• Title/Summary/Keyword: Flow-rate Coefficient

Search Result 933, Processing Time 0.028 seconds

The Optical Properties of Plasma Polymerized Organic Thin Films Using Spectrophotometry (분광광도계법을 이용한 플라즈마 중합 유기박막의 광학특성)

  • Choi, C.S.;Park, B.K.;Park, C.B.;Lee, D.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.28-32
    • /
    • 1993
  • A deposition rate of styrene thin films is linearly increased, but one of benzene thin films is nonlinearly increased with increasing discharge power under maintaining a polymerization time, pressure and monomer flow rate. And, the reduction of transmittance at shortwave is larger than that of transmittance at longwave. The refractive index with wavelength is various from 1.55 to 1.65. The refractive index of their thin films is decreased with increasing discharge power. Also, it is known that measured results are valid because the calculation of the extinction coefficient is about $10^3$ within variation of refractive index.

  • PDF

A Study of Reflood Heat Transfer in Electrically-Heated Fuel Rod Bundle (電氣加熱式 模擬燃料棒 다발에서의 再冠水 熱傳達 硏究)

  • 정문기;박종석;이영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.7-14
    • /
    • 1986
  • To predict the fuel clad temperature during the reflooding phase of a LOCA, one may need a knowledge of reflood heat tranfer mechanism in a rod bundle. For this purpose reflooding experiments have been carried out with an electrically heated 3*3 rod bundle. Using the method for the determination of local heat transfer coefficient from the measured wall temperature the parametric effects of coolant flow rate, initial wall temperature, coolant subcooling and heat generation rate on the propagation of rewetting front were investigated. Prediction of the wall temperature histories for these experiments was discussed using REFLUX code with modification of the rewetting temperature correlation. Through this modification, better agreement between experiment and prediction was obtained.

Performance Evaluation of Scale Mitigation Unit for Heat Exchangers (열교환기에 대한 스케일 완화장치의 성능평가)

  • Mo, Jeong-Ha;Sin, Sang-Cheol;Kim, Gyeong-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1149-1156
    • /
    • 2001
  • The objective of the present study is to investigate the performance of electronic scale mitigation unit(ESMU), which reduces the amount of scale in a heat exchanger. The circular tube with diameter of 19mm and plate-and-frame heat exchangers with 20 thermal plates were used for the tests. In order to accelerate the rate of scale in a laboratory test, artificial hard water of 1000ppm(as CaCO$_3$) was recirculated at a flow rate of 5 lpm, 7 lpm, and 9 lpm throughout the tests. The effect of ESMU on the scale thickness and overall heat transfer coefficients was examined. The test results showed that the ESMU could reduce the scale deposits even in the acceleated test.

Performance Evaluation of Electronic Scale Mitigation Unit for Plate Heat Exchanger (판형 열교환기에 대한 전자식 스케일 완화 장치의 성능평가)

  • Seo, Hae-Sung;Shin, Sang-Chul;Kim, Kyong-Woo;Moh, Jeong-Hah;Kim, Dong-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.13-18
    • /
    • 2000
  • The objective of the Present study is to investigate the performance of electronic scale mitigation unit(ESMU), which reduces the amount of scale in a heat exchanger. A plate heat exchanger with 20 thermal plates is used for the tests. In order to accelerate the rate of fouling in a laboratory test artificial hard water of 2000 ppm(as $CaCO_3$) is recirculated at a flow rate 5L/min throughout the tests. The overall heat trans(or coefficients and fouling factors are examined. Results show that the ESMU technology can significantly reduce the scale deposits.

  • PDF

Usefulness Assessment of Noninvasive Bladder Pressure Measurement for BPH Diagnosis (전립선 비대증 진단에서의 비침습적 방광내압계측 유용성 평가)

  • Jeong, Do-Un;Chung, Wan-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.865-866
    • /
    • 2006
  • The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfort methods. There for in this study hardware device and computer software have been developed that enables the analysis of the urine flow rate and vesical pressure signal measured during voiding. These signals were recorded simultaneously and transmitted to the PC. For the measurement system evaluation, the model system for the lower urinary system of men was designed. From the evaluation of the model system, vesical pressure was correlated with the occlusion degree. In a pilot study on 5 male subjects, means of standard deviation was 1.06, average error rate was 2.09 and coefficient variation was 2.09.

  • PDF

Absorption of Water Vapor into an Absorbing Binary Liquid Film Falling over a Horizontal Tube Bank (수평원관군상(水平圓管群上)의 이원흡수용액유동(二元吸收溶液流動)에 의(依)한 전달흡수특성(傳達吸收特性))

  • Kim, S.;Kim, Y.I.;Seo, S.C.;Hwang, D.K.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.583-589
    • /
    • 1988
  • Condensation of water vapor into an absorbent liquid of LiBr-water solution falling over a bank of water cooled horizontal tubes was investigated theoretically. The governing conservation equation for a re-defined physical transport phenomena were solved numerically using a finite difference method. Raw parameters were used in this study, since reliable experimental data is required prior to a dimensionless parametric study. The average values of wall heat transfer coefficient and interfacial absorption rate were defined to see the system performance. Other parameters include tube diameter, streamwise coordinate (and number of tubes in row), mass flow rate, and the wall temperature. The effects of these quantities on the absorption processes and suggestions for a rational system design have been presented.

  • PDF

A study on the heat transfer performance of evaporator for absorption chiller (흡수식 냉온수기용 증발기의 전열성능에 관한 연구)

  • Kwon, Oh-Kyung;Cha, Dong-An;Yun, Jae-Ho;Kim, Hyo-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.192-197
    • /
    • 2008
  • The objectives of this paper are to measure the heat transfer and pressure drop of the heat transfer tube for an evaporator of absorption system applications. Five types of heat transfer tubes with different shape and heat transfer area are tested in the present experiment. Heat transfer and pressure drop performance of heat transfer tubes are measured in various operating conditions, and compared each other. The results show that the heat transfer rate of thermoexcel notch tube and low fin tube increases about 27.6% and 11.6% at the refrigerant flow rate 250 kg/h compared with that of bare tube, respectively. The thermoexcel notch tube is shown the best performance considering pressure drop and heat transfer coefficient.

  • PDF

The Optical Properties of Multi-layer Organic Thin Films (플라즈마 다층 유기박막의 광학특성)

  • Choi, C.S.;Lee, S.H.;Park, B.K.;Hwang, M.W.;Jin, K.S.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1189-1192
    • /
    • 1993
  • Organic thin films were fabricated an using interelectrode capacitively coupled type plasma polymerizaion apparatus, and their optical properties were investigated. A deposition rate of styrene thin films is linearly increased, but one or vinyl-pyridine thin films is nonlinearly increased with increasing of polymerization time, pressure and monomer flow rate. The transmittance of single layer thin films is constant, but that of multi-layer appeared irregular peak with increasing of the number of layers. And then the refractive index of organic thin films is various from 1.55 to 1.65 with wavelength, the extinction coefficient indicated $10^{-3}$.

  • PDF

Thermal Design Analysis of an Absorption Heat Transformer for using Waste Hot Water (폐온수 이용 제 2 종 흡수식 열펌프의 열역학적 설계해석)

  • Kang, Byung-Ha;Kim, Young-In;Lee, Chun-Sik
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.4
    • /
    • pp.285-292
    • /
    • 1985
  • A computer program for thermal design analysis has been developed to predict the performance of an absorption heat transformer. The effects of temperature boost, cooling water temperature and effectiveness of components on the performance were investigated. Not only the detailed thermodynamic states such as temperatures, concentration of the solution, and mass flow rate at each point of the process but also the heat transfer rate in each component could be easily determined with given input parameters. The system's coefficient of performance (COP) was seen to increase with increased effectiveness of components, decreased temperature boost of hot water, and decreased cooling water temperature. Even though the COP increases with increased effectiveness of the components, the variation in the COP is not substantial above certain values of the effectiveness. A reference design point can be selected on this basis.

  • PDF

Respiratory Air Flow Transducer Applicable to Cardiopulmonary Resuscitation Procedure (인공심폐소생술에 활용 가능한 호흡기류센서)

  • Kim, Kyung-Ah;Lee, In-Kwang;Lee, You-Mi;Yu, Hee;Kim, Young-Il;Han, Sang-Hyun;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.833-839
    • /
    • 2013
  • Cardiopulmonary resuscitation (CPR) is performed by thoracic compression and artificial ventilation for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are facing the whole area perpendicular to the flow axis. The present study developed a new air flow transducer conveniently applicable to CPR. Specially designed "sensing rod" samples the air velocity at 3 different locations of the flow cross-section, then transforms into average dynamic pressure by the Bernoulli's law. The symmetric structure of the sensing holes of the sensing rod enables bi-directional measurement simply by taking the difference in pressure by a commercial differential pressure transducer. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.