• 제목/요약/키워드: Flowmeter test

검색결과 72건 처리시간 0.025초

국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구 (A Study on the Evaluation of Measurement Uncertainty for the National Calibration and Test Organizations (Liquid Flow))

  • 임기원
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.1012-1019
    • /
    • 2000
  • A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.

  • PDF

습식 다회선 초음파유량계의 특성평가 연구 (A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter)

  • 이동근;조용;고재명;박태진;박종호
    • 한국유체기계학회 논문집
    • /
    • 제16권4호
    • /
    • pp.5-9
    • /
    • 2013
  • An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.

전달 시간차 방식 다회선 초음파 가스 유량계 개발 (Study on the Development of Multi-Path Ultrasonic Gas Flowmeter)

  • 황원호;박상국;이치환;장경영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF

스크류 유량계의 개발 및 정밀 성능평가에 관한 연구 (A Study on the Development and Precise Performance Test of a Screw Type Flowmeter)

  • 황종대;오지영;정윤교;이상렬
    • 한국정밀공학회지
    • /
    • 제26권5호
    • /
    • pp.87-95
    • /
    • 2009
  • This research introduces the efficient modeling and manufacturing method using reverse engineering combined with rotational simulation of a pair of screw and mill-turn machining realized a proposed NC program. Because previously developed model had insufficient flow measuring accuracy, we considered that matter in the aspect of method of modeling and performance test. For that reason we modified the modeling which could minimize a gab between male and female screw, and developed precise tester which consists of constant tank, flowmeter and load cell, etc., and then conducted the test for defining characteristic and accuracy of flowmeter and repeated same test 5-times. Consequently we could obtain satisfied measuring accuracy and reproducibility indicated in the catalog of master model. Hence we give our conclusion as to the validity of developing accurate screw type flowmeter using the proposed process such as reverse engineering, mill-turn machining and precise performance test.

치수생활력 검사를 위한 Laser Doppler Flowmeter의 이용 (THE USE OF LASER DOPPLER FLOWMETER FOR PULP VITALITY TEST)

  • 서완종;김현정;남순현;김영진
    • 대한소아치과학회지
    • /
    • 제25권3호
    • /
    • pp.562-568
    • /
    • 1998
  • 저자는 본 병원에 내원한 환자중 미완성치근단을 가지고 있으며 외상받은 치아 및 자가이식치아를 대상으로 기존의 치수생활력 검사방법과 더불어 LDF를 이용한 검사방법을 통해 다음과 같이 요약할 수 있다. 1. 치수생활력유무를 판단함에 있어 현재까지 널리 사용된 전기치수검사, 냉검사등의 방법은 치수 내 신경발달 정도 및 피검자의 주관에 의해 반응이 다르게 나타나는 경우가 많다. 2. 이에 반해 LDF를 이용한 치수생활력 검사방법은 위음성 및 위양성 반응의 빈도가 낮아 신뢰도가 높으며 비교적 조기에 치수생활력을 측정할 수 있는 우수한 방법이다.

  • PDF

Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장 (Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique)

  • 임기원;최종오
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.

경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교 (Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제32권9호
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.

밸브 하류에 설치된 건식 초음파유량계의 편차특성 (Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves)

  • 이동근;조용
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.12-18
    • /
    • 2012
  • This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results.

엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석 (Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test)

  • 양인영
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

A study on the dynamics of a turbine-meter-type flowmeter for hydraulic systems

  • Yokota, Shinichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.60-65
    • /
    • 1994
  • In this study, the dynamic characteristics of a turbine-meter-type flowmeter is investigated by making use of the remote instantaneous flow rate measurement method (RIFM). The results of the frequency response test indicated that the gain of the flow rate of the turbine-meter-type flowmeter relative to the flow rate of the RIFM was nearly unity up to 40Hz and the phase lag of the flow rate became 90 degrees at 70Hz.

  • PDF