Browse > Article
http://dx.doi.org/10.5855/ENERGY.2016.25.3.130

Thermal performance prediction of amorphous steel fibers mixed into the floor heating system  

Cho, Hyun (Research & Engineering Division, R&D CENTER, POSCO E&C)
Pang, Seung-Ki (Department of Architecture, Kyungmin College)
Publication Information
Abstract
The thermal performance of amorphous steel fibers mixed floor heating system was evaluated. Analysis of results, depending on the hot water supply temperature changes, the average temperature of the bottom of the hot water supply temperature is an amorphous steel fiber floor heating system is about 2~4% higher. The average temperature of the floor surface to 1.5m air amorphous steel fiber system is 1~2% higher. The amount of heat supplied to indoor air (1.5m) from the bottom surface of amorphous steel fiber floor heating system is about 7~8% higher
Keywords
Amorphous Steel Fiber; Heat transfer; Floor heating system; CFD;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Jung Hae-Kwon, Cho Dong-Woo, Yu Ki-Hyung, 2009, "Comparative Analysis on the Heat Transfer Characteristics between Dry and Wet Ondol Systems", Journal of the Architectural Institute of Korea, Vol. 25, No. 11, pp.315-322.
2 Lee Tai-Gang, Lee Ju-Yeob, Song Min-Jeong, Kim Sun-Woo, 2013, "The comparison of thermal characteristics of new Han-ok floor heating for applying modern On-dol system", Journal of the Korea Institute of Ecological Architecture and Environment, Vol. 13, No. 3, pp.61-69.
3 Ahn Byung-Wook, 1997, "Ondol Heated Room & its Indoor Thermal Environment", Journal of the Korean Society of Living Environment System, Vol. 4, No. 3, pp.1-12.
4 Yoon Yong-Jin, Park Sang-Dong, Sohn Jang-Yeul, 1984, "Effect of an Asymmetric Radiation Field on Thermal Sensation with Radiant Heating" Journal of the Architectural Institute of Korea, Vol. 4, No. 2, pp.139-142.
5 Chung Kwang-Seop, ,1998, "A Study on the Assessment of Local Thermal Sensation in Human Body by Varying Ondol Floor Surface Temperature" Jounal of the Korean Society of Living Environment System, Vol. 5, No. 2, pp.33-38.
6 Lim Jae-Han, Song Jin-Hee, Koo Bo-Kyoung, Song Seung-Yeong, Seong Yoon-Bok, 2012, "Characteristic of Thermal Output of Thermally Activated Building System During the Heating Operation According to FDM Analysis", Society of Air-conditioning and refrigerating engineers of Korea, pp.218-223.
7 Choi Jeong-Min, Lee Kyu-Nam, Ryu Seong-Ryoung, Kim Yong-Yee, Yeo Myoung-Souk, Kim Kwang-Woo, 2006, "A Study on the Method of Estimating Optimum Supply Water Temperature Considering the Heating Load and the Heat Emission Performance of Radiant Floor Heating Panel" Society of Air-conditioning and refrigerating engineers of Korea, pp.795-800.
8 Choi Jeong-Min, Lee Kyu-Nam, Ryu Seong-Ryoung, Kim Yong-Yee, Yeo Myoung-Souk, Kim Kwang-Woo, 2007, "A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System" Society of Air-conditioning and refrigerating engineers of Korea, Vol. 19, No. 1, pp.77-85.
9 Sohn Jang-Yeul, Chung Kwang-Seop, Ahn Byung-Wook, 1990, "An Experimental Results of the Transient Temperature Response of a Floor Heating Panel according to Varying Pipe Embedding Depth" Journal of the Architectural Institute of Korea, Vol. 6, No. 5, pp.185-191.
10 Song Gook-Sup, 2005, "Effects of the Floor Surface Temperature and Metabolism on Scrotal Temperature" Journal of the Korean Society of Living Environment System, Vol. 12, No. 3, pp.185-191.
11 Oh Byoung-Chil, Lee Kun-Young, 1985, "A Study on the Heat Efficiency in Ondol Heating System by different Heat-Accumulation Material" Journal of the Architectural Institute of Korea, Vol. 5, No. 2, pp.295-298.