• Title/Summary/Keyword: Flooding time

Search Result 393, Processing Time 0.033 seconds

Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater (축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

Analysis of Unit Pollution Load on Highway runoff (고속도로 노면 강우유출 오염부하 원단위 산정)

  • Kang, Hee-Man;Lee, Doo-Jin;Bae, Woo-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.55-68
    • /
    • 2012
  • Impervious surface increase due to urbanization, one of the leading causes of pavement increased the runoff coefficient, peak flow, and reducing the infiltration flow and thereby causing flooding and river erosion is occurring in aquatic ecosystems are known to impair. This study aimed to classify use type of detailed land into the road, reststop, tollgates and etc. focused on major domestic highways, to understand the characteristics of rainfall runoff pollutants and to calculate applicable unit pollution load. Because of high runoff coefficient and short travel time to drainage. first flush occurred clearly. Average EMCs of runoff in the highway was investigated as TSS 108.47 mg / L, COD 28.16 mg / L, BOD 13.61 mg / L, TN 6.38 mg / L, TP 0.03 mg / L, Cu 118.17 ${\mu}g$ / L, Pb 345.3 ${\mu}g$ / L, Zn 349.47 ${\mu}g$ / L. Unit pollution loads calculated by detailed land use area of highways based on average annual rainfall, EMCs, applicable basin areas and etc. were 46.6 kg/km2/day of BOD, 1.4 kg/km2/day of TP, 8.81 kg / km2/day of TN and these were BOD 50.8%, TP 66.7%, TN 64.4%in comparison of the unit pollution loads which applies fallow land standards of the TMDL(Total Maximum Daily Load). It was considered that discharged loads can be excessively calculated in case highway non-point management plans based on unit pollution load of the current land standard.

Appropriateness analysis of design rainfall factors using the rainfall data of an inundated flood events (침수 홍수사상의 강우자료를 활용한 설계강우 요소의 적정성 분석)

  • Yu, Byeong-Wook;Kim, Seon-Ho;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.4
    • /
    • pp.237-247
    • /
    • 2020
  • The purpose of this study is to analyze whether design rainfall and hyetograph, which are the main elements of design rainfall, can properly reflect the those of observed rainfalls through inundated rainfall events. The target areas were selected at seven large cities with high damages regarding to the flooding. Comparative analysis between probability and observed rainfall shows that 57% of the cases, in which rainfall amount through the IDF curve is estimated lower than the observed rainfall, do not properly reflect the observed rainfalls. In particular, this trend is exacerbated by the cases in low return period and the rain type of typhoon or frontal rain. The comparative results of rainfall intensity formula showed that the Talbot and Japanese formula were stable in the short- and long-term return periods, respectively. The comparison of hyetograph results also showed that the Mononobe method properly reflects the maximum rainfall intensity and the Huff method properly reflects the shape of rainfall pattern.

Design and Effectiveness Analysis of prefabricated Storage-type infiltration facility (조립식 저류형 침투시설의 설계 및 공간적용 효과분석)

  • Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: This study has developed economical and environmentally friendly storage type infiltration facilities that securing storage space inside the infiltration facility. It focused on preventing flooding rainfall as well as securing more groundwater through rainwater infiltration that is valuable for the dry season. In addition, this study compares the installation cost of the storage-type infiltration facility to the cost of the conventional rainwater management facilities to demonstrate the economic efficiency of the storage-based infiltration facility. Method: Unit infiltration of this facility is calculated and when it was applied to a certain capacity, the amount of countermeasures are proposed in case study. Result: Unit infiltration of it is $0.2541m^3/hr$ and un it Temporary storage of it is $1.054m^3/m$. As a result, the infiltration effect of this facility is $1.306m^3/hr$. The cost was approximately 30% reduction in time to apply the storage type infiltration facility as compared with the case to apply the existing penetration of the facilities. Since the penetration of the existing facilities is smaller than that and it has much securing volume to process the same the amount of countermeasures. Therefore, it is determined that the cost significantly increases in material cost part. On the other hand, storage type infiltration facility is installed a small quantity because Unit Temporary storage and infiltration are bigger than that. So, it occurred to reduce material and installation costs.

Design and Implementation of Web Mail Filtering Agent for Personalized Classification (개인화된 분류를 위한 웹 메일 필터링 에이전트)

  • Jeong, Ok-Ran;Cho, Dong-Sub
    • The KIPS Transactions:PartB
    • /
    • v.10B no.7
    • /
    • pp.853-862
    • /
    • 2003
  • Many more use e-mail purely on a personal basis and the pool of e-mail users is growing daily. Also, the amount of mails, which are transmitted in electronic commerce, is getting more and more. Because of its convenience, a mass of spam mails is flooding everyday. And yet automated techniques for learning to filter e-mail have yet to significantly affect the e-mail market. This paper suggests Web Mail Filtering Agent for Personalized Classification, which automatically manages mails adjusting to the user. It is based on web mail, which can be logged in any time, any place and has no limitation in any system. In case new mails are received, it first makes some personal rules in use of the result of observation ; and based on the personal rules, it automatically classifies the mails into categories according to the contents of mails and saves the classified mails in the relevant folders or deletes the unnecessary mails and spam mails. And, we applied Bayesian Algorithm using Dynamic Threshold for our system's accuracy.

Disease Dispersal Gradients of Rice Blast from a Point Source (점접종원으로부터 벼 도열병 확산의 경사)

  • Kim Choong Hoe
    • Korean Journal Plant Pathology
    • /
    • v.3 no.2
    • /
    • pp.131-136
    • /
    • 1987
  • Rates of lesion development over time and disease gradients over distance for blast disease on the two rice varieties, Brazos and M-20 1 were significantly affected by two different cultural conditions, upland and flooded conditions. Flooding rice field plots lowered the rates of lesion increase and flattened the disease gradients for both varieties. Despite absence of statistically significant differences in the rate of lesion increase between four sampled distances from infection focus, rate of lesion development tended to be slightly greater as distance from the infection focus increases. Rate of lesion increase was greater with more susceptible variety M-201 than with Brazos. Disease gradient was steeper for M-201 than for Brazos. As blast disease progressed, disease gradients became flattened regardless of variety due to the infections originated from secondary foci. Between two empirical disease gradient models examined, Kiyosawa & Shiyomi model was fitted better over Gregory model. Rates of blast isopath movement under upland conditions were calculated as approximately 0.2m/day and 0.4 m/day for Brazos and M-201, respectively. The results in this study suggest that differences in varietal resistance to blast could be detected by measuring disease gradient as efficiently as by measuring infection rate.

  • PDF

Detection Method of Distributed Denial-of-Service Flooding Attacks Using Analysis of Flow Information (플로우 분석을 이용한 분산 서비스 거부 공격 탐지 방법)

  • Jun, Jae-Hyun;Kim, Min-Jun;Cho, Jeong-Hyun;Ahn, Cheol-Woong;Kim, Sung-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.203-209
    • /
    • 2014
  • Today, Distributed denial of service (DDoS) attack present a very serious threat to the stability of the internet. The DDoS attack, which is consuming all of the computing or communication resources necessary for the service, is known very difficult to protect. The DDoS attack usually transmits heavy traffic data to networks or servers and they cannot handle the normal service requests because of running out of resources. It is very hard to prevent the DDoS attack. Therefore, an intrusion detection system on large network is need to efficient real-time detection. In this paper, we propose the detection mechanism using analysis of flow information against DDoS attacks in order to guarantee the transmission of normal traffic and prevent the flood of abnormal traffic. The OPNET simulation results show that our ideas can provide enough services in DDoS attack.

An Energy-Efficient Protocol For Detecting Injurious Insect in Wireless Bio Sensor Networks (무선 바이오센서 네트워크에서 에너지 효율을 고려한 해충 감지 시스템을 구축하기 위한 프로토콜)

  • Yoo, Dae Hyun;Lee, Joo Sang;An, Beongku;Kim, Nam-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.2
    • /
    • pp.29-34
    • /
    • 2008
  • In this paper, we proposed a system protocol for detecting injurious insect to support energy saving transmission in wireless bio sensor networks. The main ideas and features of the system are as follows. First, the route establishment method which is based on the energy efficiency and stability by using time-division tree structure. Second, multi-hop direction-based data gatering structure. In this structure, the selected fading method is used to transmit packet via the established tree structure for supporting power saving and route lifetime efficiently. Finally, we can get the node power saving and reduce transmission delay, thus network lifetime and efficiency are improved. The performance evaluation of the proposed protocol is via OPNET(Optimized Network Engineering Tool).

  • PDF

A Study on the Liquid-level Sensors Using Splitting Ratio of Fiber-optic Directional Couplers (광섬유형 방향성 결합기의 광 분배비를 이용한 수위 센서 연구)

  • Sohn, Kyung-Rak;Key, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.846-851
    • /
    • 2010
  • A liquid-air interface sensing system using the flat end surfaces of a fused-silica fiber coupler has been demonstrated. The principle is based on the additional optical loss caused by changing the refractive index of the external material at the boundary of the end face made of a fiber. The immersion characteristics of this system with respect to the different splitting ratios of the couplers were investigated to determine the sensitivity when it responses to water and air. These experimental data are very useful for selecting the coupling ratio of a coupler in order to develop a multiple sensing probe system. In the proposed sensor structure, it can be emphasize that the sensing probe can be appropriately arrayed on the basis of splitting ratio of the coupler. As a result, it is expected that the proposed liquid-air interface sensors can also be applied to monitor flooding that occurs in multiple areas at the same time.

Load-balanced Topology Maintenance with Partial Topology Reconstruction (부분 토폴로지 재구성 기법을 적용한 부하 균형 토폴로지 유지)

  • Hong, Youn-Sik;Lim, Hwa-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12A
    • /
    • pp.1188-1197
    • /
    • 2010
  • A most important thing in a connected dominating set(CDS)-based routing in a wireless ad-hoc network is to select a minimum number of dominating nodes and then build a backbone network which is made of them. Node failure in a CDS is an event of non-negligible probability. For applications where fault tolerance is critical, a traditional dominating-set based routing may not be a desirable form of clustering. It is necessary to minimize the frequency of reconstruction of a CDS to reduce message overhead due to message flooding. The idea is that by finding alternative nodes within a restricted range and locally reconstructing a CDS to include them, instead of totally reconstructing a new CDS. With the proposed algorithm, the resulting number of dominating nodes after partial reconstruction of CDS is not changed and also its execution time is faster than well-known algorithm of construction of CDS by 20~40%. In the case of high mobility situation, the proposed algorithm gives better results for the performance metrics, packet receive ratio and energy consumption.