DOI QR코드

DOI QR Code

A Study of Reflood Heat Transfer in Electrically-Heated Fuel Rod Bundle

電氣加熱式 模擬燃料棒 다발에서의 再冠水 熱傳達 硏究

  • 정문기 (한국원자력연구소 열수력설계실) ;
  • 박종석 (한국에너지연구소 원자력안전센터) ;
  • 이영환 (한국에너지연구소 원자력안전센터)
  • Published : 1986.01.01

Abstract

To predict the fuel clad temperature during the reflooding phase of a LOCA, one may need a knowledge of reflood heat tranfer mechanism in a rod bundle. For this purpose reflooding experiments have been carried out with an electrically heated 3*3 rod bundle. Using the method for the determination of local heat transfer coefficient from the measured wall temperature the parametric effects of coolant flow rate, initial wall temperature, coolant subcooling and heat generation rate on the propagation of rewetting front were investigated. Prediction of the wall temperature histories for these experiments was discussed using REFLUX code with modification of the rewetting temperature correlation. Through this modification, better agreement between experiment and prediction was obtained.

본 연구에서는 가압경수형 원자로심을 모의하는 3*3배열로 된 모의연료 봉다발의 실험장치를 이용하여 재완수과정의 유동특성과 열전달특성을 파악하였으며, 재완수과정중 연료봉의 온도거동을 예측하는 REFLUX코드를 최근 개발된 연구자료를 토대로 수정하여 본실험결과와 비교하였다.

Keywords