DOI QR코드

DOI QR Code

Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header

주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책

  • Published : 2005.08.01

Abstract

Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.

Keywords

References

  1. 김연환, 1996, '발전소의 대형 주증기관의 진동특성', 한국소음진동공학회논문집, 제 6권, 제 6 호, pp. 709- 716
  2. Wang, T., Sun, Y. S., 1988, 'Dynamic Response of Piping System Subject to Flow Acoustic Excitation', ASME/ ANS Joint Nuclear Power Conference, pp. 51 -59
  3. Gibert, R. J.. Axisa, B. F. and Villard, 1978, 'Flow Induced Vibrations of Piping System', KESWICK-U.K, pp.617-631
  4. Walter W. von Nimitz, 'Low Frequency Vibrations at Centrifugal Plants', Proceedings of the Fourth Turbo-machinery Symposium, pp. 47 -54
  5. 한전전력연구원, 1996, '발전소배관과도진동 연구 최종보고서(KEPRI-93GS03) '

Cited by

  1. A Study on the Measurement of the Pipeline Displacement Vibration Using Accelerometers vol.24, pp.6, 2014, https://doi.org/10.5050/KSNVE.2014.24.6.476
  2. Structural Integrity Evaluation of Large Main Steam Piping by Water Hammering vol.36, pp.9, 2012, https://doi.org/10.3795/KSME-A.2012.36.9.1103