• Title/Summary/Keyword: Flow-meter

Search Result 595, Processing Time 0.027 seconds

Diagnosis on performance of turbine flowmeter using differential pressure in the meter (차압을 이용한 터빈유량계 성능 진단)

  • Ha, Young-cheol;Her, Jae-young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.153-159
    • /
    • 2004
  • We have investigated the feasibility of using differential pressure(pressure drop) of gas turbine meter to diagnose turbine performance degradation caused by mechanical wearing damage and/or dirt buildup or erosion. If the differential pressure between the upstream piping and the throat of a turine meter can be correlated to meter flow rate over the operating range of the meter, then a relatively simple differential pressure measurement in the filed might be used to detect meter performance changes. To test this method, we have conducted two experimental simulation on Straightener Integrated Type(SIT) turbine meter. One is fur dirt buildup on turbine blade, the other is for eccentricity of the blade. Results show that this method provide a reliable measure of performance degradation and is useful maintenance indicator.

  • PDF

The Numerical Analysis about the Hunting Factors of the Orifice Meter (오리피스 유량계의 헌팅 원인과 영향인자에 관한 해석적 연구)

  • Shin, Chang-Hoon;Ahn, Seung-Hee;Chung, Jong-Tae;Her, Jae-Young;Kim, Woo-Sik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.150-157
    • /
    • 2005
  • Generally, the flow hunting is observed in almost all of the orifice meters but the intensity of the flow hunting is different at each metering system. So, we were getting some Questions as follows; why such a difference occurs and whether it influence to metering error rate or not. To investigate the flow hunting characteristics, we are trying to examine the flow characteristics around the orifice meter when the transient flow or pressure is generated at after the PCV(Pressure Control Valve) by 3D CFD method. And we have compared numerical results with experimental results at M - PCV station in order to clarify the relations with both the metering-pipeline diameter and flow rate. Finally, we can show some major factors influencing to the flow hunting and propose some correcting scheme of the flow hunting equation.

  • PDF

Fluidic oscillation characteristics of plastic flow meter with the variation of cross-sectional shape of splitters (스플리터 단면형상변화에 따른 플라스틱 유량계의 유동진동특성)

  • Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.15 no.2
    • /
    • pp.56-62
    • /
    • 2021
  • In this study, design technology of a non-mechanical flow meter using fluidic oscillation generated during the fluid flow in the chamber was investigated. To with respect to design a splitter, which is the most important factor in fluid oscillation, a transient flow simulation analysis was performed for three types of shapes and changes in inlet flow velocity. The oscillation characteristics with respect to the time in each case were compared, and it was confirmed that the SM03 model was the best among the presented models. In addition, the FFT analysis of the fluid oscillation results for the SM03 model was used to obtain a linear correlation between the flow velocity change and the maximum frequency, and a frequency of 20.957 (Hz/m/s) per unit flow velocity was obtained. Finally, injection molding simulation and molding experiment of the chamber with the designed splitter were performed.

An Identification Method of the Influence of Flow Conditions on the Flow Metering Error (유량측정 오차에 미치는 유동조건의 영 향 검출방법 연구)

  • Lee, K.B.;Choi, H.M.;Paik, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.34-41
    • /
    • 1991
  • The effect of flow conditions on flow measurement is difficult to identify from the inherent characteristics of the flowmeters and flow standard system. A new experimental approach has been attempted to detect the turbine meter error due to inlet flow conditions. In this try not only the design of the turbine meter package but also the data analysis method was altered. It was found that k factor slope of the turbine meter responds to the change of flow conditions in the test line with higher sensitivity than the degree of the data scattering. The flow standard system of $0.1m^3/s$ was chosen for the investigation. The systematic and random error of the system were less than ${\pm}0.08%$ and ${\pm}0.13%$ respectively.

  • PDF

Real-time measurement of void fraction and its propagation speed of slug flow with two Conductance meters (두 개의 컨덕턴스미터를 이용한 슬러그류의 기공률 및 기공률 전달속력 실시간 측정)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kang, Deok-Hong;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1569-1573
    • /
    • 2004
  • Two ring-type conductance meters were manufactured to measure void fraction and its propagation speed in slug flow. The signal of conductance meter with two rings depends on liquid temperature. Therefore a conductance meter with separated probe designed by Coney (1973), which is independent of liquid temperature, was used and experimentally proved. The manufactured conductance meters showed a good repeatability and agreement with the analytical solution by Coney (1973). From time lag between two conductance meter, we could calculate the propagation speed of void fraction.

  • PDF

Study on the reverse engineering and performance test in the development of screw flowmeter (스크류유량계 개발에 있어서의 역공학 및 성능평가에 관한 연구)

  • Kim Jong-Yoon;Hwang Jong-Dae;Lee Sang-Ryul;Jung Yoon-Gyo
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.132-137
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw type flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flow meter.

  • PDF

The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters (Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계)

  • Kim, Min-Chul;Kwon, Kee-Buem;Yim, Dong-Hyun;Song, Chang-Seuk;Jung, Yong-Seuk;Jang, Tae-Won;Yeu, Ho-Dae;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1000-1011
    • /
    • 1998
  • Background: For the diagnosis or evaluation of airway obstruction in bronchial asthma and chronic obstructive lung disorders, various parameters derived from the forced expiratory volume curve and maximal expiratory flow volume curve have been used. Recently the peak expiratory flow(PEF) measured by the peak flow meter is widely used because of its simplicity and convenience. But there were still no data of the predicted normal values measured by the peak flow meter in Korea. This study was to obtain the predicted normal value of PEF and to know the accuracy of this value to predict $FEV_1$. Method: The measurements of PEF by the MiniWright peak flow meter and several parameters derived from the forced expiratory volume and maximal expiratory flow volume curves by the Microspiro HI 501(Chest Co.) were done in 129 men and 125 women without previous history of the respiratory diseases. The predicted normal values of parameters according to the age and the height were obtained, and the regression equation of $FEV_1$ by PEF was calculated. Results: The predicted normal values of PEF(L/min) were -2.45$\times$Age(year) +1.36 $\times$ Height(cm)+427 in men, and -0.96 $\times$ Age (year) + 2.01 $\times$ Height (cm) + 129 in women. FEFmax derived from the maximal expiratory flow volume curve was less than by 125 L/min in men and 118 L/min in women respectively compared to PEF. $FEV_1$(ml) predicted by PEF was 5.98 $\times$ PEF(L/min) + 303 in men, and 4.61 $\times$ PEF(L/min) + 291 in women respectively. Conclusion : The predicted normal value of PEF measured by the peak flow meter was calculated and it could be used as a standard value of PEF while taking care of patients with airway obstruction. $FEV_1$, the gold standard of ventilatory function, could be predicted by PEF to a certain extent.

  • PDF

A Study on Effects of Temperature Difference between the Inside and Outside the Meter-Run on Natural Gas Flow Measurement Errors (천연가스 계량배관 내$\cdot$외의 온도차가 계량오차에 미치는 영향에 관한 연구)

  • Ha Youngcheol;Lee Chulgu;Chang Seungyong;Lee Kangjin
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.83-89
    • /
    • 1998
  • Experiments had been conducted Qualitatively regarding flow measurement errors of orifice flowmeter due to temperature difference between the inside and outside the natural gas meter-run in case of no pipe insulations. The primary factors considered in this study are fluid velocity and surrounding temperature. In addition, a portion of thermal radiation due to the sun was involved as a factor. The results showed that the considerable errors were not detected even in conditions of low flow rates and large temperature difference between the inside and outside the meter-run.

  • PDF

A Study on the Meter-Out and Meter-In Speed Control Characteristics in Pneumatic Cushion Cylinders (공기압 쿠션 실린더의 미터아웃/미터인 속도제어 특성에 관한 연구)

  • Kim, Do-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Pneumatic cylinders are widely used to actuators in automatic equipments because they are relatively inexpensive, simple to install and maintain, offer robust design and operation, are available in a wide range of standard sizes and design alternatives. This paper presents a comparative study among the dynamic characteristics of meter-out and meter-in speed control of pneumatic cushion cylinders with a relief valve type cushion mechanism. Because of the nonlinear differential equations and a requirement for simultaneous iterative solution in a mathematical model of a double acting pneumatic cushion cylinder, a computer simulation is carried out to investigate pressure, temperature, mass flow rate in cushion chamber and displacement and velocity time histories of piston under various operating conditions. It is found that the piston velocity and pressure response in meter-in speed control are more oscillatory than with meter-out those when pneumatic cushion cylinders are driven at a high-speed. In meter-out speed control, the effective area of the flow control valve is larger than that of meter-in, and the supply pressure has to be much higher than the pressure required to move the load because it has also to overcome the back pressure in cushion chamber.