• Title/Summary/Keyword: Flow measurement method

Search Result 1,040, Processing Time 0.027 seconds

A Study of the Measurement of the Flow Coefficient Cv of a Ball Valve for Instrumentation (계장용 볼 밸브 유량계수 Cv 측정에 관한 연구)

  • Kang, Chang-Won;Yi, Chung-Seob;Jang, Se-Min;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.103-108
    • /
    • 2019
  • The results of the measurement of the flow-rate coefficient (Cv-value) and the analysis of a small ball valve are summarized follows. The Cv-values of 1/2-, 3/4- and 1-inch ball valves were measured using a flow-rate measurement test. The manufacturer obtained the Cv-value using a theoretical calculation method. The new experimental measurement and analysis method yielded more reliable results. In addition, the Cv value obtained through numerical analysis was almost identical the value provided by the manufacturer, which was based on experimental results. A Study on Flow Analysis results are all similar appearances as the reliability of the results.

Development of Stereoscopic PTV Technique and Performance Tests (Stereoscopic PTV 기법의 개발과 성능비교 연구)

  • Lee Sang-Joon;Yoon Jong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.215-221
    • /
    • 2006
  • A stereoscopic particle tracking velocimetry (SPTV) technique based on the 2-frame hybrid particle tracking velocimetry (PTV) method was developed. The expansion of 2D PTV to SPTV is facilitated by the fact that the PTV method tracks individual particle centroids. To evaluate the performance and measurement accuracy of the present SPTV technique, it was applied to flow images of rigid body translation and synthetic standard images of jet shear flow and impinging jet flow. The data processing routine and measurement uncertainty of the SPTV technique are compared with those of conventional stereoscopic particle image velecimet.y (SPBV). In addition, the centroid translation effect of 2D particle image velocimetry (PIV) is defined and its effect on SPIV measurements is discussed. Compared to the SPIV method, the SPTV technique has inherited merits of concise and precise velocity evaluation procedures and provides better spatial resolution and measurement accuracy.

An Experimental Study on Flow Structure inside a Display Cooler Using PIV Techniques (PIV기법을 이용한 전시용 냉장기의 내부 유동장 측정)

  • Park, Cheol-Woo;Baek, In-Je
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.48-55
    • /
    • 2007
  • Flow structure inside a refrigerating compartment of a scale-down display cooler model was investigated experimentally by using PIV (particle image velocimetry) method, a reliable velocity field measurement technique, in the present study. In addition, we also carried out flow visualization regarding flow structure and particle movement inside a display cooler by using a tracer method. As a result, the mean velocity field measurement shows a large scale vortical flow structure inside a refrigerating compartment due to strong entrainment flow, going through a base plate open gaps.

Time Constant of a Fine-Wire Thermocouple Immersed to Fluids (유체에 잠겨있는 가는 열전대의 시간상수 측정)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.190-199
    • /
    • 1998
  • a new measuring method is suggested to determine the time constant of a thermocouple wire to be applied for the measurement of the true fluid temperatures in varying flow states. Based on the techniques of internal heating which are commonly used to measure mean time constants we extend the existing method to measure instantaneous time constants continuously. A method of measurement and analysis is presented and verified experimentally.

  • PDF

Inverse Problem of Determining Unknown Inlet Temperature Profile in Two Phase Laminar Flow in a Parallel Plate Duct by Using Regularization Method (조정법을 이용한 덕트 내의 이상 층류 유동에 대한 입구 온도분포 역해석)

  • Hong, Yun-Ky;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1124-1132
    • /
    • 2004
  • The inverse problem of determining unknown inlet temperature in thermally developing, hydrodynamically developed two phase laminar flow in a parallel plate duct is considered. The inlet temperature profile is determined by measuring temperature in the flow field. No prior information is needed for the functional form of the inlet temperature profile. The inverse convection problem is solved by minimizing the objective function with regularization method. The conjugate gradient method as iterative method and the Tikhonov regularization method are employed. The effects of the functional form of inlet temperature, the number of measurement points and the measurement errors are investigated. The accuracy and efficiency of these two methods are compared and discussed.

Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines (가스터빈엔진 고공성능시험설비의 측정불확도 개선)

  • Lee, Dae-Sung;Yang, In-Young;Jun, Yong-Min;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.

Evaluation of Critical Flow Factor in Natural Gas Flow Measurement Using Sonic Nozzle and International Comparison Results (소닉노즐을 이용한 천연가스 유량측정에서 임계유동인자 계산 및 국제비교 결과)

  • Ha, Youngcheol;Her, Jaeyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.911-917
    • /
    • 1999
  • The sonic nozzle is widely used as reference device for calibrating flowmeters In gas flow measurement and its use requires the Critical Flow Factor(CFF) based on the thermodynamic properties of the gas at the nozzle throat. ISO-9300 provides the calculating method of the factor. But since the CFF from this method show an error over ${\pm}0.5%$ In specific conditions and of ${\pm}0.1{\sim}{\pm}0.2%$ in common Natural Gas(NG) custody transfer condition. this method cannot be applied for gas flow measurement with sonic nozzle. Each research bodies or organizations of the world have joined in order to calculate the CFF more accurately. They have performed these works using their own method and compared the results with each other under the management of ISO. KOGAS have joined those works, because the high-pressure natural gas flow calibration facility of KOGAS will be constructed in late 1999, and then had necessities to calculate a CFF accurately. The calculation method of KOGAS was using the equation of state from AGA-8('94), high accuracy model of ideal gas properties and the solutions of thermodynamic equations. The evaluation results have had a very good consistency within ${\pm}0.05%$ in most NO custody transfer conditions compared to the speed of sound for methane and also shown that the CFF was within ${\pm}0.1%$ compared to the results of other works of the world.

Method for Rapid and Accurate Measurement of Chitosan Viscosity

  • No, Hong -Kyoon;Samuel P. Meyers
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.2
    • /
    • pp.85-87
    • /
    • 1999
  • A simple and rapid method to estimate the viscosity of chitosan using laboratory pipettes was developed. The voscosities of nine different chitosan samples, prepared ini 1 % acetic acid at a 1% concentration , were measured with a standard viscometer. Prior to measurement of flow time of 1% chitosan solution with a pipette, twelve pipettes were assorted into three groups with flow times of 4, 5 and 6 sec after measuring passage of 9 ml of 1% acetic acid througth a 10 ml pipette. With each group of pipettes. flow time of 1% chitosan solution was determined by measuring the delivery time of 5 ml of the 10ml solution through a 10 ml pipette. Results of regression analyses revealed high linear relationship(R2=0.9812, 0.9663, and 0.9754) between viscosities calculated with a viscometer and flow times measured with 4, 5 or 6 sec group pipettes. The viscosity of chitosan could be readily and accurately estimated from these linear regression equation by measuring flow times based on pipette delivery.

  • PDF

A Study on the Measurement Uncertainty of Pipe Prover (파이프 프루버의 측정불확도에 관한 연구)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.10
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

An approach for the functional extension of the remote measurement method of unsteady flow rate

  • Yokota, Shin-ichi;Kim, Do-Tae;Suzuki, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.235-239
    • /
    • 1992
  • The paper describes an approach for estimating unsteady flow rate through oil hydraulic pipelines and components in real time. Recently we have proposed following three unsteady flow rate measurement approaches; RIFM, QIFM and TPFM, in which hydraulic pipeline dynamics are made use of. In this paper, we firstly propose new approaches, i.e, an interpolation and an extrapolation methods in combination with RIFM and TPFM. In the interpolation method, unsteady flow rate at the arbitrary internal location along the pipeline between two points for measuring the two point pressure can be estimated. In this paper, the accuracy and dynamic response of interpolation method are mainly experimentally investigated in detail.

  • PDF