• 제목/요약/키워드: Floor Temperature

검색결과 471건 처리시간 0.032초

공동주택의 하절기 자연환기 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석 (Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the Top Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Opened -)

  • 최동호
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.45-55
    • /
    • 2005
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature, globe temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample units on the condition that all the openings of the units are opened. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained three brief results as follows. Indoor air temperature difference between the two sample units shifts a day. Indoor air temperature at the top floor unit is $0{\sim}1.8^{\circ}C$ higher than that of the middle floor unit from 12:00 p.m. to 12:00 a.m. and $0{\sim}2.8^{\circ}C$ lower from 12:00 a.m. to 12:00 p.m. The evaluation of the indoor thermal comfort index and the globe temperature shows similar results as the indoor air temperature measuring. Results of this experiment verified the actual existence of indoor air temperature difference between the top floor unit and the middle one and this difference comes from the heat storage of the roof.

컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성 (Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House)

  • 조동현
    • 한국기계가공학회지
    • /
    • 제21권2호
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.

온돌난방에서 노인과 청년의 피부온 반응 비교 (Thermoregulatory Responses in the Elderly and the Young under the Ondol System)

  • 정유정;최정화
    • 한국의류학회지
    • /
    • 제22권1호
    • /
    • pp.149-158
    • /
    • 1998
  • The purpose of this study was to investigate the effect of age on the human thermoregulatory responses and to obtain the basic information of the Korean thermophysiological characteristics under the traditional Korean floor heating system-Ondol. The participants consisted of 10 elderly women, 4 elderly men(over 65 years), 10 young women and 5 young men(in twenties). They were exposed to temperature-controlled Ondol room(20$\pm$1$^{\circ}C$, 50$\pm$5%R.H., floor surface temperature: 30$\pm$1$^{\circ}C$) for 60 minutes and wore the same experimental clothing. The postures were performed sitting and supine on the floor. In each pose, rectal temperature, skin.temperature of 10 areas, mean skin temperature, clothing microclimate, body fat were measured. The results were as follows; 1. The rectal temperature gradually decreased and mean skin temperature gradually increased in young and old groups in both supine and sitting pose on heated Ondol floor for 60 minutes. 2. Rectal temperature was different in each pose. The rectal temperature decreased 0.1$^{\circ}C$ in both groups under the condition of sitting and decreased 0.2'c in elderly group under the condition of supine. In supine pose, elderly group was more declined than young group. Mean skin temperature increased 0.5$^{\circ}C$ in both poses, both groups.

  • PDF

비정질 강섬유 혼입 바닥난방시스템의 열성능 평가 (Thermal performance prediction of amorphous steel fibers mixed into the floor heating system)

  • 조현;방승기
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.130-135
    • /
    • 2016
  • 본 연구에서는 비정질 강섬유 혼입 바닥몰탈을 이용한 바닥난방시스템과 일반 몰탈을 사용한 바닥난방시스템의 열성능을 비교 평가하기 위하여 시뮬레이션을 실시하였다. 시뮬레이션은 온수공급온도를 변화시켰으며 다음과 같은 결론을 얻었다. 바닥의 표면온도, 실내의 공기온도 등을 검토 결과 강섬유온돌을 사용할 경우에는 실내공기를 기준으로 하면 강섬유온돌이 일반온돌에 비해 7~9%에 가까운 열효율이 상승되었으며, 바닥의 온도를 기준으로 하면 2~4% 온도상승이 일어나는 것으로 나타났다.

사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험 (Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

바닥 복사 난방시 바닥온도와 거주자 자세 변화에 따른 인체 반응에 관한 연구 (The Study of Human Response for Floor Surface Temperature and Resident's Posture Change)

  • 김동규;김세환
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.846-851
    • /
    • 2012
  • The radiant floor heating system is traditional heating system in korea. Radiant floor heating is small in vertical temperature difference, air stream and radiant heat distribution is uniform. And radiant floor heating system provide thermal comfort conditions to the a resident. This study was undertaken to evaluate the physiological-subjective responses of the resident's posture change such as sitting and standing. The experimental investigations were carried out in climate chamber, and subjects were 4 college-age students in good health. The physiological response was skin temperature and subjective response was undertaken survey of TSV and CSV. The results were summarized as follows; The comfortable temperature range of plantar surface was $35.1{\sim}38.9^{\circ}C$ and buttock surface was $37.8{\sim}39.3^{\circ}C$.

난방부하와 온수온돌의 방열성능을 고려한 적정 공급온수온도 산출방법에 관한 연구 (A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel)

  • 최정민;이규남;류성룡;김용이;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.795-800
    • /
    • 2006
  • A common approach to achieve better thermal comfort with hydronic radiant floor heating system is supply water temperature control. This is the control method through which supply water temperature is varied with outdoor temperature. In this study, a comprehensive, yet simple calculation method to find optimum supply water temperature is evaluated by combining heat loss from the building and heat emission from the hydronic radiant floor heating system. And then the control performance of suggested calculation method is confirmed through experiment. It is shown that indoor air temperature is stably maintained around the set point.

  • PDF

바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구 (A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

Microstructures and Properties of Molybdenum Wire Doped with Minim $La_2O_3$

  • Li, DaCheng;Bu, Chunyang;Zhu, Yong-An;Wang, Jin
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1015-1016
    • /
    • 2006
  • The microstructures and properties of pure molybdenum wire and $Mo-La_2O_3$ alloy wire annealed at different temperatures are investigated systematically in this paper. It is shown that the recrystallization temperature, toughness and strength at room temperature of this wire was increased greatly by addition of $La_2O_3$. The room temperature embrittlement of this wire annealed at high temperature is improved remarkably.

  • PDF