• 제목/요약/키워드: Flow Measuring

검색결과 1,316건 처리시간 0.023초

골막 자극 후 Laser Doppler Flowmetry를 이용한 치은혈류량 변화 (A laser Doppler study of gingival blood flow change following periosteal stimulation)

  • 이지영;김병옥
    • Journal of Periodontal and Implant Science
    • /
    • 제33권2호
    • /
    • pp.139-147
    • /
    • 2003
  • The roots of teeth exposed by gingival recession, may be successfully covered by various type of gingival grafting procedures. Vascularization of the recipient site is an essential determinant of the grafts' survival during the first healing stages. It has been suggested that a procedure by which they stimulate the periosteum presurgically will induce the proliferation of neo-endothelium in the site to be operated. The purpose of this study is to evaluate the variations in the gingival blood flow during 4weeks after periosteal stimulation in patient scheduled to receive gingival grafts and to compare variations in the gingival blood flow between smoker and non-smoker. Laser Doppler Flowmetry(floLAB(R), Moor Instruments Ltd, England ; wave length = 780mm. Max. power =l.6mW) was used to measure the gingival blood flow. 112 sites of 68 male patients (32 smokers and 36 non-smoker), aged between 23 and 48 years (smoker : 24-44 years. mean=32.6, non-smoker : 23-48 years, mean=28.5) were monitored for the blood flow. Gingival blood flow measured at before periosteal stimulation, 1-, 2-, 3-, and 4-weeks after periosteal stimulation from 10 a.m. to 2 p.m. The difference of blood flow in each measuring time, each measuring site and between smokers and non-smokers were statistically analyzed by MANOVA. The results were as follows : (1) Blood flow stayed increased for 2 weeks, and then, it was a tendency to decrease(p<0.05). (2) There was no statistically significant difference of blood flow change between smokers and non-smokers. (3)The blood flow at middle site had lower than mesial and distal site during the measuring periods(p<0.05). The present study suggested that blood flow change following periosteal stimulation was significant difference, thus periosteal stimulation before gingival graft might induce favorable results in gingival recession patient.

선회유동 교란에 따른 벤투리 유량측정의 불확실성 해석 (Effect of Swirl Flow Disturbance on Uncertainty of Flow Rate Measurement by Venturi)

  • 이정호;윤석호;유청환;박상진;정장환
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.18-25
    • /
    • 2009
  • Venturi has long been an attractive method of measuring flow rate in a variety of engineering applications since pressure loss is relatively small compared with other measuring methods. The current study focuses on making detailed uncertainty estimations as the upstream flow disturbance affects uncertainty levels of the flow rate measurement. Upstream flow disturbance can be determined by 9 different swirl generators. Measurement uncertainty of flow rate has been estimated by a quantitative uncertainty analysis which is based on the ANSI/ASME PTC 19.1-2005 standard. The results of flow rate uncertainty analysis show that the case with systematic error has higher than that without systematic error. Especially the result with systematic error exhibits that the uncertainty of flow rate was gradually increased by swirl flow disturbance. The uncertainty of flow rate measurement can be mainly affected by differential pressure and discharge coefficient. Flow disturbance can be also reduced by increasing of the upstream straight length of Venturi.

유동안정화 장치가 홴 테스터의 성능에 미치는 영향 (Effects of Flow Settling Means on the Performance of Fan Tester)

  • 최영석;김덕수;윤준용
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.29-34
    • /
    • 2005
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics (CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

유동안정화 장치가 홴 테스터의 성능에 미치는 영향 (Effects of Flow Settling Means on the Performance of Fan Tester)

  • 최영석;김덕수;윤준용
    • 한국유체기계학회 논문집
    • /
    • 제9권4호
    • /
    • pp.43-48
    • /
    • 2006
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics(CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

VRFB를 위한 BOP 구성 및 BMS 기능구현에 관한 연구 (A Study on the Configuration of BOP and Implementation of BMS Function for VRFB)

  • 최정식;오승열;정동화;박병철
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.74-83
    • /
    • 2014
  • This paper proposes a study on the configuration of balancing of plant(BOP) and implementation of battery management system(BMS) functions for vanadium redox flow battery(VRFB) and propose a method consists of sensor and required design specifications BOP system configuration. And it proposes an method of the functions implementation and control algorithm of the BMS for flow battery. Functions of BMS include temperature control, the charge and discharge control, flow control, level control, state of charge(SOC) estimation and a battery protection through the sensor signal of BOP. Functions of BMS is implemented by the sensor signal, so it is recognized as a very important factor measurement accuracy of the data. Therefore, measuring a mechanical signal(flow rate, temperature, level) through the BOP test model, and the measuring an electrical signal(cell voltage, stack voltage and stack current) through the VRFB charge-discharge system and analyzes the precision of data in this paper. Also it shows a good charge-discharge test results by the SOC estimation algorithm of VRFB. Proposed BOP configuration and BMS functions implementation can be used as a reference indicator for VRFB system design.

경사계를 이용한 교대변위 계측에 관한 연구 (The Measurement of Lateral Displacement of Abutment Using a Inclinometer)

    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 춘계학술대회논문집
    • /
    • pp.82-90
    • /
    • 2000
  • The abutment of bridge on soft foundation makes lateral movement due to the settlement of back fill and lateral flow. To measure the displacement of such a abutment, there are a lot of indirect method for measurement such as survey of leveling or inclinometer gauge around the abutment. But all of them are not sufficient to confirm the ground behavior and measure the exact lateral behavior of structure. As making the structure and pile cooperatively by measuring the movement of lateral displacement, for measuring the abutment displacement precisely by using the incliinometer. In this work, we try to suggest efficient measuring method of abutment displacement and its application.

  • PDF

모세관내 과도유동현상을 이용한 비뉴턴유체의 점도측정 (Viscosity Measurement of Non-Newtonian Fluids Using the Transient Flow Phenomena in the Capillary Tube)

  • 조민태;서상호;유상신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.738-741
    • /
    • 2001
  • The purpose of the present study is to measure the viscosity of liquid in the capillary tube viscometer using the unsteady flow concept. The capillary tube viscometer is consisted of a small cylindrical reservoir, capillary tubes, and the mass flow rate measuring system interfaced with computer. Two capillary tubes with 1.152 and 3.002 mm I.D. are used to determine the diameter effects on the viscosity measurements. The instantaneous shear rate and gravitational driving force in the capillary tube are determined by measuring the mass flow rate through the capillary tube instantaneously. The measured viscosities of water and aqueous Separan solution are in good agreement with the reported experimental data.

  • PDF

열량형 질량유량계에 대한 압력과 비열 영향 (The Effects of Pressure and Specific Heat on the Performance of Thermal Mass Flowmeter)

  • 최용문;박경암;최해만;이기성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.109-113
    • /
    • 1999
  • Thermal mass flow meter (TMF) is used measuring the small mass flow rate of gases. Generally, flow rate measuring accuracy of TMF is $\pm2{\%}$ of full scale. TMF is manufactured for specified working pressure and specified working gas by customer. If it were applied for different working pressure and gases, flow rate measurement accuracy decreased dramatically. In this study, a TMF tested with three different gases and pressure range of 0.2 MPa to 1.0 MPa. Effect of specific heat cause to increase flow measurement error as much as ratio of specific heat compare with reference gas. Pressure change cause to increase flowrate measurement deviation about $-0.2{\%}$ as the working pressure decreased 0.1 MPa.

  • PDF

Experimental and Computational Study on Separation Control Performance of Synthetic Jets with Circular Exit

  • Kim, Minhee;Lee, Byunghyun;Lee, Junhee;Kim, Chongam
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권3호
    • /
    • pp.296-314
    • /
    • 2016
  • This paper presents experimental and computational investigations of synthetic jets with a circular exit for improving flow control performance. First, the flow feature and vortex structure of a multiple serial circular exit were numerically analyzed from the view point of flow control effect under a cross flow condition. In order to improve separation control performance, experimental and numerical studies were conducted according to several key parameters, such as hole diameter, hole gap, the number of hole, jet array, and phase difference. Experiments were carried out in a quiescent condition and a forced separated flow condition using piezoelectrically driven synthetic jets. Jet characteristics were compared by measuring velocity profiles and pressure distributions. The interaction of synthetic jets with a freestream was examined by analyzing vortical structure characteristics. For separation control performance, separated flow over an airfoil at high angles of attack was employed and the flow control performance of the proposed synthetic jet was verified by measuring aerodynamic coefficient. The circular exit with a suitable hole parameter provides stable and persistent jet vortices that do beneficially affect separation control. This demonstrates the flow control performance of circular exit array could be remarkably improved by applying a set of suitable hole parameters.

정상유동 장치에서 유동 특성 평가 방법에 대한 연구(5) - 평가위치의 영향 (Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(5)-Effect of Evaluation Position)

  • 조시형;엄인용
    • 한국자동차공학회논문집
    • /
    • 제25권2호
    • /
    • pp.179-189
    • /
    • 2017
  • This paper is the fifth investigation on the methods of evaluating flow characteristics in a steady flow bench. In previous studies, several assumptions used in the steady flow bench were examined and it was concluded that the assumption of the solid rotation may lead to serious problems. In addition, though the velocity profiles were improved as the measuring position went downstream, the distributions were far from ideal regardless of the valve angle and evaluation position. The eccentricities were also not sufficiently small to disregard the effect on impulse swirl meter (ISM) measurement. Therefore, the effect of these distribution and eccentricity changes according to the positions needs to be analyzed to discuss the method of flow characteristics estimation. In this context, the effects of evaluation position on the steady flow characteristics were studied. For this purpose, the swirl coefficient and swirl ratio were assessed and compared via measurement of the conventional ISM and calculation based on the velocity by particle image velocimetry(PIV) from 1.75B, 1.75 times bore position apart from the cylinder head, to the 6.00B position. The results show that the swirl coefficients by ISM strictly decrease and the curves as a function of the valve lift become smooth and linear as the measuring position goes downstream. However, the values through the calculation based on the PIV are higher at the farther position due to the approach of the tangential velocity profile to ideal. In addition, there exists an offset effect between the velocity distribution and eccentricity in the low valve lift range when the coefficients are estimated based on the swirl center. Finally, the curve of the swirl ratio by ISM and by PIV evaluation as a function the measuring position intersect around 5.00B plane except at $26^{\circ}$ valve angle.