in the treatment of lipedema and leads to an improvement in quality of life and a decrease in the need for conservative therapy.

A Study on the Flow Path Position Design of Waviness Friction Pad for Drag Torque Reduction in Wet Type DCT (파형 습식클러치의 드래그 토크 저감을 위한 파형내 유로 위치 설정 설계 연구)

  • Cho, Junghee;Han, Juneyeol;Kim, Woojung;Jang, Siyoul
    • Tribology and Lubricants
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Drag torque reduction in a wet clutch pack is a key aspect of the design process of the dual clutch transmission (DCT) system. In order to reduce the drag torque caused by lubricant shear resistance, recently developed wet clutch pack systems of DCT, as well as automatic transmission and other four-wheel drive (4WD) couplings, frequently utilize wavy wet clutch pads. Therefore, wavy shape of friction pad are made on the groove patterns like waffle pattern for the reduction of drag torque. Additionally, the groove patterns are designed with larger channels at several locations on the friction pad to facilitate faster outflow of lubricant. However, channel performance is a function of the waviness of the friction pad at the location of the particular channel. This is because the discharge sectional area varies according to the waviness amplitude at the location of the particular channel. The higher location of the additional channel on the friction pad results in a larger cross-sectional area, which allows for a larger flow discharge rate. This results in reduction of the drag torque caused by the shear resistance of DCTF, because of marginal volume fraction of fluid (VOF) in the space between the friction pad and separator. This study computes the VOF in the space between the friction pad and separator, the hydrodynamic pressure developed, and the shear resistance of friction torque, by using CFD software (FLUENT). In addition, the study investigates the dependence of these parameters on the location and waviness amplitude of the channel pattern on the friction pad. The paper presents design guidelines on the proper location of high waviness amplitude on wavy friction pads.

Development of ELISA for Brucella abortus RB51 II. Purification of 8kDa antigen and development of ELISA using its antigen of Brucella abortus RB51 (부루세라 RB51의 ELISA 진단법 개발 II. Brucella abortus RB51균의 8kDa 항원 정제 및 ELISA 진단법 개발)

  • Her, Moon;Cho, Dong-hee;Jung, Byeong-yeal;Cho, Seong-kun;Jung, Suk-chan;Kim, Ok-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.51-57
    • /
    • 2001
  • A procedure for extraction and purification of 8 kDa antigen of Brucella abortus RB51 was developed. Bacteria heat inactivated at $60^{\circ}C$, 30 min was extracted by 1% sarcosine and followed by fluid pressure liquid gel filtration chromatography of 2 series, Superose 12 HR 10/30 and Sephacryl S-100. There was produced $71.46{\mu}g/g$(wet) of 8 kDa antigen, and it resisted 1% trypsin, solved 1% triton X-100 higher than distilled water and inactivated 0.1% proteinase K. These results show that 8 kDa antigen may be a lipoprotein existed cell surface of B. abortus RB51. Also, we developed ELISA using purified 8 kDa surface antigen of Brucella abortus RB51 strain, its specificity and sensitivity was 95.0%, 98.6%, respectively. As compared with dot-blot assay using whole cell and ELISA using 8 kDa antigen, its correlation was 93.5%.

  • PDF

Numerical Investigation of Factors affecting Photoresist Stripping Process on the ITO Surface using the Spray Method (노즐 분사 방식의 ITO 표면 포토레지스트 박리과정 요인의 수치해석)

  • Kim, Joon Hyun;Lee, Joon Hyuck;Kang, Tae Seong;Joo, Gi-Tae;Kim, Young Sung;Jeong, Byung Hyun;Lee, Dae Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.158-165
    • /
    • 2017
  • This study investigated spraying factors applicable to stripper usage. Cyclodextrine, as environment-friendly material, was included in the stripper composition. An efficient spray technology was applied for the Photoresist strip. For industrial applications, stripping requires a temperature below $50^{\circ}C$, a strip time within 50 s, and chemically stable activation. Spraying factors were organized considering many conditions-orifice diameter, working pressure (inlet speed), spray distance, and spray angle. For commercial practicability, the flow rate was limited to 3 L/min. The nozzle parameters were nozzle orifice diameter of 1.8-2.2 mm, spray distance of 40-60 mm, and injection speed of 0.7-1.2 m/s. Through the thermal spray movement of the fluid, the thermal boundary layer for a chemical reaction just above the ITO-glass surface and momentum region for sufficient agitation (above 4 m/s) was achieved.

A Study on Alternative Fan Selection and Verification in Military Electronic Equipment (방산용 전자장비의 팬 선정 및 검증에 관한 연구)

  • Jin, Sung Eun;Kim, Hwan Gu;Yoon, Eui Youl;Jeon, Hee Ho;Kim, Seung Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1091-1097
    • /
    • 2017
  • Sales of commercial-type cooling fans intended for application in military electronics are often discontinued during equipment production. This results in requirements for alternative fan selection as well as equipment performance and reliability tests, such as high-temperature operation testing. This study deals with alternative fan selection and verification methods that can be used during the production process. First, an alternative fan was selected by calculating the flow and pressure required to effectively cool the equipment, then the feasibility of the selected fan was verified using a reliable CFD heat dissipation analysis model. Following this, a high-temperature operation test was performed using the alternative fan in the equipment. Results demonstrated that the equipment satisfied its required function in a high-temperature environment, and the main parts as well as internal air temperature were found to be thermally stable.

A Research of Prehospital 119 Emergency Medical Service for Stroke Patients (병원 전 뇌졸중 환자의 구급의료 실태 분석)

  • Song, Hyun-Mok;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.14-20
    • /
    • 2012
  • This study analyzes the influencing factors of prehospital 119 Emergency Medical Service for Stroke Patients in prehospital. From July, 2010 to June, 2011, 123 patients were diagnosed with Stroke in Emergency Medical Center. Among 123 patients, the prehospital assessment rates were as follows : blood pressure checked 73.2 %, pulse checked 73.2 %, respiratory checked 64.2 %, $SpO_2$ checked 79.7 %, pupil reflex test 88.6 %, Electrocardiogram checked 14.6 %, blood sugar checked 19.5 %. Prehospital emergency medical care, Oropharyngeal airway insertion 2.4 %, Manual airway maneuvers 17.1 %, endotracheal intubation 2.7 %, oxygen supply 35.4 %, and suction and intravenous fluid therapy 0 %. The property of mental status evaluation by 119 Emergency Medical Service was nearly perfect, but the patients assessment and emergency medical care were not.

A Study on the Removal Method of Radioactive Corrosion Product using its Magnetic Property (방사성 부식생성물의 자기적 성질을 이용한 제거방법에 대한 연구)

  • 송민철;공태영;이건재
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.73-79
    • /
    • 2003
  • In a pressurized water reactor, radioactive corrosion products (CRUD) in primary coolant system are one of the major sources for the occupational radiation exposure of the personnel in a nuclear power plant. Through the recent trend of long term fuel cycle in a nuclear power Plant, radioactive corrosion products deposited in reactor core for a long time are also the cause of Axial Offset Anomaly (AOA) having m effect on reactor power by the hideout of boron. CRUD consist primarily of magnetite, nickel ferrite, cobalt ferrite, and so on. They have the characteristic of strong magnetism. Therefore it is performed the conceptual design to develop the filter which removes the CRUD by magnetic field that is generated by an arrangement of permanent and electric magnets. Contrary to the conventional filter, the proposed filter does not interrupt the fluid flow, so there is little pressure drop and it can be used continuously. It is expected to be applied as one of the technologies for removal of the CRUB.

  • PDF

A Study on Cutting Performance of the BTA Drilling (BTA드릴가공의 절삭성능에 관한 연구)

  • 장성규;김순경;전언찬
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.65-72
    • /
    • 1998
  • The BTA drilling chip is better for deep hole drilling than other self-piloting with pad drilling chips because the large length to diameter ratio allows a unique cutting force dispersion and better supplies the high pressure fluid. Therefore the BTA is useful for many tasks, such as coolant hole drilling of large scale dies, as well as tube seat drilling, which is essential for the heat exchanger, and variable component drilling for automobiles. Deep hole drilling has several significant problems, such as hole deviation, hole over-size, circularity, straightness, and surface roughness. The reasons for these problems, which often result in quality short comings, are an alignment of the BTA drilling system and the unbalance of cutting force by work piece and tool shape. This paper analyzes the properties through an experiment which com¬pared single-edge BTA drills with multiple-edge BTA drills, as well as the shapes of the tools to cause an unbalance of cutting force, and its effect on the precision of the worked hole. Conclusions are as follows. 1) In SMSSC drilling, 60m/min of BTA with single and multi-edged tools proved the best cutting condition and the lowest wear character. 2) The roundness got a little worse as cutting speed was increased, but surface roughness was hot affected. 3) It was proved that the burnishing torque of both drills approached 26%. which is almost the same as the 24% insisted on by Griffiths, and the dispersion characteristic of the multi-edged BTA drill proved better than the single-edge BTA drill.

  • PDF