• 제목/요약/키워드: Flow disturbance factor

검색결과 25건 처리시간 0.027초

밸브 하류에 설치된 건식 초음파유량계의 편차특성 (Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves)

  • 이동근;조용
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.12-18
    • /
    • 2012
  • This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results.

주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책 (Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header)

  • 김연환;배용채;이영신
    • 한국소음진동공학회논문집
    • /
    • 제15권8호
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.

유동교란인자(축소·확대관, Tee관)상하류에 설치된 다회선초음파 유량계의 특성 (Characteristics of Multipath Ultrasonic Flowmeter Installed Upstream and Downstream of Flow Disturbance Factors-Contraction, Expansion, and Tee Pipe)

  • 이동근;조용
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.877-883
    • /
    • 2012
  • 정확한 유량측정의 목적으로 다회선방식을 이용한 초음파유량계의 설치가 점차 증가하는 추세에 있으나 이에 대한 설치기준이 아직까지는 수립되어 있지 않아 현장설치 시 많은 혼선을 일으키고 있다. 따라서 측정의 정확도 확보에 영향을 주는 유동교란인자 중에서 확대관, 축소관 및 Tee관이 다회선 초음파유량계의 상하류에 설치되어 있는 경우에 필요로 하는 직관거리를 결정하기 위한 실험을 실시하였다. 실험대상으로는 정확도가 ${\pm}0.5%$ 이하인 제품으로 국산 5회선 2개, 외산 2회선 1개, 4회선 1개 등 4개의 제품을 선정하고 유량 즉, 유속과 직관거리별로 반복적인 실험을 통해 허용오차를 만족하는 설치기준을 제시하였다.

다공성매질을 삽입한 수평채널의 열전달 및 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of a Horizontal Channel Filled with Porous Media)

  • 손영석;신지영;조영일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.244-251
    • /
    • 2009
  • Porous media have especially large surface area per volume, which contain complex fluid passage. If porous media can be applied to cool a CPU or an electronic device with large heat dissipation, it could result in heat transfer enhancement due to the enlargement of the heat transfer area and the flow disturbance. This study is aimed to identify the heat transfer and pressure drop characteristics of high-porosity metal foams in a horizontal channel. Experiment is performed with the various heat flux, velocity and pore density conditions. Permeabilities, which is deduced from Non-Darcy flow model, become lower with increasing pore density. Nusselt number also decreases with higher pore density. High pore density with same porosity case shows higher pressure loss due to the increase of surface area per unit volume. The fiction factor decreases rapidly with increase of Reynolds number in Darcy flow region. However, it converges to a constant value of the Ergun coefficient in Non-Darcy flow region.

A Study on the Fundamental Cause of Stall Stagnation Phenomena in Surges in Compressor Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권2호
    • /
    • pp.119-137
    • /
    • 2017
  • Although the stall stagnation phenomena have often been experienced in site and also analytically in numerical experiments in surges in systems of compressors and flow paths, the fundamental causes have not been identified yet. In order to clarify the situations, behaviours of infinitesimal disturbance waves superposed on a main flow were studied in a simplified one-dimensional flow model. A ratio of the amplifying rate of the system instability to the characteristic slope of the compressor element was surveyed as the instability enhancement factor. Numerical calculations have shown the following tendency of the factor. In the situation where both the sectional area ratio and the length ratio of the delivery flow-path to the suction duct are sufficiently large, the enhancement factors are greater in magnitude, which means occurrence of ordinary deep surges. However, in the situation where the area ratio and/or the length ratio is relatively smaller, the enhancement factor tends to lessen significantly, which situation tends to suppress deep surges for the same value of the characteristic slope. It could result in the stall stagnation condition. In the domain of area ratio vs. length ratio of the delivery duct to the suction duct, contour-lines of the enhancement factor behave qualitatively similar to those of the stall stagnation boundaries of a fan analytically obtained, suggesting that a certain range of the enhancement factor values could specify the stagnation occurrence. The significant decreases in the factors are observed to accompany appearances of phase lags and travelling waves in the wave motions, which macroscopically suggests breaking down of the complete surge actions of filling and emptying of the air in the delivery duct. The strength of the action is deeply related with acoustic interferences and is evaluated in terms of the volume-modified reduced resonance frequency proposed by the author. These observations have shown the fundamental cause and the sequence of the stall stagnation in principle.

전압형 Dual PWM 컨버터의 변조각 지연에 따른 보상법 및 순시전류 제어기 구성 (The Compensation Method of the Modulation-delay for the Voltage type Dual PWM Converter and Composition of the Instantaneous Current Controller)

  • 정연택;김원철;이사영;전지용;김현봉;이근홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.369-372
    • /
    • 1994
  • In this paper, a voltage type dual PWM converter which achives the bidirectional power flow between a AC supply and a DC bus voltage is described. In PWM modulator, there exist a time difference between the sampling time and carrier wave, it achieves stable modulation even the disturbance in the synchronous AC source voltage. And this paper proposes the compensation method and the control method related a disturbance of synchronous signal using the low pass filter and phase shifter for the stable modulation. As a result the voltage type dual PWM converter makes the imput current wave as sinusoid, and performs the high power factor driving.

  • PDF

인공신경망을 이용한 사출성형품의 무게 안정성 제어에 대한 연구 (A Study on the Stability Control of Injection-molded Product Weight using Artificial Neural Network)

  • 이준한;김종선
    • 한국산업융합학회 논문집
    • /
    • 제23권5호
    • /
    • pp.773-787
    • /
    • 2020
  • In the injection molding process, the controlling stability of products quality is a very important factor in terms of productivity. Even when the optimum process conditions for the desired product quality are applied, uncontrollable external factors such as ambient temperature and humidity cause inevitable changes in the state of the melt resin, mold temperature. etc. Therefore, it is very difficult to maintain prodcut quality. In this study, a system that learns the correlation between process variables and product weight through artificial neural networks and predicts process conditions for the target weight was established. Then, when a disturbance occurs in the injection molding process and fluctuations in the weight of the product occur, the stability control of the product quality was performed by ANN predicting a new process condition for the change of weight. In order to artificially generate disturbance in the injection molding process, controllable factors were selected and changed among factors not learned in the ANN model. Initially, injection molding was performed with a polypropylene having a melt flow index of 10 g/10min, and then the resin was replaced with a polypropylene having a melt floiw index of 33 g/10min to apply disturbance. As a result, when the disturbance occurred, the deviation of the weight was -0.57 g, resulting in an error of -1.37%. Using the control method proposed in the study, through a total of 11 control processes, 41.57 g with an error of 0.00% in the range of 0.5% deviation of the target weight was measured, and the weight was stably maintained with 0.15±0.07% error afterwards.

습식 다회선 초음파유량계의 특성평가 연구 (A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter)

  • 이동근;조용;고재명;박태진;박종호
    • 한국유체기계학회 논문집
    • /
    • 제16권4호
    • /
    • pp.5-9
    • /
    • 2013
  • An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.

Analysis and Design of Sliding Mode Control for a Single-Phase AC-DC Converter

  • Sawaengsinkasikit, Winyu;Tipsuwanporn, Vittaya;Tarasantisuk, Chanlit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2291-2294
    • /
    • 2003
  • In this paper, analysis and control design of ac-dc converter, normally nonlinear time-varying system, using sliding mode controller to achieve fast output voltage response, disturbance rejection and robust system in the presence of load variation are demonstrated. The objective of this method is to develop methodology for output voltage to be constant and input current sinusoidal that results in nearly unity power factor, respectively. In addition the converter can be also bidirectional power flow. Simulation results using Matlab/Simulink show the effectiveness of sliding mode control system compared with linear feedback controller to guarantee enhanced PF>0.98, THD<5%, and ripple output voltage is less than 1% at the maximum output power.

  • PDF

CFD 시뮬레이션 기반 초임계 LNG용 사인함수 PCHE 설계 (Design of sinusoidal shape channel PCHEs for supercritical LNG based on CFD simulation)

  • 판진싱;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.69-76
    • /
    • 2021
  • Printed circuit heat exchanger (PCHE) is a compact heat exchanger with good heat transfer performance, high structure integrity, and reliability over a wide range of temperatures and pressures. Instead of the traditional zigzag and straight shape channel, the sinusoidal shape channel was adopted in this study to investigate the relation of thermal-hydraulic performance and waviness factors (period and amplitude). The local flow characteristics and the heat flux distribution were compared to verify the effects of period and amplitude on heat transfer performance. As the period of channel becomes shorter, the rapid change of the flow direction can produce high flow separation around the corner leading to the disturbance of the boundary layer opposite wall. The nonuniform distribution of flow velocity appeared around the corner positions can promote fluid mixing and lead to higher thermal performance. An evaluation index was used to compare the comprehensive performance of PCHE considering the Nusselt number and Fanning factor. Based on the simulation results, the optimal design parameters of PCHE channel shape were found that the channel with an equivalent bending angle of 15° offers the highest heat flux capacity.