• Title/Summary/Keyword: Flow resistance test

Search Result 363, Processing Time 0.025 seconds

Synthesis and Characterization of Vinylbenzyl Chloride-co-Styrene-co-Hydroxyethyl Acrylate (VBC-co-St-co-HEA) Anion-Exchange Membrane for All-Vanadium Redox Flow Battery (전바나듐계 레독스-흐름 전지용 Vinylbenzyl Chloride-co-Styrene-co-Hydroxyethyl Acrylate (VBC-co-St-co-HEA) 음이온교환막의 합성 및 특성)

  • Baek, Young-Min;Kwak, Noh-Seok;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.35 no.6
    • /
    • pp.586-592
    • /
    • 2011
  • In this study, we synthesized vinylbenzyl chloride-co-styrene-co hydroxyethyl acrylate (VBC-co-St-co-HEA) copolymer that can be applied to redox the flow battery process. The anion exchange membrane was prepared by the amination and crosslinking of VBC-co-St-co-HEA copolymer. The chemical structure and thermal properties of VBC-co-St-co-HEA copolymer and aminated VBC-co-St-co-HEA(AVSH) membrane were characterized by FTIR, $^1H$ NMR, TGA, and GPC analysis. The membrane properties such as ion exchange capacity(IEC), electrical resistance, ion conductivity and efficiency of all-vanadium redox flow battery were measured. The IEC value, electrical resistance, and ion conductivity were 1.17 meq/g, $1.9{\Omega}{\cdot}cm^2$, 0.009 S/cm, respectively. The charge-discharge efficiency, voltage efficiency and energy efficiency from all-vanadium redox flow battery test were 99.5, 72.6 and 72.1%, respectively.

Fire Resistance Performance of Precast Segmental Concrete Lining for Shield Tunnel (쉴드 터널용 프리캐스트 세그먼트 콘크리트 라이닝의 내화성능)

  • Han, Byung-Chan;Harada, kazunori;Kwon, Young-Jin;Kim, Yun Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.95-105
    • /
    • 2014
  • Reinforced concrete (RC) shield tunnel lining must be designed for fireproof performance because the lining is sometimes exposed to very high temperature due to traffic accidents. Both experimental and numerical studies are carried out to evaluate fire resistance performance of precast RC tunnel lining systems. In the experimental studies, six full-scale precast RC tunnel segments are exposed to fire in order to examine the influence of various parameters on the fire resistance performance of precast RC tunnel lining. We used the temperature curve of the RABT criteria, which are severe conditions of fire temperatures. The fire test showed that the explosive spalling was not observed by substituting concrete to PP fiber reinforced concrete. A transient heat flow analysis was carried out in consideration of the material properties that change with temperature, and the results showed good agreement with the test results.

Effect of Milled Glass Fibers on Corrosion Resistance of PSC Grout Mortar (초단유리섬유가 PSC 그라우트의 부식저항성능에 미치는 영향)

  • Moon, Do-Young;Kim, Sang-Woon;Kim, Dong-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.37-45
    • /
    • 2015
  • In this experimental study, effect of milled glass fibers was investigated on corrosion resistance of PSC grout mortar. In order to check whether the mortar mixture with milled glass fibers satisfy the required properties as a PSC grout, time of flow, bleeding and compressive strength measured. The corrosion resistance were investigated through chloride ion migration test, mortar absorption test and surface resistivity measurement. It is confirmed that all proportions with milled glass fibers have better corrosion resistance than that with only OPC binder. Time of flow was reduced but the bleeding was increased to unacceptable level by using milled glass fibers. Consequently, the mix proportion with milled glass fibers for a PSC grout should be modified to have lower water/binder ratio.

Centrifugal Blower with High Inlet Resistance (고 흡입저항을 가진 원심 송풍기)

  • Kim, Jae-Won
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.2 s.19
    • /
    • pp.15-22
    • /
    • 2003
  • Comprehensive study on a centrifugal blower for air-purifier involving a few physical filters for percolation process has been accomplished for an optimal design of the air handling system. The filtering media causes a flow resistance for induced flows by a rotating impeller. The present methodology is to adopt PIV system for velocity measurements and wind tunnel connected with an anechoic chamber for total performance test of the blower. Trial prototypes for the blades of a rotor and casing are presented for satisfaction of both flow rate and noise level set by design objectives. Tapered blades with a special casing for a fan show good performance data. The results of velocity fields also explain the reason of improvements of the blower performance.

Verification of Prediction Technique of Wave-making Resistance Performance for a Ship attached with a Vertical Blade (수직날개를 부착한 선박의 조파저항 성능 추정 기법의 검증)

  • Choi, Hee-Jong;Park, Dong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • In this paper the developed prediction technique of wave-making resistance performance for a ship attached with a vertical blade had been verified. Numerical analysis program as a prediction technique had been developed using the Rankine source panel method and the vortex lattice method(VLM). The nonlinearity of the free surface conditions was fully taken into account using the iterative method and the trim and the sinkage of the ship were also considered in the numerical analysis program. Panel cutting method was applied to get hull surface panels. Numerical computations were carried out for a 4000TEU container carrier and the vertical blade was attached 6 different locations astern. To investigate the validity of the numerical analysis program the commercial viscous flow field analysis program FLUENT was used to obtain the viscous flow field around the ship and the model test was performed. The model test results were compared with the numerical analysis results.

A Study on Grooving Corrosion at the Weld of a Low Carbon Steel Pipe Made by Electrical Resistance Welding (탄소강관의 ERW 용접부 홈부식 손상에 관한 연구)

  • Kim Yong;Lee Bo-Young
    • Journal of Welding and Joining
    • /
    • v.22 no.5
    • /
    • pp.58-64
    • /
    • 2004
  • Although leakage at a low carbon steel pipe made by electrical resistance welding (ERW) was reported due to grooving corrosion, the cause for the corrosion has not yet been cleared. In order to clarify the main cause, failure analysis on the leaked pipe was carried out, followed by metallographic investigation and corrosion test for the various ERW pipe made with different welding heat input. The microstructure, particularly inclusion content, of the weldment is dependant on the welding heat input applied. For an improper low heat input, the amount of inclusion at the weld was high. High inclusion content accelerated grooving corrosion at the weld. It is therefore that welding heat input should be controlled based on the carbon content of the pipe in order to improve the corrosion resistance of the ERW pipe.

The Relationship between Microstructure and Freezing Thawing Resistance of Polymer-Cement Mortars (폴리머-시멘트 모르타르의 미세구조 동결융합 저항성의 관계)

  • ;;田英治(Eiji Kamada)
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.9
    • /
    • pp.949-956
    • /
    • 1994
  • In order to investigate the relationship between pore size distribution and freezing-thawing resistance of mortars, polymer-cement mortars were prepared by using styrene-butadiene rubber latex, ethylene-vinyl acetate emulsion and polyacrylic ester emulsion with various polymer-cement ratios at constant flow. From the results of the test, polymer-cement mortars had a good pore size distribution for freezing-thawing resistance compared with unmodified mortars because of having a small pore volume in the pore radius range of 103~104 $\AA$ affecting on the frost damage. And the freezing-thawing resistance of polymer-cement mortars was improved with increasing polymer-cement ratio.

  • PDF

Fundamental Study on the Strength and Durability of Ultra-high Strength Concrete (초고강도 콘크리트의 강도 및 내구특성에 대한 기초적 연구)

  • Kang Seong Mook;Choi Jae Jin;Yoo Jung Hoon;Choi Doo Sun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.395-398
    • /
    • 2005
  • In recent years, the applications of high-strength concrete have increased, and high-strength concrete has now been used in many parts of the world. The growth has been possible as a. result of recent developments in material technology and a demand for higher-strength concrete in Korea. In this study, we have an object to produce the ultra-high strength concrete(Super-Con) of over 100MPa with low price materials. First, the binders for Super-Con should be selected by the tests; setting time of paste, flow value and strength of mortar. From the test results, the binders are blended with ordinary portland cement, pulverized portland cement and silica fume. Fundamentally the compressive strength, frost resistance and chloride resistance are investigated.

  • PDF

Characteristics of Rainfall Protection for Stacks (굴뚝의 우수유입방지 특성)

  • Kim, Jong-Chul;Kim, Tae-Hyeung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.18-31
    • /
    • 2000
  • A stack must be designed to 1) reduce or eliminate rainfall or snowfall into a industrial exhaust system, 2) minimize a resistance to flow, 3) maximize the vertical dispersion of the contaminated air and 4) minimize maintenance. The weather cone stacks and the elbow-type stacks are very popular in Korea. But they add some resistance to the exhaust system resulting in reduction of air flow rate, but also deflect the noxious contaminants downward in undiluted form. To solve these problems, ACGIH (American Conference of Governmental Industrial Hygienists) suggested the vertical discharge stack with concentric space between the upper stack with larger diameter and the lower stack with smaller diameter. The preliminary test showed that the vertical discharge stacks did not have the good rainfall protection. The reversed cone were newly devised to satisfy the requirements for the good stack. Subsequently, the amount of rain being penetrated through the stacks was measured while the stacks were simultaneously and naturally exposed to rain in the same area outside. Test results indicate that none of the stacks tested completely exclude rain. The efficiency of rainfall protection and the pressure loss coefficient were compared. The temporary conclusion was reached to the point that the reversed cone stack is the best one. Further research is underway.

  • PDF

Deformation Behavior of Corrosion-Resistant Fe-Cr Alloy

  • Era, Hidenori;Kono, Yusuke;Sasabuchi, Ryota;Miyoshi, Noriko;Tokunaga, Tatsuya;Shinozaki, Nobuya;Lee, Je-Hyun;Shimozaki, Toshitada
    • Applied Microscopy
    • /
    • v.46 no.1
    • /
    • pp.45-50
    • /
    • 2016
  • Iron containing a high amount of chromium is known to be inferior to ductility due to ${\sigma}$ phase formation so that it is generally difficult to apply the plastic deformation process although the alloy possesses a superior characteristics of an excellent corrosion resistance. In this study, Fe-50mass%Cr alloy was melted using high purity powder and the deformation behavior has been investigated by cold rolling and tensile test. The tensile test yielded that the alloy revealed a serration at an early stage of tensile deformation and then the serrated flow vanished to change to a normal work hardening flow at the later stage. The former was governed by twin formation process, the latter by dislocation multiplication one, bringing about a high ductility of 20% or over. The reduction ratio in cold rolling was attained as high as 90%, thus the high corrosion-resistant alloy is able to possess a high ductility.